Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:19

From version 13.2
edited by Admin
on 2024/12/26 14:55
Change comment: There is no comment for this version
To version 6.2
edited by Admin
on 2024/12/25 11:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,7 +12,7 @@
12 12  
13 13  To change the overcurrent protection of the battery, select the "Protections → Overcurrent" section:
14 14  
15 -[[image:1735224601506-488.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]
15 +[[image:1733328382376-958.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
16 16  
17 17  In this section:
18 18  
... ... @@ -44,11 +44,9 @@
44 44  
45 45  === Charge current limit ===
46 46  
47 -TBA
48 48  
49 49  === Discharge current limit ===
50 50  
51 -TBA
52 52  
53 53  === Undervoltage ===
54 54  
... ... @@ -56,7 +56,7 @@
56 56  
57 57  To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section:
58 58  
59 -[[image:1735224224155-829.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]
57 +[[image:1733328382380-760.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]
60 60  
61 61  In this section:
62 62  
... ... @@ -63,7 +63,6 @@
63 63  * Enable – a flag to enable the protection;
64 64  * Minimum cell voltage, V;
65 65  * Tolerant cell voltage, V;
66 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
67 67  * Delay before setting the error, millisecond;
68 68  * Delay before clearing the error, second;
69 69  * Lock – a flag to block the error until the device is restarted.
... ... @@ -89,7 +89,7 @@
89 89  
90 90  To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section:
91 91  
92 -[[image:1735224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]]
89 +[[image:1733328382382-607.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
93 93  
94 94  In this section:
95 95  
... ... @@ -96,9 +96,9 @@
96 96  * Enable – a flag to enable the protection;
97 97  * Maximum cell voltage, V;
98 98  * Tolerant cell voltage, V;
99 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
100 100  * Delay before setting the error, millisecond;
101 101  * Delay before clearing the error, second;
98 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated;
102 102  * Lock – a flag to block the error until the device is restarted.
103 103  
104 104  As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated.
... ... @@ -278,7 +278,7 @@
278 278  If there is the “Water” error, the **“Critical error”** is generated and **all relays open**.
279 279  )))
280 280  
281 -=== Logic high temperature ===
278 +=== High Logic temperature ===
282 282  
283 283  To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section:
284 284  
... ... @@ -397,7 +397,7 @@
397 397  
398 398  To change the protection parameters from short circuit, select the "Protections → Short circuit" section:
399 399  
400 -[[image:1735224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]
397 +[[image:1733328415733-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="210" width="800"]]
401 401  
402 402  In this section:
403 403  
... ... @@ -405,6 +405,8 @@
405 405  ** Enable – a flag to enable the protection;
406 406  ** Maximum current, A;
407 407  ** Delay before setting the error, second;
405 +* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs;
406 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs;
408 408  * Delay before clearing the error, second;
409 409  * Lock – a flag to block the error until the device is restarted.
410 410  
... ... @@ -429,7 +429,7 @@
429 429  
430 430  To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section:
431 431  
432 -[[image:1735224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]
431 +[[image:1733328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
433 433  
434 434  In this section:
435 435  
... ... @@ -438,6 +438,8 @@
438 438  * Maximum contactor temperature, °C;
439 439  * Tolerant contactor temperature, °C;
440 440  * Delay before setting the error, second;
440 +* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs;
441 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs;
441 441  * Delay before clearing the error, second;
442 442  * Lock – a flag to block the error until the device is restarted.
443 443  
... ... @@ -508,10 +508,6 @@
508 508  If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.**
509 509  )))
510 510  
511 -=== Power fault ===
512 -
513 -TBA
514 -
515 515  === Charge contactor cycles ===
516 516  
517 517  The BMS Main 3 device protects the charging contactor against frequent switching.
... ... @@ -733,18 +733,14 @@
733 733  
734 734  To change the HVIL measurement parameters, select the "Protections → HVIL" section:
735 735  
736 -[[image:1735224839441-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
733 +[[image:1733328487099-371.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]
737 737  
738 738  In this section:
739 739  
740 740  * Enable – a flag to enable the protection;
741 -* Source is OFF: Lower current limit, A;
742 -* Source is OFF: Upper current limit, A;
743 -* Source is ON: Lower current limit, A;
744 -* Source is ON: Upper current limit, A;
745 745  * Lock – a flag to block the error until the device is restarted.
746 746  
747 -If interlock loop breaks and its curre, the “HVIL error” is generated. Error clears if interlock loop is being restored.
740 +If interlock loop breaks, the “HVIL error” is generated. Error clears if interlock loop is being restored.
748 748  
749 749  (% class="box warningmessage" %)
750 750  (((
1735224224155-829.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -23.4 KB
Content
1735224377252-473.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -23.4 KB
Content
1735224601506-488.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
1735224667621-969.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -32.8 KB
Content
1735224706573-347.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -22.1 KB
Content
1735224839441-185.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -20.1 KB
Content