Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,7 +12,7 @@ 12 12 13 13 To change the overcurrent protection of the battery, select the "Protections → Overcurrent" section: 14 14 15 -[[image:173 5224601506-488.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]15 +[[image:1733328382376-958.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 16 16 17 17 In this section: 18 18 ... ... @@ -42,14 +42,6 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 -=== Charge current limit === 46 - 47 -TBA 48 - 49 -=== Discharge current limit === 50 - 51 -TBA 52 - 53 53 === Undervoltage === 54 54 55 55 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -56,7 +56,7 @@ 56 56 57 57 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 58 58 59 -[[image:173 5224224155-829.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]51 +[[image:1733328382380-760.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]] 60 60 61 61 In this section: 62 62 ... ... @@ -63,7 +63,6 @@ 63 63 * Enable – a flag to enable the protection; 64 64 * Minimum cell voltage, V; 65 65 * Tolerant cell voltage, V; 66 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 67 67 * Delay before setting the error, millisecond; 68 68 * Delay before clearing the error, second; 69 69 * Lock – a flag to block the error until the device is restarted. ... ... @@ -89,7 +89,7 @@ 89 89 90 90 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 91 91 92 -[[image:173 5224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]]83 +[[image:1733328382382-607.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 93 93 94 94 In this section: 95 95 ... ... @@ -96,9 +96,9 @@ 96 96 * Enable – a flag to enable the protection; 97 97 * Maximum cell voltage, V; 98 98 * Tolerant cell voltage, V; 99 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 100 100 * Delay before setting the error, millisecond; 101 101 * Delay before clearing the error, second; 92 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 102 102 * Lock – a flag to block the error until the device is restarted. 103 103 104 104 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -278,7 +278,7 @@ 278 278 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 279 279 ))) 280 280 281 -=== Logic hightemperature ===272 +=== High Logic temperature === 282 282 283 283 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 284 284 ... ... @@ -397,7 +397,7 @@ 397 397 398 398 To change the protection parameters from short circuit, select the "Protections → Short circuit" section: 399 399 400 -[[image:173 5224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]391 +[[image:1733328415733-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="210" width="800"]] 401 401 402 402 In this section: 403 403 ... ... @@ -405,6 +405,8 @@ 405 405 ** Enable – a flag to enable the protection; 406 406 ** Maximum current, A; 407 407 ** Delay before setting the error, second; 399 +* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs; 400 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs; 408 408 * Delay before clearing the error, second; 409 409 * Lock – a flag to block the error until the device is restarted. 410 410 ... ... @@ -429,7 +429,7 @@ 429 429 430 430 To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section: 431 431 432 -[[image:173 5224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]425 +[[image:1733328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 433 433 434 434 In this section: 435 435 ... ... @@ -438,6 +438,8 @@ 438 438 * Maximum contactor temperature, °C; 439 439 * Tolerant contactor temperature, °C; 440 440 * Delay before setting the error, second; 434 +* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs; 435 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs; 441 441 * Delay before clearing the error, second; 442 442 * Lock – a flag to block the error until the device is restarted. 443 443 ... ... @@ -508,10 +508,6 @@ 508 508 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 509 509 ))) 510 510 511 -=== Power fault === 512 - 513 -TBA 514 - 515 515 === Charge contactor cycles === 516 516 517 517 The BMS Main 3 device protects the charging contactor against frequent switching.
- 1735224224155-829.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.4 KB - Content
- 1735224377252-473.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.4 KB - Content
- 1735224601506-488.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.6 KB - Content
- 1735224667621-969.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.8 KB - Content
- 1735224706573-347.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.1 KB - Content