... ... @@ -733,14 +733,18 @@
733 733  
734 734  To change the HVIL measurement parameters, select the "Protections → HVIL" section:
735 735  
736 -[[image:1733328487099-371.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]
736 +[[image:1735224839441-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
737 737  
738 738  In this section:
739 739  
740 740  * Enable – a flag to enable the protection;
741 +* Source is OFF: Lower current limit, A;
742 +* Source is OFF: Upper current limit, A;
743 +* Source is ON: Lower current limit, A;
744 +* Source is ON: Upper current limit, A;
741 741  * Lock – a flag to block the error until the device is restarted.
742 742  
743 -If interlock loop breaks, the “HVIL error” is generated. Error clears if interlock loop is being restored.
747 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.
744 744  
745 745  (% class="box warningmessage" %)
746 746  (((
... ... @@ -796,7 +796,7 @@
796 796  
797 797  To change the general error parameters, select the "Protections → Critical error" section:
798 798  
799 -[[image:1733328487101-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]
803 +[[image:1735224942262-497.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
800 800  
801 801  In this section:
802 802  
... ... @@ -804,7 +804,7 @@
804 804  * Delay before setting the error, millisecond;
805 805  * Delay before clearing the error, second;
806 806  * Lock – a flag to block the error until the device is restarted;
807 -* Check: <error> – a flags to enable check of corresponding errors.
811 +* Errors 1, 2 to ser – a flags to enable check of corresponding errors.
808 808  
809 809  The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
810 810  
1735224839441-185.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +20.1 KB
Content
1735224942262-497.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content