Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 17:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Additional modules.BMS Main 2\.1.WebHome1 +drafts.BMS Main 2\.1.WebHome - Content
-
... ... @@ -1,25 +1,40 @@ 1 - Thisdocument describesconfigurationrocedure ofBMS Main 2.xboard. Configuring can bedone usingheweb interfaceavailablevia Ethernetor Wi-Fi.1 +[[image:https://movicomelectric.com/wa-data/public/site/img/08-BMS-Main-2-1.png||alt="BMS Main 2.1" data-xwiki-image-style-alignment="center" height="266" width="408"]] 2 2 3 - DefaultconnectionsettingsforEthernet are:3 +BMS Main 2.1 is a modular BMS controller for 24-1200V batteries. It interacts with measuring modules, calculates the battery state, and protects the battery from damage. 4 4 5 -* IP address – 192.168.0.100 6 -* Network Mask – 255.255.0.0 7 -* Default gateway – 192.168.0.1 5 +BMS based on the Main 2.1 can control up to 23 measuring modules and manage a battery consisting of 414 cells. 8 8 9 -(% class="box infomessage" %) 10 -((( 11 -**Note** 12 -To connect via Ethernet, the computer`s network adapter through which the BMS Main 2.x is configured must be in the same subnet as the target board. 7 += 1.1 Specifications = 8 + 9 +(% style="width:705px" %) 10 +|(% style="width:434px" %)**Parameter**|(% style="width:267px" %)**Value** 11 +|(% style="width:434px" %)Supply voltage, V|(% style="width:267px" %)9÷30 12 +|(% style="width:434px" %)Current consumption @12 V, mA (max)|(% style="width:267px" %)100 13 +|Number of BMS Logic devices|1 to 23 14 +|Number of cells (maximum)|414 15 +|(% style="width:434px" %)Number of programmable solid-state relays for contactors (55V, 3A)|(% style="width:267px" %)4 16 +|(% style="width:434px" %)Number of programmable discrete inputs (dry contact)|(% style="width:267px" %)4 17 +|(% style="width:434px" %)Number of programmable discrete outputs (+5V)|(% style="width:267px" %)4 18 +|(% style="width:434px" %)Current sensor type|(% style="width:267px" %)((( 19 +Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS) 13 13 ))) 21 +|(% style="width:434px" %)Current sensor signal measurement error, V (maximum)|(% style="width:267px" %)0.001 22 +|(% style="width:434px" %)Number of CAN interfaces|(% style="width:267px" %)1 23 +|(% style="width:434px" %)CAN bus speed, kbps|(% style="width:267px" %)125, 250 (by default), 500, 1000 24 +|(% style="width:434px" %)Number of RS-485 interfaces|(% style="width:267px" %)2 25 +|(% style="width:434px" %)RS-485 baud rate, bps|(% style="width:267px" %)600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200 26 +|(% style="width:434px" %)**CAN output voltage, V**|(% style="width:267px" %)**5.0 ± 0.5** 27 +|(% style="width:434px" %)**CAN output current, mA (maximum)**|(% style="width:267px" %)400 28 +|(% style="width:434px" %)**Number of Ethernet interfaces**|(% style="width:267px" %)1 29 +|(% style="width:434px" %)Ethernet speed, Mbps|(% style="width:267px" %)10/100 30 +|(% style="width:434px" %)Dimensions (length × width × height), mm|(% style="width:267px" %)120 × 120 × 32 31 +|(% style="width:434px" %)Weight, g|(% style="width:267px" %)100±5 32 +|(% colspan="2" style="width:702px" %)**Operating conditions** 33 +|(% style="width:434px" %)Operating temperature range, °С|(% style="width:267px" %)-40÷75 34 +|(% style="width:434px" %)The degree of protection from external influences|(% style="width:267px" %)IP00 14 14 15 - Toconnectvia Wi-Fi usethe IP address whichanaccess point gave to the board(see Wi-Fi for configuringthe connectionandthe “System→ Overview”sectionto find out the IP address).36 +== 1.2 Overall and mounting dimensions == 16 16 17 - Default credentials for changing board settings using the web interface are:38 +[[image:1733138859908-160.png]] 18 18 19 -* Login – user 20 -* Password – bms 21 - 22 -To access the web interface, enter the IP address of the board (192.168.0.100 by default) in the address bar of the browser. 23 - 24 - 25 - 40 +[[image:1733138864828-321.png]]
- 1731519367438-871.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +5.4 MB - Content
- 1733138859908-160.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +74.1 KB - Content
- 1733138864828-321.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.5 KB - Content