3. Configuration
Last modified by Admin on 2024/12/11 11:18
Configuration
Setting device address
The address is set by the SWD1 switch. Address 0 (all switches are raised) is incorrect.
The address from 1 to 20 is set on the switches as a binary number. The ON state (bottom position) corresponds to a single digit value. The switch with the number 1 corresponds to the lower order. The address is read by the device at initialization, so to change the address it is necessary to switch off and turn on the device.
To select the proper device address, use the following table:
Address | SWD1 | |||||
1 | 2 | 3 | 4 | 5 | 6 | |
1 | ON | OFF | OFF | OFF | OFF | OFF |
2 | OFF | ON | OFF | OFF | OFF | OFF |
3 | ON | ON | OFF | OFF | OFF | OFF |
4 | OFF | OFF | ON | OFF | OFF | OFF |
5 | ON | OFF | ON | OFF | OFF | OFF |
6 | OFF | ON | ON | OFF | OFF | OFF |
7 | ON | ON | ON | OFF | OFF | OFF |
8 | OFF | OFF | OFF | ON | OFF | OFF |
9 | ON | OFF | OFF | ON | OFF | OFF |
10 | OFF | ON | OFF | ON | OFF | OFF |
11 | ON | ON | OFF | ON | OFF | OFF |
12 | OFF | OFF | ON | ON | OFF | OFF |
13 | ON | OFF | ON | ON | OFF | OFF |
14 | OFF | ON | ON | ON | OFF | OFF |
15 | ON | ON | ON | ON | OFF | OFF |
16 | OFF | OFF | OFF | OFF | ON | OFF |
17 | ON | OFF | OFF | OFF | ON | OFF |
18 | OFF | ON | OFF | OFF | ON | OFF |
19 | ON | ON | OFF | OFF | ON | OFF |
20 | OFF | OFF | ON | OFF | ON | OFF |
Address selection requirements:
- it is necessary to use consecutive addresses, without omissions;
- it is necessary to use addresses from 1 to 20;
- when choosing an address, follow the rule: a device with a smaller address serves less potential;
- to facilitate subsequent maintenance, it is recommended to create a schematic indicating the location of the BMS Logic 2.0 and their addresses.