Wiki source code of 3. Configuration
Last modified by Admin on 2025/01/09 15:17
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) | ||
2 | = Configuration = | ||
3 | |||
4 | == Connecting device to PC == | ||
5 | |||
6 | To connect the BMS Logic 18 to a PC, use the BMS USB-RS485 adapter. It allows to power and communicate with the BMS Logic 18: | ||
7 | |||
8 | 1. Connect the BMS USB-RS485 to the BMS Logic 18: | ||
9 | a) the communication circuits (X3 -> X4); | ||
10 | b) the circuits of cells (X5 -> X1). | ||
11 | 1. Connect the BMS USB-RS485 to a PC using a mini-USB or USB-C cable. | ||
12 | 1. Turn all the BMS USB-RS485’s switches to the “I” position. | ||
13 | |||
14 | === Communication and power cable === | ||
15 | |||
16 | [[image:1733151480872-233.png||data-xwiki-image-style-alignment="center" height="239" width="435"]] | ||
17 | |||
18 | The wires of the communication and power cable must be connected according to the following table: | ||
19 | |||
20 | (% style="width:393px" %) | ||
21 | |**Circuit name**|(% style="width:148px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:149px" %)**Pin of the connector to BMS Logic 18** | ||
22 | |**RS485_A**|(% style="width:148px" %)1|(% style="width:149px" %)1 | ||
23 | |**RS485_B**|(% style="width:148px" %)2|(% style="width:149px" %)2 | ||
24 | |**+5V**|(% style="width:148px" %)3|(% style="width:149px" %)3 | ||
25 | |**GND**|(% style="width:148px" %)4|(% style="width:149px" %)4 | ||
26 | |||
27 | === Cells cable === | ||
28 | |||
29 | [[image:1733151480875-350.png||data-xwiki-image-style-alignment="center" height="137" width="713"]] | ||
30 | |||
31 | [[image:1733151480876-978.png||data-xwiki-image-style-alignment="center" height="224" width="441"]] | ||
32 | |||
33 | The wires of the cells cable must be connected according to the following table: | ||
34 | |||
35 | (% style="width:401.818px" %) | ||
36 | |**Circuit name**|(% style="width:151px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:152px" %)**Pin of the connector to BMS Logic 18** | ||
37 | |**V-**|(% style="width:151px" %)1|(% style="width:152px" %)1 | ||
38 | |**C1**|(% style="width:151px" %)13|(% style="width:152px" %)12 | ||
39 | |**C2**|(% style="width:151px" %)2|(% style="width:152px" %)2 | ||
40 | |**C3**|(% style="width:151px" %)14|(% style="width:152px" %)13 | ||
41 | |**C4**|(% style="width:151px" %)3|(% style="width:152px" %)3 | ||
42 | |**C5**|(% style="width:151px" %)15|(% style="width:152px" %)14 | ||
43 | |**C6**|(% style="width:151px" %)4|(% style="width:152px" %)4 | ||
44 | |**C7**|(% style="width:151px" %)16|(% style="width:152px" %)15 | ||
45 | |**C8**|(% style="width:151px" %)5|(% style="width:152px" %)5 | ||
46 | |**C9**|(% style="width:151px" %)17|(% style="width:152px" %)16 | ||
47 | |**C10**|(% style="width:151px" %)6|(% style="width:152px" %)6 | ||
48 | |**C11**|(% style="width:151px" %)18|(% style="width:152px" %)17 | ||
49 | |**C12**|(% style="width:151px" %)7|(% style="width:152px" %)7 | ||
50 | |**C13**|(% style="width:151px" %)19|(% style="width:152px" %)18 | ||
51 | |**C14**|(% style="width:151px" %)8|(% style="width:152px" %)8 | ||
52 | |**C15**|(% style="width:151px" %)20|(% style="width:152px" %)19 | ||
53 | |**C16**|(% style="width:151px" %)9|(% style="width:152px" %)9 | ||
54 | |**C17**|(% style="width:151px" %)21|(% style="width:152px" %)20 | ||
55 | |**C18**|(% style="width:151px" %)10|(% style="width:152px" %)10 | ||
56 | |||
57 | == Setting device address == | ||
58 | |||
59 | Launch the ElectricDeviceMonitor, then select the “BMS Logic 12/18 3.x” monitor: | ||
60 | |||
61 | [[image:1733151480877-266.png||data-xwiki-image-style-alignment="center" height="351" width="321"]] | ||
62 | |||
63 | Select the following settings to connect to the BMS Logic 18: | ||
64 | |||
65 | * 115200 bps, | ||
66 | * 8 bits, | ||
67 | * no parity, | ||
68 | * 1 stop bit, | ||
69 | * device address 247. | ||
70 | |||
71 | The address 247 is a service address that the device will always answer. | ||
72 | |||
73 | [[image:1733151480878-434.png||data-xwiki-image-style-alignment="center" height="263" width="477"]] | ||
74 | |||
75 | Check the connection with the BMS Logic 18 is established. | ||
76 | |||
77 | Set the needed device address and click the “Save” button: | ||
78 | |||
79 | [[image:1733151480878-552.png||data-xwiki-image-style-alignment="center" height="461" width="707"]] | ||
80 | |||
81 |