BMS Main 2R can control up to 40 measuring modules and manage a battery consisting of 720 cells.

Note: BMS Main 2R and BMS Main 2RX are different products based on the same PCB while using different firmware. You can easily switch from BMS Main 2R to BMS Main 2RX by flashing the corresponding firmware.

Specifications

ParameterValue
Power supply
Supply voltage, V9 to 32
Current consumption at supply voltage 24 V, mA, max100
Scalability
Number of connected BMS Logic devices, max40
Number of controlled cells, max720
Controls
Number of programmable solid-state relays for contactors (55V, 3A)4
Number of programmable discrete inputs (dry contact)4
Number of programmable discrete outputs (+5V, total 200mA)4
Sensors
Number of connected current sensors (two signal lines for each sensor)2

Error in measuring signals from current sensors, V, max

At ambient temperature 25 ± 5 ºС

± 0.001
Current sensor types

Bidirectional with 5V supply voltage

(LEM series HASS, HTFS, DHAB or analogues)

Number of connected external temperature sensors (100 kOhm NTC-thermistors)2

Temperature measurement error using external temperature sensors, ºС, max

In the measurement range from -20 to +85 ºС

± 2
Interfaces
Number of USB interfaces1
USB speed, Mbit/s12
Number of CAN interfaces2
CAN speed, kbit/s125, 250 (by default), 500, 1000
Number of RS-485 interfaces2
RS-485 speed, bit/s600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
Output voltage of CAN power supply, V5.0 ± 0.5
Output current of CAN power supply, mA, max400
Number of Ethernet interfaces1
Ethernet speed, Mbps10/100
Connecting an additional expansion interface moduleBMS Wi-Fi, BMS GSM, BMS LANmodule
Headers X1, X8-X13 type Molex series Micro-Fit
Headers X2-X5 type Molex series Mini-Fit
Galvanic isolation

Rated insulation voltage, VRMS, min

Conditions: duration 1 minute, AC 50 Hz, 1) between connectors of CAN1, RS-485-1, discrete inputs/outputs interfaces and device power circuits, 2) between connectors of CAN1, RS-485-1, discrete inputs/outputs interfaces and high voltage measurement circuits, 3) between the device power supply circuits and the high voltage measurement circuits

3500
Weight and overall dimensions
Overall dimensions (length × weight × height), mm120 × 120 × 16
Weight, g, max100 ± 10
Operating conditions
Operating temperature range, °С-40 to +85

Overall and mounting dimensions ​​​​1774281980926-360.png