Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:19

From version 12.1
edited by Admin
on 2024/12/26 14:51
Change comment: Uploaded new attachment "1735224706573-347.png", version {1}
To version 14.2
edited by Admin
on 2024/12/26 14:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -397,7 +397,7 @@
397 397  
398 398  To change the protection parameters from short circuit, select the "Protections → Short circuit" section:
399 399  
400 -[[image:1735224667621-969.png]]
400 +[[image:1735224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]
401 401  
402 402  In this section:
403 403  
... ... @@ -405,8 +405,6 @@
405 405  ** Enable – a flag to enable the protection;
406 406  ** Maximum current, A;
407 407  ** Delay before setting the error, second;
408 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs;
409 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs;
410 410  * Delay before clearing the error, second;
411 411  * Lock – a flag to block the error until the device is restarted.
412 412  
... ... @@ -431,7 +431,7 @@
431 431  
432 432  To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section:
433 433  
434 -[[image:1733328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
432 +[[image:1735224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]
435 435  
436 436  In this section:
437 437  
... ... @@ -440,8 +440,6 @@
440 440  * Maximum contactor temperature, °C;
441 441  * Tolerant contactor temperature, °C;
442 442  * Delay before setting the error, second;
443 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs;
444 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs;
445 445  * Delay before clearing the error, second;
446 446  * Lock – a flag to block the error until the device is restarted.
447 447  
... ... @@ -737,14 +737,18 @@
737 737  
738 738  To change the HVIL measurement parameters, select the "Protections → HVIL" section:
739 739  
740 -[[image:1733328487099-371.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]
736 +[[image:1735224839441-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
741 741  
742 742  In this section:
743 743  
744 744  * Enable – a flag to enable the protection;
741 +* Source is OFF: Lower current limit, A;
742 +* Source is OFF: Upper current limit, A;
743 +* Source is ON: Lower current limit, A;
744 +* Source is ON: Upper current limit, A;
745 745  * Lock – a flag to block the error until the device is restarted.
746 746  
747 -If interlock loop breaks, the “HVIL error” is generated. Error clears if interlock loop is being restored.
747 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.
748 748  
749 749  (% class="box warningmessage" %)
750 750  (((
... ... @@ -800,7 +800,7 @@
800 800  
801 801  To change the general error parameters, select the "Protections → Critical error" section:
802 802  
803 -[[image:1733328487101-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]
803 +[[image:1735224942262-497.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
804 804  
805 805  In this section:
806 806  
... ... @@ -808,7 +808,7 @@
808 808  * Delay before setting the error, millisecond;
809 809  * Delay before clearing the error, second;
810 810  * Lock – a flag to block the error until the device is restarted;
811 -* Check: <error> – a flags to enable check of corresponding errors.
811 +* Errors 1, 2 to ser – a flags to enable check of corresponding errors.
812 812  
813 813  The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
814 814  
1735224839441-185.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +20.1 KB
Content
1735224942262-497.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content