Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1. Technicalspecifications1 +1. General information - Content
-
... ... @@ -1,11 +1,27 @@ 1 1 [[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]] 2 2 3 -BMS Main 2.1 is a modular BMScontrollerfor24-1200V batteries. It interacts withmeasuringmodules, calculatesthebatterystate,andprotectsthebatteryfromdamage.3 +The BMS Main 2.1 is a controller of the modular battery management system that has the following features: 4 4 5 -BMS based on the Main 2.1 can control up to 23 measuring modules and manage a battery consisting of 414 cells. 5 +* measuring current flowing through the battery; 6 +* communication with BMS Logic that measure voltage and temperature of the battery cells; 7 +* management of charging and discharging the battery; 8 +* management of balancing the battery cells; 9 +* protection of the battery from damage caused by current, voltage, temperature, etc.; 10 +* communication with external equipment (chargers, inverters, indication panels) to provide needed battery operation mode; 11 +* communication with external systems over Ethernet, CAN, RS-485, Wi-Fi; 12 +* collecting and storing battery history data on an SD card. 6 6 7 - ==1.1Specifications==14 +The BMS Main 2.1 is used solely in civil areas. It does not use encryption and cryptography. 8 8 16 +The BMS Main 2.1 is a part of Movicom Electric BMS, a modular battery management system, and controls the following devices: 17 + 18 +* //BMS Logic 2.0//; 19 +* //BMS Logic 12//; 20 +* //BMS Logic 18//; 21 +* //BMS Logic RET//. 22 + 23 += 1.1 Specifications = 24 + 9 9 (% style="width:705px" %) 10 10 |(% style="width:434px" %)**Parameter**|(% style="width:267px" %)**Value** 11 11 |(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9÷30 ... ... @@ -23,9 +23,9 @@ 23 23 |(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000 24 24 |(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2 25 25 |(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 26 -|(% style="width:434px" %)CAN output voltage, V|(% style="width:267px" %)5.0 ± 0.5 27 -|(% style="width:434px" %)CAN output current, mA (maximum)|(% style="width:267px" %)400 28 -|(% style="width:434px" %)Number of Ethernet interfaces|(% style="width:267px" %)1 42 +|(% style="width:434px" %)**CAN output voltage, V**|(% style="width:267px" %)**5.0 ± 0.5** 43 +|(% style="width:434px" %)**CAN output current, mA (maximum)**|(% style="width:267px" %)400 44 +|(% style="width:434px" %)**Number of Ethernet interfaces**|(% style="width:267px" %)1 29 29 |(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100 30 30 |(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32 31 31 |(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5 ... ... @@ -35,6 +35,6 @@ 35 35 36 36 == 1.2 Overall and mounting dimensions == 37 37 38 -[[image:1733138859908-160.png ||data-xwiki-image-style-alignment="center"]]54 +[[image:1733138859908-160.png]] 39 39 40 -[[image:1733138864828-321.png ||data-xwiki-image-style-alignment="center"]]56 +[[image:1733138864828-321.png]]