... ... @@ -397,7 +397,7 @@
397 397  
398 398  To change the protection parameters from short circuit, select the "Protections → Short circuit" section:
399 399  
400 -[[image:1735224667621-969.png]]
400 +[[image:1735224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]
401 401  
402 402  In this section:
403 403  
... ... @@ -405,8 +405,6 @@
405 405  ** Enable – a flag to enable the protection;
406 406  ** Maximum current, A;
407 407  ** Delay before setting the error, second;
408 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs;
409 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs;
410 410  * Delay before clearing the error, second;
411 411  * Lock – a flag to block the error until the device is restarted.
412 412  
... ... @@ -431,7 +431,7 @@
431 431  
432 432  To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section:
433 433  
434 -[[image:1733328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
432 +[[image:1735224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]
435 435  
436 436  In this section:
437 437  
... ... @@ -440,8 +440,6 @@
440 440  * Maximum contactor temperature, °C;
441 441  * Tolerant contactor temperature, °C;
442 442  * Delay before setting the error, second;
443 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs;
444 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs;
445 445  * Delay before clearing the error, second;
446 446  * Lock – a flag to block the error until the device is restarted.