Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:19

From version 13.3
edited by Admin
on 2024/12/26 14:55
Change comment: There is no comment for this version
To version 12.1
edited by Admin
on 2024/12/26 14:51
Change comment: Uploaded new attachment "1735224706573-347.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -397,7 +397,7 @@
397 397  
398 398  To change the protection parameters from short circuit, select the "Protections → Short circuit" section:
399 399  
400 -[[image:1735224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]
400 +[[image:1735224667621-969.png]]
401 401  
402 402  In this section:
403 403  
... ... @@ -405,6 +405,8 @@
405 405  ** Enable – a flag to enable the protection;
406 406  ** Maximum current, A;
407 407  ** Delay before setting the error, second;
408 +* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs;
409 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs;
408 408  * Delay before clearing the error, second;
409 409  * Lock – a flag to block the error until the device is restarted.
410 410  
... ... @@ -429,7 +429,7 @@
429 429  
430 430  To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section:
431 431  
432 -[[image:1735224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]
434 +[[image:1733328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
433 433  
434 434  In this section:
435 435  
... ... @@ -438,6 +438,8 @@
438 438  * Maximum contactor temperature, °C;
439 439  * Tolerant contactor temperature, °C;
440 440  * Delay before setting the error, second;
443 +* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs;
444 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs;
441 441  * Delay before clearing the error, second;
442 442  * Lock – a flag to block the error until the device is restarted.
443 443  
... ... @@ -733,18 +733,14 @@
733 733  
734 734  To change the HVIL measurement parameters, select the "Protections → HVIL" section:
735 735  
736 -[[image:1735224839441-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
740 +[[image:1733328487099-371.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]
737 737  
738 738  In this section:
739 739  
740 740  * Enable – a flag to enable the protection;
741 -* Source is OFF: Lower current limit, A;
742 -* Source is OFF: Upper current limit, A;
743 -* Source is ON: Lower current limit, A;
744 -* Source is ON: Upper current limit, A;
745 745  * Lock – a flag to block the error until the device is restarted.
746 746  
747 -If interlock loop breaks and its current , the “HVIL error” is generated. Error clears if interlock loop is being restored.
747 +If interlock loop breaks, the “HVIL error” is generated. Error clears if interlock loop is being restored.
748 748  
749 749  (% class="box warningmessage" %)
750 750  (((
1735224839441-185.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -20.1 KB
Content