Changes for page 3. Configuration

Last modified by Admin on 2025/01/09 15:17

From version 1.1
edited by Admin
on 2024/12/02 15:02
Change comment: There is no comment for this version
To version 4.1
edited by Admin
on 2024/12/02 16:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -10,19 +10,20 @@
10 10  
11 11  === 3.1.1 Communication and power cable ===
12 12  
13 -[[image:1733151480872-233.png||data-xwiki-image-style-alignment="center" height="255" width="465"]]
13 +[[image:1733151480872-233.png||data-xwiki-image-style-alignment="center" height="239" width="435"]]
14 14  
15 15  The wires of the communication and power cable must be connected according to the following table:
16 16  
17 -|**Circuit name**|(% style="width:148px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:386px" %)**Pin of the connector to BMS Logic 18**
18 -|**RS485_A**|(% style="width:148px" %)1|(% style="width:386px" %)1
19 -|**RS485_B**|(% style="width:148px" %)2|(% style="width:386px" %)2
20 -|**+5V**|(% style="width:148px" %)3|(% style="width:386px" %)3
21 -|**GND**|(% style="width:148px" %)4|(% style="width:386px" %)4
17 +(% style="width:393px" %)
18 +|**Circuit name**|(% style="width:148px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:149px" %)**Pin of the connector to BMS Logic 18**
19 +|**RS485_A**|(% style="width:148px" %)1|(% style="width:149px" %)1
20 +|**RS485_B**|(% style="width:148px" %)2|(% style="width:149px" %)2
21 +|**+5V**|(% style="width:148px" %)3|(% style="width:149px" %)3
22 +|**GND**|(% style="width:148px" %)4|(% style="width:149px" %)4
22 22  
23 23  === 3.1.2 Cells cable ===
24 24  
25 -[[image:1733151480875-350.png||data-xwiki-image-style-alignment="center" height="126" width="656"]]
26 +[[image:1733151480875-350.png||data-xwiki-image-style-alignment="center" height="137" width="713"]]
26 26  
27 27  [[image:1733151480876-978.png||data-xwiki-image-style-alignment="center" height="224" width="441"]]
28 28  
... ... @@ -50,20 +50,20 @@
50 50  |**C17**|(% style="width:151px" %)21|(% style="width:152px" %)20
51 51  |**C18**|(% style="width:151px" %)10|(% style="width:152px" %)10
52 52  
53 -3.2 Setting device address
54 +== 3.2 Setting device address ==
54 54  
55 55  Launch the ElectricDeviceMonitor, then select the “BMS Logic 12/18 3.x” monitor:
56 56  
57 -[[image:1733151480877-266.png||data-xwiki-image-style-alignment="center" height="267" width="244"]]
58 +[[image:1733151480877-266.png||data-xwiki-image-style-alignment="center" height="351" width="321"]]
58 58  
59 59  Select the following settings to connect to the BMS Logic 18: 115200 bps, 8 bits, no parity, 1 stop bit, device address 247. The address 247 is a service address that the device will always answer.
60 60  
61 -[[image:1733151480878-434.png||data-xwiki-image-style-alignment="center" height="248" width="450"]]
62 +[[image:1733151480878-434.png||data-xwiki-image-style-alignment="center" height="263" width="477"]]
62 62  
63 63  Check the connection with the BMS Logic 18 is established.
64 64  
65 65  Set the needed device address and click the “Save” button:
66 66  
67 -[[image:1733151480878-552.png||data-xwiki-image-style-alignment="center" height="432" width="663"]]
68 +[[image:1733151480878-552.png||data-xwiki-image-style-alignment="center" height="461" width="707"]]
68 68  
69 69