2. Installation and connection

Version 2.1 by Admin on 2024/12/02 14:50

​​​​​2.1 Installation procedure

The mounting area of the BMS Logic 18 must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Logic 18 is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation.

The installation site must provide convenient access for subsequent connection to the device’s headers.

The BMS Logic 18 has a heat sink to dissipate the heat generated during the balancing of the cells. When used in enclosed enclosures, heat must be removed from the sink, otherwise it may damage the device.

Overall and mounting dimensions of the BMS Logic 18 are shown below.

1733150108388-179.png

ParameterValue

Overall dimensions (length × width × height), mm

214 × 140 × 16 
Mounting dimensions (length × width), mm198 × 132
Mounting holesM4
Headers X1-X5 typeMolex series Micro-Fit

2.2 Headers

The BMS Logic 18 is designed to measure temperature and voltage of 18 battery cells.

1733150257403-684.png

2.2.1 X1 – header for cells

1733150257406-647.jpeg

PinNameDescription
1V-Minus of the cell stack
2C2Cell #2
3C4Cell #4
4C6Cell #6
5C8Cell #8
6C10Cell #10
7C12Cell #12
8C14Cell #14
9C16Cell #16
10C18Cell #18 (maximum potential of the cell stack)
11--
12C1Cell #1 (minimum potential with respect to V-)
13C3Cell #3
14C5Cell #5
15C7Cell #7
16C9Cell #9
17C11Cell #11
18C13Cell #13
19C15Cell #15
20C17Cell #17

2.2.2 X2 – header 1 for temperature sensors

1733150257408-172.jpeg

PinNameDescription
1TEMPG9Ground of the thermistor #9
2TEMPG8Ground of the thermistor #8
3TEMPG7Ground of the thermistor #7
4TEMPG6Ground of the thermistor #6
5TEMPG5Ground of the thermistor #5
6TEMPG4Ground of the thermistor #4
7TEMPG3Ground of the thermistor #3
8TEMPG2Ground of the thermistor #2
9TEMPG1Ground of the thermistor #1
10TEMP9Signal from the thermistor #9
11TEMP8Signal from the thermistor #8
12TEMP7Signal from the thermistor #7
13TEMP6Signal from the thermistor #6
14TEMP5Signal from the thermistor #5
15TEMP4Signal from the thermistor #4
16TEMP3Signal from the thermistor #3
17TEMP2Signal from the thermistor #2
18TEMP1Signal from the thermistor #1

2.2.3 X3 – header 2 for temperature sensors

1733150257410-796.jpeg

PinNameDescription
1TEMPG18Ground of the thermistor #18
2TEMPG17Ground of the thermistor #17
3TEMPG16Ground of the thermistor #16
4TEMPG15Ground of the thermistor #15
5TEMPG14Ground of the thermistor #14
6TEMPG13Ground of the thermistor #13
7TEMPG12Ground of the thermistor #12
8TEMPG11Ground of the thermistor #11
9TEMPG10Ground of the thermistor #10
10TEMP18Signal from the thermistor #18
11TEMP17Signal from the thermistor #17
12TEMP16Signal from the thermistor #16
13TEMP15Signal from the thermistor #15
14TEMP14Signal from the thermistor #14
15TEMP13Signal from the thermistor #13
16TEMP12Signal from the thermistor #12
17TEMP11Signal from the thermistor #11
18TEMP10Signal from the thermistor #10

2.3.4 X4, X5 – headers for communication with BMS Main

1733150513230-598.png

PinNameDescription
1RS485_ARS-485 line A for communication with the BMS Main
2RS485_BRS-485 line B for communication with the BMS Main
3+5VSupply voltage 5V
4GNDGround

2.4 Switches and Indicators

2.4.1 SWD1 – address switch

Switch numberDescription
1The first (the lowest) bit of the address. Position ON - bit is 1
2The second bit is the address. Position ON - bit is 1
3The third bit of the address. Position ON - bit is 1
4The fourth bit of the address. Position ON - bit is 1
5The fifth (the highest) bit of the address. Position ON - bit is 1

Note: There is no SWD1 switch in the recent revisions of the BMS Logic 18. The device address must be configured in the settings (see the section 4.2 Configuration procedure).

2.4.2 SWD2 – RS-485 termination resistor switch

To connect the termination resistor between the RS485_A and RS485_B lines, switch SWD2 to the ON position.

Note: There is no SWD2 switch in the recent revisions of the BMS Logic 18. Connect a 120 Ohm termination resistor directly to the X5 connector between the lines RS485_A and RS485_B.

2.4.3 DS1 – mode indicator

StateDescription
BlinkingConnection between the BMS Main and the device is established
Short flashing (~50 milliseconds in a second)The device is measuring voltage and temperature. No communication between the BMS Main and the device
Long flashing (1 second in a 2 second period)The device is in the bootloader mode