Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,29 +22,29 @@ 22 22 23 23 = 1.1 Specifications = 24 24 25 -(% style="width: 646px" %)26 -|(% style="width: 386px" %)**Parameter**|(% style="width:258px" %)**Value**27 -|(% style="width: 386px" %)Supply voltage, V|(% style="width:258px" %)9÷3028 -|(% style="width: 386px" %)Current consumption @12 V, mA (max)|(% style="width:258px" %)10029 -|(% style="width: 386px" %)Number of relays|(% style="width:258px" %)430 -|(% style="width: 386px" %)Number of discrete inputs (dry contact)|(% style="width:258px" %)431 -|(% style="width: 386px" %)Number of discrete outputs (+5V)|(% style="width:258px" %)432 -|(% style="width: 386px" %)Relay 1-2 output voltage, V (max)|(% style="width:258px" %)5533 -|(% style="width: 386px" %)Relay 1-2 output current, A (max)|(% style="width:258px" %)234 -|(% style="width: 386px" %)Relay 3-4 output voltage, V (max)|(% style="width:258px" %)5535 -|(% style="width: 386px" %)Relay 3-4 output current, A (max)|(% style="width:258px" %)836 -|(% style="width: 386px" %)Current sensor type|(% style="width:258px" %)(((25 +(% style="width:938px" %) 26 +|(% style="width:412px" %)**Parameter**|(% style="width:523px" %)**Value** 27 +|(% style="width:412px" %)Supply voltage, V|(% style="width:523px" %)9÷30 28 +|(% style="width:412px" %)Current consumption @12 V, mA (max)|(% style="width:523px" %)100 29 +|(% style="width:412px" %)Number of relays|(% style="width:523px" %)4 30 +|(% style="width:412px" %)Number of discrete inputs (dry contact)|(% style="width:523px" %)4 31 +|(% style="width:412px" %)Number of discrete outputs (+5V)|(% style="width:523px" %)4 32 +|(% style="width:412px" %)Relay 1-2 output voltage, V (max)|(% style="width:523px" %)55 33 +|(% style="width:412px" %)Relay 1-2 output current, A (max)|(% style="width:523px" %)2 34 +|(% style="width:412px" %)Relay 3-4 output voltage, V (max)|(% style="width:523px" %)55 35 +|(% style="width:412px" %)Relay 3-4 output current, A (max)|(% style="width:523px" %)8 36 +|(% style="width:412px" %)Current sensor type|(% style="width:523px" %)((( 37 37 Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS) 38 38 ))) 39 -|(% style="width: 386px" %)CAN bus speed, kbps|(% style="width:258px" %)125, 250 (by default), 500, 100040 -|(% style="width: 386px" %)RS-485 baud rate, bps|(% style="width:258px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 11520041 -|(% style="width: 386px" %)Ethernet speed, Mbps|(% style="width:258px" %)10/10042 -|(% style="width: 386px" %)RS-485 for communication with BMS Logic baud rate, bps|(% style="width:258px" %)11520043 -|(% style="width: 386px" %)Maximum number of the BMS Logic|(% style="width:258px" %)2044 -|(% style="width: 386px" %)Dimensions (length × width × height), mm|(% style="width:258px" %)120 × 120 × 3245 -|(% style="width: 386px" %)Weight, g|(% style="width:258px" %)100±546 -|(% colspan="2" style="width: 643px" %)**Operating conditions**47 -|(% style="width: 386px" %)Operating temperature range, °С|(% style="width:258px" %)-40÷7548 -|(% style="width: 386px" %)The degree of protection from external influences|(% style="width:258px" %)IP0039 +|(% style="width:412px" %)CAN bus speed, kbps|(% style="width:523px" %)125, 250 (by default), 500, 1000 40 +|(% style="width:412px" %)RS-485 baud rate, bps|(% style="width:523px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 41 +|(% style="width:412px" %)Ethernet speed, Mbps|(% style="width:523px" %)10/100 42 +|(% style="width:412px" %)RS-485 for communication with BMS Logic baud rate, bps|(% style="width:523px" %)115200 43 +|(% style="width:412px" %)Maximum number of the BMS Logic|(% style="width:523px" %)20 44 +|(% style="width:412px" %)Dimensions (length × width × height), mm|(% style="width:523px" %)120 × 120 × 32 45 +|(% style="width:412px" %)Weight, g|(% style="width:523px" %)100±5 46 +|(% colspan="2" style="width:935px" %)**Operating conditions** 47 +|(% style="width:412px" %)Operating temperature range, °С|(% style="width:523px" %)-40÷75 48 +|(% style="width:412px" %)The degree of protection from external influences|(% style="width:523px" %)IP00 49 49 50 50