Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,7 +12,7 @@ 12 12 13 13 To change the overcurrent protection of the battery, select the "Protections → Overcurrent" section: 14 14 15 -[[image:173 5224601506-488.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]15 +[[image:1733328382376-958.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 16 16 17 17 In this section: 18 18 ... ... @@ -397,7 +397,7 @@ 397 397 398 398 To change the protection parameters from short circuit, select the "Protections → Short circuit" section: 399 399 400 -[[image:173 5224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]400 +[[image:1733328415733-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="210" width="800"]] 401 401 402 402 In this section: 403 403 ... ... @@ -405,6 +405,8 @@ 405 405 ** Enable – a flag to enable the protection; 406 406 ** Maximum current, A; 407 407 ** Delay before setting the error, second; 408 +* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs; 409 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs; 408 408 * Delay before clearing the error, second; 409 409 * Lock – a flag to block the error until the device is restarted. 410 410 ... ... @@ -429,7 +429,7 @@ 429 429 430 430 To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section: 431 431 432 -[[image:173 5224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]434 +[[image:1733328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 433 433 434 434 In this section: 435 435 ... ... @@ -438,6 +438,8 @@ 438 438 * Maximum contactor temperature, °C; 439 439 * Tolerant contactor temperature, °C; 440 440 * Delay before setting the error, second; 443 +* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs; 444 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs; 441 441 * Delay before clearing the error, second; 442 442 * Lock – a flag to block the error until the device is restarted. 443 443
- 1735224706573-347.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.1 KB - Content
- 1735224839441-185.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.1 KB - Content