Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:04
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1. Technicalspecifications1 +1. General information - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 2\.1.WebHome1 +Controllers.BMS Main 2\.1.WebHome - Content
-
... ... @@ -1,45 +1,6 @@ 1 -(% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Technical specifications = 1 +This document describes configuration procedure of BMS Main 2.x board. Configuring can be done using the web interface available via Ethernet or Wi-Fi. 3 3 4 -[[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]] 5 5 6 -BMS Main 2.1 is a modular BMS controller for 24-1200V batteries. It interacts with measuring modules, calculates the battery state, and protects the battery from damage. 7 7 8 -BMS based on the Main 2.1 can control up to 23 measuring modules and manage a battery consisting of 414 cells. 9 9 10 -== 1.1 Specifications == 11 - 12 -(% style="width:705px" %) 13 -|(% style="width:434px" %)**Parameter**|(% style="width:267px" %)**Value** 14 -|(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9÷30 15 -|(% style="width:434px" %)Current consumption @12 V, mA (max)|(% style="width:267px" %)100 16 -|Number of BMS Logic devices|1 to 23 17 -|Number of cells (maximum)|414 18 -|(% style="width:434px" %)Number of programmable solid-state relays for contactors (55V, 3A)|(% style="width:267px" %)4 19 -|(% style="width:434px" %)Number of programmable discrete inputs (dry contact)|(% style="width:267px" %)4 20 -|(% style="width:434px" %)Number of programmable discrete outputs (+5V)|(% style="width:267px" %)4 21 -|(% style="width:434px" %)Current sensor type|(% style="width:267px" %)((( 22 -Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS) 23 -))) 24 -|(% style="width:434px" %)Current sensor signal measurement error, V (maximum)|(% style="width:267px" %)0.001 25 -|(% style="width:434px" %)Number of CAN interfaces|(% style="width:267px" %)1 26 -|(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000 27 -|(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2 28 -|(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 29 -|(% style="width:434px" %)CAN output voltage, V|(% style="width:267px" %)5.0 ± 0.5 30 -|(% style="width:434px" %)CAN output current, mA (maximum)|(% style="width:267px" %)400 31 -|(% style="width:434px" %)Number of Ethernet interfaces|(% style="width:267px" %)1 32 -|(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100 33 -|(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32 34 -|(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5 35 -|(% colspan="2" style="width:702px" %)**Operating conditions** 36 -|(% style="width:434px" %)Operating temperature range, °С|(% style="width:267px" %)-40÷75 37 -|(% style="width:434px" %)The degree of protection from external influences|(% style="width:267px" %)IP00 38 - 39 -== 1.2 Overall and mounting dimensions == 40 - 41 -[[image:1733138859908-160.png||data-xwiki-image-style-alignment="center" height="403" width="458"]] 42 - 43 -[[image:1733138864828-321.png||data-xwiki-image-style-alignment="center" height="120" width="463"]] 44 - 45 45
- 1733138859908-160.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -74.1 KB - Content
- 1733138864828-321.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.5 KB - Content