Wiki source code of 3. Configuration

Last modified by Admin on 2025/01/09 15:17

Show last authors
1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Configuration =
3
4 == ​​​​​​ Connecting device to PC ==
5
6 To connect the BMS Logic 18 to a PC, use the BMS USB-RS485 adapter. It allows to power and communicate with the BMS Logic 18:
7
8 1. Connect the BMS USB-RS485 to the BMS Logic 18:
9 a) the communication circuits (X3 -> X4);
10 b) the circuits of cells (X5 -> X1).
11 1. Connect the BMS USB-RS485 to a PC using a mini-USB or USB-C cable.
12 1. Turn all the BMS USB-RS485’s switches to the “I” position.
13
14 === Communication and power cable ===
15
16 [[image:1733151480872-233.png||data-xwiki-image-style-alignment="center" height="239" width="435"]]
17
18 The wires of the communication and power cable must be connected according to the following table:
19
20 (% style="width:393px" %)
21 |**Circuit name**|(% style="width:148px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:149px" %)**Pin of the connector to BMS Logic 18**
22 |**RS485_A**|(% style="width:148px" %)1|(% style="width:149px" %)1
23 |**RS485_B**|(% style="width:148px" %)2|(% style="width:149px" %)2
24 |**+5V**|(% style="width:148px" %)3|(% style="width:149px" %)3
25 |**GND**|(% style="width:148px" %)4|(% style="width:149px" %)4
26
27 === Cells cable ===
28
29 [[image:1733151480875-350.png||data-xwiki-image-style-alignment="center" height="137" width="713"]]
30
31 [[image:1733151480876-978.png||data-xwiki-image-style-alignment="center" height="224" width="441"]]
32
33 The wires of the cells cable must be connected according to the following table:
34
35 (% style="width:401.818px" %)
36 |**Circuit name**|(% style="width:151px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:152px" %)**Pin of the connector to BMS Logic 18**
37 |**V-**|(% style="width:151px" %)1|(% style="width:152px" %)1
38 |**C1**|(% style="width:151px" %)13|(% style="width:152px" %)12
39 |**C2**|(% style="width:151px" %)2|(% style="width:152px" %)2
40 |**C3**|(% style="width:151px" %)14|(% style="width:152px" %)13
41 |**C4**|(% style="width:151px" %)3|(% style="width:152px" %)3
42 |**C5**|(% style="width:151px" %)15|(% style="width:152px" %)14
43 |**C6**|(% style="width:151px" %)4|(% style="width:152px" %)4
44 |**C7**|(% style="width:151px" %)16|(% style="width:152px" %)15
45 |**C8**|(% style="width:151px" %)5|(% style="width:152px" %)5
46 |**C9**|(% style="width:151px" %)17|(% style="width:152px" %)16
47 |**C10**|(% style="width:151px" %)6|(% style="width:152px" %)6
48 |**C11**|(% style="width:151px" %)18|(% style="width:152px" %)17
49 |**C12**|(% style="width:151px" %)7|(% style="width:152px" %)7
50 |**C13**|(% style="width:151px" %)19|(% style="width:152px" %)18
51 |**C14**|(% style="width:151px" %)8|(% style="width:152px" %)8
52 |**C15**|(% style="width:151px" %)20|(% style="width:152px" %)19
53 |**C16**|(% style="width:151px" %)9|(% style="width:152px" %)9
54 |**C17**|(% style="width:151px" %)21|(% style="width:152px" %)20
55 |**C18**|(% style="width:151px" %)10|(% style="width:152px" %)10
56
57 == Setting device address ==
58
59 Launch the ElectricDeviceMonitor, then select the “BMS Logic 12/18 3.x” monitor:
60
61 [[image:1733151480877-266.png||data-xwiki-image-style-alignment="center" height="351" width="321"]]
62
63 Select the following settings to connect to the BMS Logic 18:
64
65 * 115200 bps,
66 * 8 bits,
67 * no parity,
68 * 1 stop bit,
69 * device address 247.
70
71 The address 247 is a service address that the device will always answer.
72
73 [[image:1733151480878-434.png||data-xwiki-image-style-alignment="center" height="263" width="477"]]
74
75 Check the connection with the BMS Logic 18 is established.
76
77 Set the needed device address and click the “Save” button:
78