Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:04
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1. Technicalspecifications1 +1. General information - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main 2\.1.WebHome1 +drafts.BMS Main 2\.1.WebHome - Content
-
... ... @@ -1,23 +4,36 @@ 1 -(% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Technical specifications = 3 - 4 4 [[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]] 5 5 6 -BMS Main 2.1 is a modular BMScontrollerfor24-1200V batteries. It interacts withmeasuringmodules, calculatesthebatterystate,andprotectsthebatteryfromdamage.3 +The BMS Main 2.1 is a controller of the modular battery management system that has the following features: 7 7 8 -BMS based on the Main 2.1 can control up to 23 measuring modules and manage a battery consisting of 414 cells. 5 +* measuring current flowing through the battery; 6 +* communication with BMS Logic that measure voltage and temperature of the battery cells; 7 +* management of charging and discharging the battery; 8 +* management of balancing the battery cells; 9 +* protection of the battery from damage caused by current, voltage, temperature, etc.; 10 +* communication with external equipment (chargers, inverters, indication panels) to provide needed battery operation mode; 11 +* communication with external systems over Ethernet, CAN, RS-485, Wi-Fi; 12 +* collecting and storing battery history data on an SD card. 9 9 10 - ==Specifications==14 +The BMS Main 2.1 is used solely in civil areas. It does not use encryption and cryptography. 11 11 16 +The BMS Main 2.1 is a part of Movicom Electric BMS, a modular battery management system, and controls the following devices: 17 + 18 +* //BMS Logic 2.0//; 19 +* //BMS Logic 12//; 20 +* //BMS Logic 18//; 21 +* //BMS Logic RET//. 22 + 23 += 1.1 Specifications = 24 + 12 12 (% style="width:705px" %) 13 13 |(% style="width:434px" %)**Parameter**|(% style="width:267px" %)**Value** 14 -|(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9 to3027 +|(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9÷30 15 15 |(% style="width:434px" %)Current consumption @12 V, mA (max)|(% style="width:267px" %)100 16 16 |Number of BMS Logic devices|1 to 23 17 17 |Number of cells (maximum)|414 18 18 |(% style="width:434px" %)Number of programmable solid-state relays for contactors (55V, 3A)|(% style="width:267px" %)4 19 19 |(% style="width:434px" %)Number of programmable discrete inputs (dry contact)|(% style="width:267px" %)4 20 -|(% style="width:434px" %)Number of programmable discrete outputs (+5V , total 200mA)|(% style="width:267px" %)433 +|(% style="width:434px" %)Number of programmable discrete outputs (+5V)|(% style="width:267px" %)4 21 21 |(% style="width:434px" %)Current sensor type|(% style="width:267px" %)((( 22 22 Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS) 23 23 ))) ... ... @@ -26,21 +26,18 @@ 26 26 |(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000 27 27 |(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2 28 28 |(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 29 -|(% style="width:434px" %)CAN output voltage, V|(% style="width:267px" %)5.0 ± 0.5 30 -|(% style="width:434px" %)CAN output current, mA (maximum)|(% style="width:267px" %)400 31 -|(% style="width:434px" %)Number of Ethernet interfaces|(% style="width:267px" %)1 42 +|(% style="width:434px" %)**CAN output voltage, V**|(% style="width:267px" %)**5.0 ± 0.5** 43 +|(% style="width:434px" %)**CAN output current, mA (maximum)**|(% style="width:267px" %)400 44 +|(% style="width:434px" %)**Number of Ethernet interfaces**|(% style="width:267px" %)1 32 32 |(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100 33 33 |(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32 34 -|(% style="width:434px" %)Weight, g|(% style="width:267px" %)100 ± 10 35 -|(% style="width:434px" %)Operating temperature range, °С|(% style="width:267px" %)-40 to +85 47 +|(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5 48 +|(% colspan="2" style="width:702px" %)**Operating conditions** 49 +|(% style="width:434px" %)Operating temperature range, °С|(% style="width:267px" %)-40÷75 36 36 |(% style="width:434px" %)The degree of protection from external influences|(% style="width:267px" %)IP00 37 -|Headers P1, P6-P9 type |Molex series Mini-Fit 38 -|Headers P11-P15 type |Molex series Micro-Fit 39 39 40 -== Overall and mounting dimensions == 52 +== 1.2 Overall and mounting dimensions == 41 41 42 -[[image:1733138859908-160.png ||data-xwiki-image-style-alignment="center" height="403" width="458"]]54 +[[image:1733138859908-160.png]] 43 43 44 -[[image:1733138864828-321.png||data-xwiki-image-style-alignment="center" height="120" width="463"]] 45 - 46 - 56 +[[image:1733138864828-321.png]]