Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -d rafts.BMS Main 2\.1.WebHome1 +Additional modules.BMS Main 2\.1.WebHome - Content
-
... ... @@ -1,56 +1,25 @@ 1 - [[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1"data-xwiki-image-style-alignment="center"height="266"width="408"]]1 +This document describes configuration procedure of BMS Main 2.x board. Configuring can be done using the web interface available via Ethernet or Wi-Fi. 2 2 3 - TheBMS Main2.1 is acontroller ofthe modular battery managementsystemthathas thefollowing features:3 +Default connection settings for Ethernet are: 4 4 5 -* measuring current flowing through the battery; 6 -* communication with BMS Logic that measure voltage and temperature of the battery cells; 7 -* management of charging and discharging the battery; 8 -* management of balancing the battery cells; 9 -* protection of the battery from damage caused by current, voltage, temperature, etc.; 10 -* communication with external equipment (chargers, inverters, indication panels) to provide needed battery operation mode; 11 -* communication with external systems over Ethernet, CAN, RS-485, Wi-Fi; 12 -* collecting and storing battery history data on an SD card. 5 +* IP address – 192.168.0.100 6 +* Network Mask – 255.255.0.0 7 +* Default gateway – 192.168.0.1 13 13 14 -The BMS Main 2.1 is used solely in civil areas. It does not use encryption and cryptography. 9 +(% class="box infomessage" %) 10 +((( 11 +**Note** 12 +To connect via Ethernet, the computer`s network adapter through which the BMS Main 2.x is configured must be in the same subnet as the target board. 13 +))) 15 15 16 -T heBMS Main2.1is apartofMovicomElectricBMS,amodularbatterymanagementsystem,andcontrolsthefollowingdevices:15 +To connect via Wi-Fi use the IP address which an access point gave to the board (see Wi-Fi for configuring the connection and the “System → Overview” section to find out the IP address). 17 17 18 -* //BMS Logic 2.0//; 19 -* //BMS Logic 12//; 20 -* //BMS Logic 18//; 21 -* //BMS Logic RET//. 17 +Default credentials for changing board settings using the web interface are: 22 22 23 -= 1.1 Specifications = 19 +* Login – user 20 +* Password – bms 24 24 25 -(% style="width:705px" %) 26 -|(% style="width:434px" %)**Parameter**|(% style="width:267px" %)**Value** 27 -|(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9÷30 28 -|(% style="width:434px" %)Current consumption @12 V, mA (max)|(% style="width:267px" %)100 29 -|Number of BMS Logic devices|1 to 23 30 -|Number of cells (maximum)|414 31 -|(% style="width:434px" %)Number of programmable solid-state relays for contactors (55V, 3A)|(% style="width:267px" %)4 32 -|(% style="width:434px" %)Number of programmable discrete inputs (dry contact)|(% style="width:267px" %)4 33 -|(% style="width:434px" %)Number of programmable discrete outputs (+5V)|(% style="width:267px" %)4 34 -|(% style="width:434px" %)Current sensor type|(% style="width:267px" %)((( 35 -Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS) 36 -))) 37 -|(% style="width:434px" %)Current sensor signal measurement error, V (maximum)|(% style="width:267px" %)0.001 38 -|(% style="width:434px" %)Number of CAN interfaces|(% style="width:267px" %)1 39 -|(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000 40 -|(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2 41 -|(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 42 -|(% style="width:434px" %)**CAN output voltage, V**|(% style="width:267px" %)**5.0 ± 0.5** 43 -|(% style="width:434px" %)**CAN output current, mA (maximum)**|(% style="width:267px" %)400 44 -|(% style="width:434px" %)**Number of Ethernet interfaces**|(% style="width:267px" %)1 45 -|(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100 46 -|(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32 47 -|(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5 48 -|(% colspan="2" style="width:702px" %)**Operating conditions** 49 -|(% style="width:434px" %)Operating temperature range, °С|(% style="width:267px" %)-40÷75 50 -|(% style="width:434px" %)The degree of protection from external influences|(% style="width:267px" %)IP00 22 +To access the web interface, enter the IP address of the board (192.168.0.100 by default) in the address bar of the browser. 51 51 52 -== 1.2 Overall and mounting dimensions == 53 53 54 -[[image:1733138859908-160.png]] 55 - 56 -[[image:1733138864828-321.png]] 25 +
- 1731519367438-871.1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -5.4 MB - Content
- 1733138859908-160.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -74.1 KB - Content
- 1733138864828-321.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.5 KB - Content