Last modified by Admin on 2025/05/28 17:04

From version 13.1
edited by Admin
on 2024/11/13 16:42
Change comment: Deleted image "1731515055585-924.png"
To version 31.1
edited by Admin
on 2024/12/11 09:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -1. General information
1 +1. Technical specifications
Parent
... ... @@ -1,1 +1,1 @@
1 -Additional modules.BMS Main 2\.1.WebHome
1 +drafts.BMS Main 2\.1.WebHome
Content
... ... @@ -1,25 +1,45 @@
1 -This document describes configuration procedure of BMS Main 2.x board. Configuring can be done using the web interface available via Ethernet or Wi-Fi.
1 +(% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 += Technical specifications =
2 2  
3 -Default connection settings for Ethernet are:
4 +[[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]]
4 4  
5 -* IP address – 192.168.0.100
6 -* Network Mask – 255.255.0.0
7 -* Default gateway – 192.168.0.1
6 +BMS Main 2.1 is a modular BMS controller for 24-1200V batteries. It interacts with measuring modules, calculates the battery state, and protects the battery from damage.
8 8  
9 -(% class="box infomessage" %)
10 -(((
11 -**Note**
12 -To connect via Ethernet, the computer`s network adapter through which the BMS Main 2.x is configured must be in the same subnet as the target board.
13 -)))
8 +BMS based on the Main 2.1 can control up to 23 measuring modules and manage a battery consisting of 414 cells.
14 14  
15 -To connect via Wi-Fi use the IP address which an access point gave to the board (see Wi-Fi for configuring the connection and the “System → Overview” section to find out the IP address).
10 +== 1.1 Specifications ==
16 16  
17 -Default credentials for changing board settings using the web interface are:
12 +(% style="width:705px" %)
13 +|(% style="width:434px" %)**Parameter**|(% style="width:267px" %)**Value**
14 +|(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9÷30
15 +|(% style="width:434px" %)Current consumption @12 V, mA (max)|(% style="width:267px" %)100
16 +|Number of BMS Logic devices|1 to 23
17 +|Number of cells (maximum)|414
18 +|(% style="width:434px" %)Number of programmable solid-state relays for contactors (55V, 3A)|(% style="width:267px" %)4
19 +|(% style="width:434px" %)Number of programmable discrete inputs (dry contact)|(% style="width:267px" %)4
20 +|(% style="width:434px" %)Number of programmable discrete outputs (+5V)|(% style="width:267px" %)4
21 +|(% style="width:434px" %)Current sensor type|(% style="width:267px" %)(((
22 +Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS)
23 +)))
24 +|(% style="width:434px" %)Current sensor signal measurement error, V (maximum)|(% style="width:267px" %)0.001
25 +|(% style="width:434px" %)Number of CAN interfaces|(% style="width:267px" %)1
26 +|(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000
27 +|(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2
28 +|(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
29 +|(% style="width:434px" %)CAN output voltage, V|(% style="width:267px" %)5.0 ± 0.5
30 +|(% style="width:434px" %)CAN output current, mA (maximum)|(% style="width:267px" %)400
31 +|(% style="width:434px" %)Number of Ethernet interfaces|(% style="width:267px" %)1
32 +|(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100
33 +|(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32
34 +|(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5
35 +|(% colspan="2" style="width:702px" %)**Operating conditions**
36 +|(% style="width:434px" %)Operating temperature range, °С|(% style="width:267px" %)-40÷75
37 +|(% style="width:434px" %)The degree of protection from external influences|(% style="width:267px" %)IP00
18 18  
19 -* Login – user
20 -* Password – bms
39 +== 1.2 Overall and mounting dimensions ==
21 21  
22 -To access the web interface, enter the IP address of the board (192.168.0.100 by default) in the address bar of the browser.
41 +[[image:1733138859908-160.png||data-xwiki-image-style-alignment="center" height="403" width="458"]]
23 23  
43 +[[image:1733138864828-321.png||data-xwiki-image-style-alignment="center" height="120" width="463"]]
24 24  
25 25  
1731519367438-871.1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +5.4 MB
Content
1733138859908-160.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +74.1 KB
Content
1733138864828-321.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +19.5 KB
Content