Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,40 +1,50 @@ 1 -[[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]] 1 +[[BMS Main 2.1 System controller>>image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]] 2 2 3 -BMS Main 2.1 is a modular BMScontrollerfor24-1200V batteries. It interacts withmeasuringmodules, calculatesthebatterystate,andprotectsthebatteryfromdamage.3 +The BMS Main 2.1b is a controller of the modular battery management system that has the following features: 4 4 5 -BMS based on the Main 2.1 can control up to 23 measuring modules and manage a battery consisting of 414 cells. 5 +* measuring current flowing through the battery; 6 +* communication with BMS Logic that measure voltage and temperature of the battery cells; 7 +* management of charging and discharging the battery; 8 +* management of balancing the battery cells; 9 +* protection of the battery from damage caused by current, voltage, temperature, etc.; 10 +* communication with external equipment (chargers, inverters, indication panels) to provide needed battery operation mode; 11 +* communication with external systems over Ethernet, CAN, RS-485, Wi-Fi; 12 +* collecting and storing battery history data on an SD card. 6 6 14 +The BMS Main 2.1b is used solely in civil areas. It does not use encryption and cryptography. 15 + 16 +The BMS Main 2.1b is a part of Movicom Electric BMS, a modular battery management system, and controls the following devices: 17 + 18 +* //BMS Logic 2.0//; 19 +* //BMS Logic 12//; 20 +* //BMS Logic 18//; 21 +* //BMS Logic RET//. 22 + 7 7 = 1.1 Specifications = 8 8 9 -(% style="width:705px" %) 10 -|(% style="width:434px" %)**Parameter**|(% style="width:267px" %)**Value** 11 -|(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9÷30 12 -|(% style="width:434px" %)Current consumption @12 V, mA (max)|(% style="width:267px" %)100 13 -|Number of BMS Logic devices|1 to 23 14 -|Number of cells (maximum)|414 15 -|(% style="width:434px" %)Number of programmable solid-state relays for contactors (55V, 3A)|(% style="width:267px" %)4 16 -|(% style="width:434px" %)Number of programmable discrete inputs (dry contact)|(% style="width:267px" %)4 17 -|(% style="width:434px" %)Number of programmable discrete outputs (+5V)|(% style="width:267px" %)4 18 -|(% style="width:434px" %)Current sensor type|(% style="width:267px" %)((( 25 +(% style="width:938px" %) 26 +|(% style="width:412px" %)**Parameter**|(% style="width:523px" %)**Value** 27 +|(% style="width:412px" %)Supply voltage, V|(% style="width:523px" %)9÷30 28 +|(% style="width:412px" %)Current consumption @12 V, mA (max)|(% style="width:523px" %)100 29 +|(% style="width:412px" %)Number of relays|(% style="width:523px" %)4 30 +|(% style="width:412px" %)Number of discrete inputs (dry contact)|(% style="width:523px" %)4 31 +|(% style="width:412px" %)Number of discrete outputs (+5V)|(% style="width:523px" %)4 32 +|(% style="width:412px" %)Relay 1-2 output voltage, V (max)|(% style="width:523px" %)55 33 +|(% style="width:412px" %)Relay 1-2 output current, A (max)|(% style="width:523px" %)2 34 +|(% style="width:412px" %)Relay 3-4 output voltage, V (max)|(% style="width:523px" %)55 35 +|(% style="width:412px" %)Relay 3-4 output current, A (max)|(% style="width:523px" %)8 36 +|(% style="width:412px" %)Current sensor type|(% style="width:523px" %)((( 19 19 Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS) 20 20 ))) 21 -|(% style="width:434px" %)Current sensor signal measurement error, V (maximum)|(% style="width:267px" %)0.001 22 -|(% style="width:434px" %)Number of CAN interfaces|(% style="width:267px" %)1 23 -|(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000 24 -|(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2 25 -|(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 26 -|(% style="width:434px" %)CAN output voltage, V|(% style="width:267px" %)5.0 ± 0.5 27 -|(% style="width:434px" %)CAN output current, mA (maximum)|(% style="width:267px" %)400 28 -|(% style="width:434px" %)Number of Ethernet interfaces|(% style="width:267px" %)1 29 -|(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100 30 -|(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32 31 -|(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5 32 -|(% colspan="2" style="width:702px" %)**Operating conditions** 33 -|(% style="width:434px" %)Operating temperature range, °С|(% style="width:267px" %)-40÷75 34 -|(% style="width:434px" %)The degree of protection from external influences|(% style="width:267px" %)IP00 39 +|(% style="width:412px" %)CAN bus speed, kbps|(% style="width:523px" %)125, 250 (by default), 500, 1000 40 +|(% style="width:412px" %)RS-485 baud rate, bps|(% style="width:523px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 41 +|(% style="width:412px" %)Ethernet speed, Mbps|(% style="width:523px" %)10/100 42 +|(% style="width:412px" %)RS-485 for communication with BMS Logic baud rate, bps|(% style="width:523px" %)115200 43 +|(% style="width:412px" %)Maximum number of the BMS Logic|(% style="width:523px" %)20 44 +|(% style="width:412px" %)Dimensions (length × width × height), mm|(% style="width:523px" %)120 × 120 × 32 45 +|(% style="width:412px" %)Weight, g|(% style="width:523px" %)100±5 46 +|(% colspan="2" style="width:935px" %)**Operating conditions** 47 +|(% style="width:412px" %)Operating temperature range, °С|(% style="width:523px" %)-40÷75 48 +|(% style="width:412px" %)The degree of protection from external influences|(% style="width:523px" %)IP00 35 35 36 -== 1.2 Overall and mounting dimensions == 37 - 38 -[[image:1733138859908-160.png]] 39 - 40 -[[image:1733138864828-321.png]] 50 +
- 1733138859908-160.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -74.1 KB - Content
- 1733138864828-321.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.5 KB - Content