... ... @@ -22,29 +22,29 @@
22 22  
23 23  = Specifications =
24 24  
25 -|(% style="width:429px" %)**Parameter**|(% style="width:1092px" %)**Value**
26 -|(% style="width:429px" %)Supply voltage, V|(% style="width:1092px" %)9÷30
27 -|(% style="width:429px" %)Current consumption @12 V, mA (max)|(% style="width:1092px" %)100
28 -|(% style="width:429px" %)Number of relays|(% style="width:1092px" %)4
29 -|(% style="width:429px" %)Number of discrete inputs (dry contact)|(% style="width:1092px" %)4
30 -|(% style="width:429px" %)Number of discrete outputs (+5V)|(% style="width:1092px" %)4
31 -|(% style="width:429px" %)Relay 1-2 output voltage, V (max)|(% style="width:1092px" %)55
32 -|(% style="width:429px" %)Relay 1-2 output current, A (max)|(% style="width:1092px" %)2
33 -|(% style="width:429px" %)Relay 3-4 output voltage, V (max)|(% style="width:1092px" %)55
34 -|(% style="width:429px" %)Relay 3-4 output current, A (max)|(% style="width:1092px" %)8
35 -|(% style="width:429px" %)Current sensor type|(% style="width:1092px" %)(((
25 +(% style="width:938px" %)
26 +|(% style="width:412px" %)**Parameter**|(% style="width:523px" %)**Value**
27 +|(% style="width:412px" %)Supply voltage, V|(% style="width:523px" %)9÷30
28 +|(% style="width:412px" %)Current consumption @12 V, mA (max)|(% style="width:523px" %)100
29 +|(% style="width:412px" %)Number of relays|(% style="width:523px" %)4
30 +|(% style="width:412px" %)Number of discrete inputs (dry contact)|(% style="width:523px" %)4
31 +|(% style="width:412px" %)Number of discrete outputs (+5V)|(% style="width:523px" %)4
32 +|(% style="width:412px" %)Relay 1-2 output voltage, V (max)|(% style="width:523px" %)55
33 +|(% style="width:412px" %)Relay 1-2 output current, A (max)|(% style="width:523px" %)2
34 +|(% style="width:412px" %)Relay 3-4 output voltage, V (max)|(% style="width:523px" %)55
35 +|(% style="width:412px" %)Relay 3-4 output current, A (max)|(% style="width:523px" %)8
36 +|(% style="width:412px" %)Current sensor type|(% style="width:523px" %)(((
36 36  Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS)
37 37  )))
38 -|(% style="width:429px" %)CAN bus speed, kbps|(% style="width:1092px" %)125, 250 (by default), 500, 1000
39 -|(% style="width:429px" %)RS-485 baud rate, bps|(% style="width:1092px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
40 -|(% style="width:429px" %)Ethernet speed, Mbps|(% style="width:1092px" %)10/100
41 -|(% style="width:429px" %)RS-485 for communication with BMS Logic baud rate, bps|(% style="width:1092px" %)115200
42 -|(% style="width:429px" %)Maximum number of the BMS Logic|(% style="width:1092px" %)20
43 -|(% style="width:429px" %)Dimensions (length × width × height), mm|(% style="width:1092px" %)120 × 120 × 32
44 -|(% style="width:429px" %)Weight, g|(% style="width:1092px" %)100±5
45 -|(% colspan="2" %)**Operating conditions**
46 -|(% style="width:429px" %)Operating temperature range, °С|(% style="width:1092px" %)-40÷75
47 -|(% style="width:429px" %)The degree of protection from external influences|(% style="width:1092px" %)IP00
39 +|(% style="width:412px" %)CAN bus speed, kbps|(% style="width:523px" %)125, 250 (by default), 500, 1000
40 +|(% style="width:412px" %)RS-485 baud rate, bps|(% style="width:523px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
41 +|(% style="width:412px" %)Ethernet speed, Mbps|(% style="width:523px" %)10/100
42 +|(% style="width:412px" %)RS-485 for communication with BMS Logic baud rate, bps|(% style="width:523px" %)115200
43 +|(% style="width:412px" %)Maximum number of the BMS Logic|(% style="width:523px" %)20
44 +|(% style="width:412px" %)Dimensions (length × width × height), mm|(% style="width:523px" %)120 × 120 × 32
45 +|(% style="width:412px" %)Weight, g|(% style="width:523px" %)100±5
46 +|(% colspan="2" style="width:935px" %)**Operating conditions**
47 +|(% style="width:412px" %)Operating temperature range, °С|(% style="width:523px" %)-40÷75
48 +|(% style="width:412px" %)The degree of protection from external influences|(% style="width:523px" %)IP00
48 48  
49 -
50 50