... ... @@ -744,7 +744,7 @@
744 744  * Source is ON: Upper current limit, A;
745 745  * Lock – a flag to block the error until the device is restarted.
746 746  
747 -If interlock loop breaks and its current , the “HVIL error” is generated. Error clears if interlock loop is being restored.
747 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.
748 748  
749 749  (% class="box warningmessage" %)
750 750  (((
... ... @@ -800,7 +800,7 @@
800 800  
801 801  To change the general error parameters, select the "Protections → Critical error" section:
802 802  
803 -[[image:1733328487101-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]
803 +[[image:1735224942262-497.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
804 804  
805 805  In this section:
806 806  
... ... @@ -808,7 +808,7 @@
808 808  * Delay before setting the error, millisecond;
809 809  * Delay before clearing the error, second;
810 810  * Lock – a flag to block the error until the device is restarted;
811 -* Check: <error> – a flags to enable check of corresponding errors.
811 +* Errors 1, 2 to ser – a flags to enable check of corresponding errors.
812 812  
813 813  The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
814 814  