Changes for page 3. Configuration

Last modified by Admin on 2025/01/09 15:17

From version 6.1
edited by Admin
on 2025/01/09 15:16
Change comment: There is no comment for this version
To version 1.1
edited by Admin
on 2024/12/02 15:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS Logic 18.WebHome
1 +drafts.BMS Logic 18.WebHome
Content
... ... @@ -1,8 +1,5 @@
1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= Configuration =
1 +== 3.1​​​​​​ Connecting device to PC ==
3 3  
4 -== ​​​​​​ Connecting device to PC ==
5 -
6 6  To connect the BMS Logic 18 to a PC, use the BMS USB-RS485 adapter. It allows to power and communicate with the BMS Logic 18:
7 7  
8 8  1. Connect the BMS USB-RS485 to the BMS Logic 18:
... ... @@ -11,22 +11,21 @@
11 11  1. Connect the BMS USB-RS485 to a PC using a mini-USB or USB-C cable.
12 12  1. Turn all the BMS USB-RS485’s switches to the “I” position.
13 13  
14 -=== Communication and power cable ===
11 +=== 3.1.1 Communication and power cable ===
15 15  
16 -[[image:1733151480872-233.png||data-xwiki-image-style-alignment="center" height="239" width="435"]]
13 +[[image:1733151480872-233.png||data-xwiki-image-style-alignment="center" height="255" width="465"]]
17 17  
18 18  The wires of the communication and power cable must be connected according to the following table:
19 19  
20 -(% style="width:393px" %)
21 -|**Circuit name**|(% style="width:148px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:149px" %)**Pin of the connector to BMS Logic 18**
22 -|**RS485_A**|(% style="width:148px" %)1|(% style="width:149px" %)1
23 -|**RS485_B**|(% style="width:148px" %)2|(% style="width:149px" %)2
24 -|**+5V**|(% style="width:148px" %)3|(% style="width:149px" %)3
25 -|**GND**|(% style="width:148px" %)4|(% style="width:149px" %)4
17 +|**Circuit name**|(% style="width:148px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:386px" %)**Pin of the connector to BMS Logic 18**
18 +|**RS485_A**|(% style="width:148px" %)1|(% style="width:386px" %)1
19 +|**RS485_B**|(% style="width:148px" %)2|(% style="width:386px" %)2
20 +|**+5V**|(% style="width:148px" %)3|(% style="width:386px" %)3
21 +|**GND**|(% style="width:148px" %)4|(% style="width:386px" %)4
26 26  
27 -=== Cells cable ===
23 +=== 3.1.2 Cells cable ===
28 28  
29 -[[image:1733151480875-350.png||data-xwiki-image-style-alignment="center" height="137" width="713"]]
25 +[[image:1733151480875-350.png||data-xwiki-image-style-alignment="center" height="126" width="656"]]
30 30  
31 31  [[image:1733151480876-978.png||data-xwiki-image-style-alignment="center" height="224" width="441"]]
32 32  
... ... @@ -54,27 +54,20 @@
54 54  |**C17**|(% style="width:151px" %)21|(% style="width:152px" %)20
55 55  |**C18**|(% style="width:151px" %)10|(% style="width:152px" %)10
56 56  
57 -== Setting device address ==
53 +3.2 Setting device address
58 58  
59 59  Launch the ElectricDeviceMonitor, then select the “BMS Logic 12/18 3.x” monitor:
60 60  
61 -[[image:1733151480877-266.png||data-xwiki-image-style-alignment="center" height="351" width="321"]]
57 +[[image:1733151480877-266.png||data-xwiki-image-style-alignment="center" height="267" width="244"]]
62 62  
63 -Select the following settings to connect to the BMS Logic 18:
59 +Select the following settings to connect to the BMS Logic 18: 115200 bps, 8 bits, no parity, 1 stop bit, device address 247. The address 247 is a service address that the device will always answer.
64 64  
65 -* 115200 bps, 8 bits,
66 -* no parity,
67 -* 1 stop bit,
68 -* device address 247.
61 +[[image:1733151480878-434.png||data-xwiki-image-style-alignment="center" height="248" width="450"]]
69 69  
70 -The address 247 is a service address that the device will always answer.
71 -
72 -[[image:1733151480878-434.png||data-xwiki-image-style-alignment="center" height="263" width="477"]]
73 -
74 74  Check the connection with the BMS Logic 18 is established.
75 75  
76 76  Set the needed device address and click the “Save” button:
77 77  
78 -[[image:1733151480878-552.png||data-xwiki-image-style-alignment="center" height="461" width="707"]]
67 +[[image:1733151480878-552.png||data-xwiki-image-style-alignment="center" height="432" width="663"]]
79 79  
80 80