Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -397,7 +397,7 @@ 397 397 398 398 To change the protection parameters from short circuit, select the "Protections → Short circuit" section: 399 399 400 -[[image:1735224667621-969.png]] 400 +[[image:1735224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]] 401 401 402 402 In this section: 403 403 ... ... @@ -405,8 +405,6 @@ 405 405 ** Enable – a flag to enable the protection; 406 406 ** Maximum current, A; 407 407 ** Delay before setting the error, second; 408 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs; 409 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs; 410 410 * Delay before clearing the error, second; 411 411 * Lock – a flag to block the error until the device is restarted. 412 412 ... ... @@ -431,7 +431,7 @@ 431 431 432 432 To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section: 433 433 434 -[[image:173 3328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]432 +[[image:1735224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] 435 435 436 436 In this section: 437 437 ... ... @@ -440,8 +440,6 @@ 440 440 * Maximum contactor temperature, °C; 441 441 * Tolerant contactor temperature, °C; 442 442 * Delay before setting the error, second; 443 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs; 444 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs; 445 445 * Delay before clearing the error, second; 446 446 * Lock – a flag to block the error until the device is restarted. 447 447 ... ... @@ -737,14 +737,18 @@ 737 737 738 738 To change the HVIL measurement parameters, select the "Protections → HVIL" section: 739 739 740 -[[image:173 3328487099-371.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]736 +[[image:1735224839441-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] 741 741 742 742 In this section: 743 743 744 744 * Enable – a flag to enable the protection; 741 +* Source is OFF: Lower current limit, A; 742 +* Source is OFF: Upper current limit, A; 743 +* Source is ON: Lower current limit, A; 744 +* Source is ON: Upper current limit, A; 745 745 * Lock – a flag to block the error until the device is restarted. 746 746 747 -If interlock loop breaks, the “HVIL error” is generated. Error clears if interlock loop is being restored. 747 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored. 748 748 749 749 (% class="box warningmessage" %) 750 750 ((( ... ... @@ -800,7 +800,7 @@ 800 800 801 801 To change the general error parameters, select the "Protections → Critical error" section: 802 802 803 -[[image:173 3328487101-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]803 +[[image:1735224942262-497.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] 804 804 805 805 In this section: 806 806 ... ... @@ -808,7 +808,7 @@ 808 808 * Delay before setting the error, millisecond; 809 809 * Delay before clearing the error, second; 810 810 * Lock – a flag to block the error until the device is restarted; 811 -* Check: <error>– a flags to enable check of corresponding errors.811 +* Errors 1, 2 to ser – a flags to enable check of corresponding errors. 812 812 813 813 The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 814 814
- 1735224839441-185.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.1 KB - Content
- 1735224942262-497.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content