Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,29 +22,29 @@ 22 22 23 23 = Specifications = 24 24 25 -|(% style="width:429px" %)**Parameter**|(% style="width:1092px" %)**Value** 26 -|(% style="width:429px" %)Supply voltage, V|(% style="width:1092px" %)9÷30 27 -|(% style="width:429px" %)Current consumption @12 V, mA (max)|(% style="width:1092px" %)100 28 -|(% style="width:429px" %)Number of relays|(% style="width:1092px" %)4 29 -|(% style="width:429px" %)Number of discrete inputs (dry contact)|(% style="width:1092px" %)4 30 -|(% style="width:429px" %)Number of discrete outputs (+5V)|(% style="width:1092px" %)4 31 -|(% style="width:429px" %)Relay 1-2 output voltage, V (max)|(% style="width:1092px" %)55 32 -|(% style="width:429px" %)Relay 1-2 output current, A (max)|(% style="width:1092px" %)2 33 -|(% style="width:429px" %)Relay 3-4 output voltage, V (max)|(% style="width:1092px" %)55 34 -|(% style="width:429px" %)Relay 3-4 output current, A (max)|(% style="width:1092px" %)8 35 -|(% style="width:429px" %)Current sensor type|(% style="width:1092px" %)((( 25 +(% style="width:938px" %) 26 +|(% style="width:412px" %)**Parameter**|(% style="width:523px" %)**Value** 27 +|(% style="width:412px" %)Supply voltage, V|(% style="width:523px" %)9÷30 28 +|(% style="width:412px" %)Current consumption @12 V, mA (max)|(% style="width:523px" %)100 29 +|(% style="width:412px" %)Number of relays|(% style="width:523px" %)4 30 +|(% style="width:412px" %)Number of discrete inputs (dry contact)|(% style="width:523px" %)4 31 +|(% style="width:412px" %)Number of discrete outputs (+5V)|(% style="width:523px" %)4 32 +|(% style="width:412px" %)Relay 1-2 output voltage, V (max)|(% style="width:523px" %)55 33 +|(% style="width:412px" %)Relay 1-2 output current, A (max)|(% style="width:523px" %)2 34 +|(% style="width:412px" %)Relay 3-4 output voltage, V (max)|(% style="width:523px" %)55 35 +|(% style="width:412px" %)Relay 3-4 output current, A (max)|(% style="width:523px" %)8 36 +|(% style="width:412px" %)Current sensor type|(% style="width:523px" %)((( 36 36 Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS) 37 37 ))) 38 -|(% style="width:42 9px" %)CAN bus speed, kbps|(% style="width:1092px" %)125, 250 (by default), 500, 100039 -|(% style="width:42 9px" %)RS-485 baud rate, bps|(% style="width:1092px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 11520040 -|(% style="width:42 9px" %)Ethernet speed, Mbps|(% style="width:1092px" %)10/10041 -|(% style="width:42 9px" %)RS-485 for communication with BMS Logic baud rate, bps|(% style="width:1092px" %)11520042 -|(% style="width:42 9px" %)Maximum number of the BMS Logic|(% style="width:1092px" %)2043 -|(% style="width:42 9px" %)Dimensions (length × width × height), mm|(% style="width:1092px" %)120 × 120 × 3244 -|(% style="width:42 9px" %)Weight, g|(% style="width:1092px" %)100±545 -|(% colspan="2" %)**Operating conditions** 46 -|(% style="width:42 9px" %)Operating temperature range, °С|(% style="width:1092px" %)-40÷7547 -|(% style="width:42 9px" %)The degree of protection from external influences|(% style="width:1092px" %)IP0039 +|(% style="width:412px" %)CAN bus speed, kbps|(% style="width:523px" %)125, 250 (by default), 500, 1000 40 +|(% style="width:412px" %)RS-485 baud rate, bps|(% style="width:523px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 41 +|(% style="width:412px" %)Ethernet speed, Mbps|(% style="width:523px" %)10/100 42 +|(% style="width:412px" %)RS-485 for communication with BMS Logic baud rate, bps|(% style="width:523px" %)115200 43 +|(% style="width:412px" %)Maximum number of the BMS Logic|(% style="width:523px" %)20 44 +|(% style="width:412px" %)Dimensions (length × width × height), mm|(% style="width:523px" %)120 × 120 × 32 45 +|(% style="width:412px" %)Weight, g|(% style="width:523px" %)100±5 46 +|(% colspan="2" style="width:935px" %)**Operating conditions** 47 +|(% style="width:412px" %)Operating temperature range, °С|(% style="width:523px" %)-40÷75 48 +|(% style="width:412px" %)The degree of protection from external influences|(% style="width:523px" %)IP00 48 48 49 - 50 50