Changes for page 3. Configuration
Last modified by Admin on 2025/01/09 15:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,19 +10,20 @@ 10 10 11 11 === 3.1.1 Communication and power cable === 12 12 13 -[[image:1733151480872-233.png||data-xwiki-image-style-alignment="center" height="2 55" width="465"]]13 +[[image:1733151480872-233.png||data-xwiki-image-style-alignment="center" height="239" width="435"]] 14 14 15 15 The wires of the communication and power cable must be connected according to the following table: 16 16 17 -|**Circuit name**|(% style="width:148px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:386px" %)**Pin of the connector to BMS Logic 18** 18 -|**RS485_A**|(% style="width:148px" %)1|(% style="width:386px" %)1 19 -|**RS485_B**|(% style="width:148px" %)2|(% style="width:386px" %)2 20 -|**+5V**|(% style="width:148px" %)3|(% style="width:386px" %)3 21 -|**GND**|(% style="width:148px" %)4|(% style="width:386px" %)4 17 +(% style="width:393px" %) 18 +|**Circuit name**|(% style="width:148px" %)**Pin of the connector to BMS USB-RS485**|(% style="width:149px" %)**Pin of the connector to BMS Logic 18** 19 +|**RS485_A**|(% style="width:148px" %)1|(% style="width:149px" %)1 20 +|**RS485_B**|(% style="width:148px" %)2|(% style="width:149px" %)2 21 +|**+5V**|(% style="width:148px" %)3|(% style="width:149px" %)3 22 +|**GND**|(% style="width:148px" %)4|(% style="width:149px" %)4 22 22 23 23 === 3.1.2 Cells cable === 24 24 25 -[[image:1733151480875-350.png||data-xwiki-image-style-alignment="center" height="1 26" width="656"]]26 +[[image:1733151480875-350.png||data-xwiki-image-style-alignment="center" height="137" width="713"]] 26 26 27 27 [[image:1733151480876-978.png||data-xwiki-image-style-alignment="center" height="224" width="441"]] 28 28 ... ... @@ -50,20 +50,20 @@ 50 50 |**C17**|(% style="width:151px" %)21|(% style="width:152px" %)20 51 51 |**C18**|(% style="width:151px" %)10|(% style="width:152px" %)10 52 52 53 -3.2 Setting device address 54 +== 3.2 Setting device address == 54 54 55 55 Launch the ElectricDeviceMonitor, then select the “BMS Logic 12/18 3.x” monitor: 56 56 57 -[[image:1733151480877-266.png||data-xwiki-image-style-alignment="center" height=" 267" width="244"]]58 +[[image:1733151480877-266.png||data-xwiki-image-style-alignment="center" height="351" width="321"]] 58 58 59 59 Select the following settings to connect to the BMS Logic 18: 115200 bps, 8 bits, no parity, 1 stop bit, device address 247. The address 247 is a service address that the device will always answer. 60 60 61 -[[image:1733151480878-434.png||data-xwiki-image-style-alignment="center" height="2 48" width="450"]]62 +[[image:1733151480878-434.png||data-xwiki-image-style-alignment="center" height="263" width="477"]] 62 62 63 63 Check the connection with the BMS Logic 18 is established. 64 64 65 65 Set the needed device address and click the “Save” button: 66 66 67 -[[image:1733151480878-552.png||data-xwiki-image-style-alignment="center" height="4 32" width="663"]]68 +[[image:1733151480878-552.png||data-xwiki-image-style-alignment="center" height="461" width="707"]] 68 68 69 69