1 -[[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" height="266" width="408"]]
1 +This document describes configuration procedure of BMS Main 2.x board. Configuring can be done using the web interface available via Ethernet or Wi-Fi.
2 2  
3 -The BMS Main 2.1b is a controller of the modular battery management system that has the following features:
3 +Default connection settings for Ethernet are:
4 4  
5 -* measuring current flowing through the battery;
6 -* communication with BMS Logic that measure voltage and temperature of the battery cells;
7 -* management of charging and discharging the battery;
8 -* management of balancing the battery cells;
9 -* protection of the battery from damage caused by current, voltage, temperature, etc.;
10 -* communication with external equipment (chargers, inverters, indication panels) to provide needed battery operation mode;
11 -* communication with external systems over Ethernet, CAN, RS-485, Wi-Fi;
12 -* collecting and storing battery history data on an SD card.
5 +* IP address – 192.168.0.100
6 +* Network Mask – 255.255.0.0
7 +* Default gateway – 192.168.0.1
13 13  
14 -The BMS Main 2.1b is used solely in civil areas. It does not use encryption and cryptography.
9 +(% class="box infomessage" %)
10 +(((
11 +**Note**
12 +To connect via Ethernet, the computer`s network adapter through which the BMS Main 2.x is configured must be in the same subnet as the target board.
13 +)))
15 15  
16 -The BMS Main 2.1b is a part of Movicom Electric BMS, a modular battery management system, and controls the following devices:
15 +To connect via Wi-Fi use the IP address which an access point gave to the board (see Wi-Fi for configuring the connection and the “System Overview” section to find out the IP address).
17 17  
18 -* //BMS Logic 2.0//;
19 -* //BMS Logic 12//;
20 -* //BMS Logic 18//;
21 -* //BMS Logic RET//.
17 +Default credentials for changing board settings using the web interface are:
22 22  
23 -= Specifications =
19 +* Login – user
20 +* Password – bms
24 24  
25 -|**Parameter**|**Value**
26 -|Supply voltage, V|9÷30
27 -|Current consumption @12 V, mA (max)|100
28 -|Number of relays|4
29 -|Number of discrete inputs (dry contact)|4
30 -|Number of discrete outputs (+5V)|4
31 -|Relay 1-2 output voltage, V (max)|55
32 -|Relay 1-2 output current, A (max)|2
33 -|Relay 3-4 output voltage, V (max)|55
34 -|Relay 3-4 output current, A (max)|8
35 -|Current sensor type|(((
36 -Hall-Effect sensor,
22 +To access the web interface, enter the IP address of the board (192.168.0.100 by default) in the address bar of the browser.
37 37  
38 -bidirectional,
39 39  
40 -supply voltage 5 V
41 -
42 -(LEM series HASS, HTFS)
43 -)))
44 -|CAN bus speed, kbps|125, 250 (by default), 500, 1000
45 -|RS-485 baud rate, bps|600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
46 -|Ethernet speed, Mbps|10/100
47 -|RS-485 for communication with BMS Logic baud rate, bps|115200
48 -|Maximum number of the BMS Logic|20
49 -|Dimensions (length × width × height), mm|120 × 120 × 32
50 -|Weight, g|100±5
51 -|(% colspan="2" %)**Operating conditions**
52 -|Operating temperature range, °С|-40÷75
53 -|The degree of protection from external influences|IP00
54 -
55 -
56 -
57 57  
1731519367438-871.1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -5.4 MB