Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:04
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1. General information1 +1. Technical specifications - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 2\.1.WebHome1 +Battery management systems.BMS Main 2\.1.WebHome - Content
-
... ... @@ -1,56 +1,46 @@ 1 +(% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Technical specifications = 3 + 1 1 [[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]] 2 2 3 - TheBMS Main 2.1 is a controllerof the modularbatterymanagementsystemthathasthe followingfeatures:6 +BMS Main 2.1 is a modular BMS controller for 24-1200V batteries. It interacts with measuring modules, calculates the battery state, and protects the battery from damage. 4 4 5 -* measuring current flowing through the battery; 6 -* communication with BMS Logic that measure voltage and temperature of the battery cells; 7 -* management of charging and discharging the battery; 8 -* management of balancing the battery cells; 9 -* protection of the battery from damage caused by current, voltage, temperature, etc.; 10 -* communication with external equipment (chargers, inverters, indication panels) to provide needed battery operation mode; 11 -* communication with external systems over Ethernet, CAN, RS-485, Wi-Fi; 12 -* collecting and storing battery history data on an SD card. 8 +BMS based on the Main 2.1 can control up to 23 measuring modules and manage a battery consisting of 414 cells. 13 13 14 - TheBMSMain 2.1 is used solely incivilareas. Itdoesnot useencryption and cryptography.10 +== Specifications == 15 15 16 -The BMS Main 2.1 is a part of Movicom Electric BMS, a modular battery management system, and controls the following devices: 17 - 18 -* //BMS Logic 2.0//; 19 -* //BMS Logic 12//; 20 -* //BMS Logic 18//; 21 -* //BMS Logic RET//. 22 - 23 -= 1.1 Specifications = 24 - 25 25 (% style="width:705px" %) 26 26 |(% style="width:434px" %)**Parameter**|(% style="width:267px" %)**Value** 27 -|(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9 ÷3014 +|(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9 to 30 28 28 |(% style="width:434px" %)Current consumption @12 V, mA (max)|(% style="width:267px" %)100 29 29 |Number of BMS Logic devices|1 to 23 30 30 |Number of cells (maximum)|414 31 31 |(% style="width:434px" %)Number of programmable solid-state relays for contactors (55V, 3A)|(% style="width:267px" %)4 32 32 |(% style="width:434px" %)Number of programmable discrete inputs (dry contact)|(% style="width:267px" %)4 33 -|(% style="width:434px" %)Number of programmable discrete outputs (+5V)|(% style="width:267px" %)4 20 +|(% style="width:434px" %)Number of programmable discrete outputs (+5V, total 200mA)|(% style="width:267px" %)4 34 34 |(% style="width:434px" %)Current sensor type|(% style="width:267px" %)((( 35 35 Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS) 36 36 ))) 37 -|(% style="width:434px" %)Current sensor signal measurement error, V (maximum)|(% style="width:267px" %)0.001 24 +|(% style="width:434px" %)Current sensor signal measurement error, V (maximum)|(% style="width:267px" %)±0.001 38 38 |(% style="width:434px" %)Number of CAN interfaces|(% style="width:267px" %)1 39 39 |(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000 40 40 |(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2 41 41 |(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 42 -|(% style="width:434px" %) **CAN output voltage, V**|(% style="width:267px" %)**5.0 ± 0.5**43 -|(% style="width:434px" %) **CAN output current, mA (maximum)**|(% style="width:267px" %)40044 -|(% style="width:434px" %) **Number of Ethernet interfaces**|(% style="width:267px" %)129 +|(% style="width:434px" %)CAN output voltage, V|(% style="width:267px" %)5.0 ± 0.5 30 +|(% style="width:434px" %)CAN output current, mA (maximum)|(% style="width:267px" %)400 31 +|(% style="width:434px" %)Number of Ethernet interfaces|(% style="width:267px" %)1 45 45 |(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100 46 -|(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32 47 -|(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5 48 -|(% colspan="2" style="width:702px" %)**Operating conditions** 49 -|(% style="width:434px" %)Operating temperature range, °С|(% style="width:267px" %)-40÷75 33 +|(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 17 34 +|(% style="width:434px" %)Weight, g|(% style="width:267px" %)100 ± 10 35 +|(% style="width:434px" %)Operating temperature range, °С|(% style="width:267px" %)-40 to +85 50 50 |(% style="width:434px" %)The degree of protection from external influences|(% style="width:267px" %)IP00 37 +|Headers P1, P6-P9 type |Molex series Mini-Fit 38 +|Headers P11-P15 type |Molex series Micro-Fit 51 51 52 -== 1.2Overall and mounting dimensions ==40 +== Overall and mounting dimensions == 53 53 54 -[[image:1733138859908-160.png]] 42 +[[image:1733138859908-160.png||data-xwiki-image-style-alignment="center" height="403" width="458"]] 55 55 56 -[[image:1733138864828-321.png]] 44 +[[image:1733138864828-321.png||data-xwiki-image-style-alignment="center" height="120" width="463"]] 45 + 46 +
- 1747230329739-415.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +84.7 KB - Content