Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 2\.1.WebHome1 +Controllers.BMS Main 2\.1.WebHome - Content
-
... ... @@ -1,6 +1,6 @@ 1 -[[image: https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]]1 +[[image:1731519367438-871.1.png]] 2 2 3 -The BMS Main 2.1 is a controller of the modular battery management system that has the following features: 3 +The BMS Main 2.1b is a controller of the modular battery management system that has the following features: 4 4 5 5 * measuring current flowing through the battery; 6 6 * communication with BMS Logic that measure voltage and temperature of the battery cells; ... ... @@ -11,9 +11,9 @@ 11 11 * communication with external systems over Ethernet, CAN, RS-485, Wi-Fi; 12 12 * collecting and storing battery history data on an SD card. 13 13 14 -The BMS Main 2.1 is used solely in civil areas. It does not use encryption and cryptography. 14 +The BMS Main 2.1b is used solely in civil areas. It does not use encryption and cryptography. 15 15 16 -The BMS Main 2.1 is a part of Movicom Electric BMS, a modular battery management system, and controls the following devices: 16 +The BMS Main 2.1b is a part of Movicom Electric BMS, a modular battery management system, and controls the following devices: 17 17 18 18 * //BMS Logic 2.0//; 19 19 * //BMS Logic 12//; ... ... @@ -20,37 +20,38 @@ 20 20 * //BMS Logic 18//; 21 21 * //BMS Logic RET//. 22 22 23 -= 1.1Specifications =23 += Specifications = 24 24 25 -(% style="width:705px" %) 26 -|(% style="width:434px" %)**Parameter**|(% style="width:267px" %)**Value** 27 -|(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9÷30 28 -|(% style="width:434px" %)Current consumption @12 V, mA (max)|(% style="width:267px" %)100 29 -|Number of BMS Logic devices|1 to 23 30 -|Number of cells (maximum)|414 31 -|(% style="width:434px" %)Number of programmable solid-state relays for contactors (55V, 3A)|(% style="width:267px" %)4 32 -|(% style="width:434px" %)Number of programmable discrete inputs (dry contact)|(% style="width:267px" %)4 33 -|(% style="width:434px" %)Number of programmable discrete outputs (+5V)|(% style="width:267px" %)4 34 -|(% style="width:434px" %)Current sensor type|(% style="width:267px" %)((( 35 -Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS) 25 +|**Parameter**|**Value** 26 +|Supply voltage, V|9÷30 27 +|Current consumption @12 V, mA (max)|100 28 +|Number of relays|4 29 +|Number of discrete inputs (dry contact)|4 30 +|Number of discrete outputs (+5V)|4 31 +|Relay 1-2 output voltage, V (max)|55 32 +|Relay 1-2 output current, A (max)|2 33 +|Relay 3-4 output voltage, V (max)|55 34 +|Relay 3-4 output current, A (max)|8 35 +|Current sensor type|((( 36 +Hall-Effect sensor, 37 + 38 +bidirectional, 39 + 40 +supply voltage 5 V 41 + 42 +(LEM series HASS, HTFS) 36 36 ))) 37 -|(% style="width:434px" %)Current sensor signal measurement error, V (maximum)|(% style="width:267px" %)0.001 38 -|(% style="width:434px" %)Number of CAN interfaces|(% style="width:267px" %)1 39 -|(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000 40 -|(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2 41 -|(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 42 -|(% style="width:434px" %)**CAN output voltage, V**|(% style="width:267px" %)**5.0 ± 0.5** 43 -|(% style="width:434px" %)**CAN output current, mA (maximum)**|(% style="width:267px" %)400 44 -|(% style="width:434px" %)**Number of Ethernet interfaces**|(% style="width:267px" %)1 45 -|(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100 46 -|(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32 47 -|(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5 48 -|(% colspan="2" style="width:702px" %)**Operating conditions** 49 -|(% style="width:434px" %)Operating temperature range, °С|(% style="width:267px" %)-40÷75 50 -|(% style="width:434px" %)The degree of protection from external influences|(% style="width:267px" %)IP00 44 +|CAN bus speed, kbps|125, 250 (by default), 500, 1000 45 +|RS-485 baud rate, bps|600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 46 +|Ethernet speed, Mbps|10/100 47 +|RS-485 for communication with BMS Logic baud rate, bps|115200 48 +|Maximum number of the BMS Logic|20 49 +|Dimensions (length × width × height), mm|120 × 120 × 32 50 +|Weight, g|100±5 51 +|(% colspan="2" %)**Operating conditions** 52 +|Operating temperature range, °С|-40÷75 53 +|The degree of protection from external influences|IP00 51 51 52 -== 1.2 Overall and mounting dimensions == 53 53 54 -[[image:1733138859908-160.png]] 55 55 56 - [[image:1733138864828-321.png]]57 +
- 1733138859908-160.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -74.1 KB - Content
- 1733138864828-321.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.5 KB - Content