... ... @@ -1,11 +1,27 @@
1 1  [[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]]
2 2  
3 -BMS Main 2.1 is a modular BMS controller for 24-1200V batteries. It interacts with measuring modules, calculates the battery state, and protects the battery from damage.
3 +The BMS Main 2.1 is a controller of the modular battery management system that has the following features:
4 4  
5 -BMS based on the Main 2.1 can control up to 23 measuring modules and manage a battery consisting of 414 cells.
5 +* measuring current flowing through the battery;
6 +* communication with BMS Logic that measure voltage and temperature of the battery cells;
7 +* management of charging and discharging the battery;
8 +* management of balancing the battery cells;
9 +* protection of the battery from damage caused by current, voltage, temperature, etc.;
10 +* communication with external equipment (chargers, inverters, indication panels) to provide needed battery operation mode;
11 +* communication with external systems over Ethernet, CAN, RS-485, Wi-Fi;
12 +* collecting and storing battery history data on an SD card.
6 6  
7 -== 1.1 Specifications ==
14 +The BMS Main 2.1 is used solely in civil areas. It does not use encryption and cryptography.
8 8  
16 +The BMS Main 2.1 is a part of Movicom Electric BMS, a modular battery management system, and controls the following devices:
17 +
18 +* //BMS Logic 2.0//;
19 +* //BMS Logic 12//;
20 +* //BMS Logic 18//;
21 +* //BMS Logic RET//.
22 +
23 += 1.1 Specifications =
24 +
9 9  (% style="width:705px" %)
10 10  |(% style="width:434px" %)**Parameter**|(% style="width:267px" %)**Value**
11 11  |(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9÷30
... ... @@ -23,9 +23,9 @@
23 23  |(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000
24 24  |(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2
25 25  |(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
26 -|(% style="width:434px" %)CAN output voltage, V|(% style="width:267px" %)5.0 ± 0.5
27 -|(% style="width:434px" %)CAN output current, mA (maximum)|(% style="width:267px" %)400
28 -|(% style="width:434px" %)Number of Ethernet interfaces|(% style="width:267px" %)1
42 +|(% style="width:434px" %)**CAN output voltage, V**|(% style="width:267px" %)**5.0 ± 0.5**
43 +|(% style="width:434px" %)**CAN output current, mA (maximum)**|(% style="width:267px" %)400
44 +|(% style="width:434px" %)**Number of Ethernet interfaces**|(% style="width:267px" %)1
29 29  |(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100
30 30  |(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32
31 31  |(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5
... ... @@ -35,6 +35,6 @@
35 35  
36 36  == 1.2 Overall and mounting dimensions ==
37 37  
38 -[[image:1733138859908-160.png||data-xwiki-image-style-alignment="center"]]
54 +[[image:1733138859908-160.png]]
39 39  
40 -[[image:1733138864828-321.png||data-xwiki-image-style-alignment="center"]]
56 +[[image:1733138864828-321.png]]