... ... @@ -733,14 +733,18 @@ 733 733 734 734 To change the HVIL measurement parameters, select the "Protections → HVIL" section: 735 735 736 -[[image:173 3328487099-371.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]736 +[[image:1735224839441-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] 737 737 738 738 In this section: 739 739 740 740 * Enable – a flag to enable the protection; 741 +* Source is OFF: Lower current limit, A; 742 +* Source is OFF: Upper current limit, A; 743 +* Source is ON: Lower current limit, A; 744 +* Source is ON: Upper current limit, A; 741 741 * Lock – a flag to block the error until the device is restarted. 742 742 743 -If interlock loop breaks, the “HVIL error” is generated. Error clears if interlock loop is being restored. 747 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored. 744 744 745 745 (% class="box warningmessage" %) 746 746 ((( ... ... @@ -796,7 +796,7 @@ 796 796 797 797 To change the general error parameters, select the "Protections → Critical error" section: 798 798 799 -[[image:173 3328487101-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]803 +[[image:1735224942262-497.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] 800 800 801 801 In this section: 802 802 ... ... @@ -804,7 +804,7 @@ 804 804 * Delay before setting the error, millisecond; 805 805 * Delay before clearing the error, second; 806 806 * Lock – a flag to block the error until the device is restarted; 807 -* Check: <error>– a flags to enable check of corresponding errors.811 +* Errors 1, 2 to ser – a flags to enable check of corresponding errors. 808 808 809 809 The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 810 810
- 1735224839441-185.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.1 KB - Content
- 1735224942262-497.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content