Last modified by Admin on 2025/05/28 17:04

From version 23.1
edited by Admin
on 2024/12/02 11:28
Change comment: There is no comment for this version
To version 25.1
edited by Admin
on 2024/12/02 11:47
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,25 +1,9 @@
1 1  [[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]]
2 2  
3 -The BMS Main 2.1 is a controller of the modular battery management system that has the following features:
3 +BMS Main 2.1 is a modular BMS controller for 24-1200V batteries. It interacts with measuring modules, calculates the battery state, and protects the battery from damage.
4 4  
5 -* measuring current flowing through the battery;
6 -* communication with BMS Logic that measure voltage and temperature of the battery cells;
7 -* management of charging and discharging the battery;
8 -* management of balancing the battery cells;
9 -* protection of the battery from damage caused by current, voltage, temperature, etc.;
10 -* communication with external equipment (chargers, inverters, indication panels) to provide needed battery operation mode;
11 -* communication with external systems over Ethernet, CAN, RS-485, Wi-Fi;
12 -* collecting and storing battery history data on an SD card.
5 +BMS based on the Main 2.1 can control up to 23 measuring modules and manage a battery consisting of 414 cells.
13 13  
14 -The BMS Main 2.1 is used solely in civil areas. It does not use encryption and cryptography.
15 -
16 -The BMS Main 2.1 is a part of Movicom Electric BMS, a modular battery management system, and controls the following devices:
17 -
18 -* //BMS Logic 2.0//;
19 -* //BMS Logic 12//;
20 -* //BMS Logic 18//;
21 -* //BMS Logic RET//.
22 -
23 23  = 1.1 Specifications =
24 24  
25 25  (% style="width:705px" %)
... ... @@ -39,9 +39,9 @@
39 39  |(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000
40 40  |(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2
41 41  |(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
42 -|(% style="width:434px" %)**CAN output voltage, V**|(% style="width:267px" %)**5.0 ± 0.5**
43 -|(% style="width:434px" %)**CAN output current, mA (maximum)**|(% style="width:267px" %)400
44 -|(% style="width:434px" %)**Number of Ethernet interfaces**|(% style="width:267px" %)1
26 +|(% style="width:434px" %)CAN output voltage, V|(% style="width:267px" %)5.0 ± 0.5
27 +|(% style="width:434px" %)CAN output current, mA (maximum)|(% style="width:267px" %)400
28 +|(% style="width:434px" %)Number of Ethernet interfaces|(% style="width:267px" %)1
45 45  |(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100
46 46  |(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32
47 47  |(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5