Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 13:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Logic 18.WebHome1 +drafts.BMS Logic 18.WebHome - Content
-
... ... @@ -1,19 +1,5 @@ 1 -(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Installation and connection = 1 +== 2.1 Installation procedure == 3 3 4 -== Safety rules == 5 - 6 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 7 - 8 -It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series. 9 - 10 -(% class="box errormessage" %) 11 -((( 12 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 -))) 14 - 15 -== Installation procedure == 16 - 17 17 The mounting area of the BMS Logic 18 must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Logic 18 is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation. 18 18 19 19 The installation site must provide convenient access for subsequent connection to the device’s headers. ... ... @@ -22,7 +22,7 @@ 22 22 23 23 Overall and mounting dimensions of the BMS Logic 18 are shown below. 24 24 25 -[[image:173 6771889450-259.png||data-xwiki-image-style-alignment="center" height="405" width="600"]]11 +[[image:1733150108388-179.png||data-xwiki-image-style-alignment="center" height="384" width="555"]] 26 26 27 27 |**Parameter**|**Value** 28 28 |((( ... ... @@ -30,23 +30,16 @@ 30 30 )))|214 × 140 × 16 31 31 |Mounting dimensions (length × width), mm|198 × 132 32 32 |Mounting holes|M4 19 +|Headers X1-X5 type|Molex series Micro-Fit 33 33 34 -== Headers == 21 +== (% style="color:#333333" %)2.2 (%%)Headers == 35 35 36 36 The BMS Logic 18 is designed to measure temperature and voltage of 18 battery cells. 37 37 38 -[[image:173 6770801015-488.png||data-xwiki-image-style-alignment="center" height="350" width="600"]]25 +[[image:1733150257403-684.png||data-xwiki-image-style-alignment="center" height="376" width="640"]] 39 39 40 -(% class="box warningmessage" %) 41 -((( 42 -**Attention!** 43 -All headers are shown from the device side! 44 -))) 27 +=== 2.2.1 X1 – header for cells === 45 45 46 -=== X1 – header for cells === 47 - 48 -Receptacle Housing: Molex 430252000. Terminals: Molex 43030 49 - 50 50 [[image:1733150257406-647.jpeg||data-xwiki-image-style-alignment="center" height="73" width="256"]] 51 51 52 52 |**Pin**|**Name**|**Description** ... ... @@ -71,10 +71,8 @@ 71 71 |**19**|**C15**|Cell #15 72 72 |**20**|**C17**|Cell #17 73 73 74 -=== X2 – header 1 for temperature sensors === 53 +=== 2.2.2 X2 – header 1 for temperature sensors === 75 75 76 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030 77 - 78 78 [[image:1733150257408-172.jpeg||data-xwiki-image-style-alignment="center" height="81" width="267"]] 79 79 80 80 |**Pin**|**Name**|**Description** ... ... @@ -97,10 +97,8 @@ 97 97 |**17**|**TEMP2**|Signal from the thermistor #2 98 98 |**18**|**TEMP1**|Signal from the thermistor #1 99 99 100 -== =X3 – header 2 for temperature sensors ===77 +== 2.2.3 X3 – header 2 for temperature sensors == 101 101 102 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030 103 - 104 104 [[image:1733150257410-796.jpeg||data-xwiki-image-style-alignment="center" height="81" width="268"]] 105 105 106 106 |**Pin**|**Name**|**Description** ... ... @@ -123,10 +123,8 @@ 123 123 |**17**|**TEMP11**|Signal from the thermistor #11 124 124 |**18**|**TEMP10**|Signal from the thermistor #10 125 125 126 -=== X4, X5 – headers for communication with BMS Main === 101 +=== 2.3.4 X4, X5 – headers for communication with BMS Main === 127 127 128 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 129 - 130 130 [[image:1733150513230-598.png||data-xwiki-image-style-alignment="center" height="89" width="81"]] 131 131 132 132 |**Pin**|**Name**|**Description** ... ... @@ -135,9 +135,9 @@ 135 135 |**3**|**+5V**|Supply voltage 5V 136 136 |**4**|**GND**|Ground 137 137 138 -== Switches and Indicators == 111 +== 2.4 Switches and Indicators == 139 139 140 -=== SWD1 – address switch === 113 +=== 2.4.1 SWD1 – address switch === 141 141 142 142 |**Switch number**|**Description** 143 143 |**1**|The first (the lowest) bit of the address. Position ON - bit is 1 ... ... @@ -148,10 +148,10 @@ 148 148 149 149 (% class="box infomessage" %) 150 150 ((( 151 -**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 18. The device address must be configured in the settings (see the section [[3. Configuration>>doc:Batterymanagement systems.BMS Logic18.3\. Configuration.WebHome]]).124 +**Note: **There is no SWD1 switch in the recent revisions of the BMS Logic 18. The device address must be configured in the settings (see the section 4.2 Configuration procedure). 152 152 ))) 153 153 154 -=== SWD2 – RS-485 termination resistor switch === 127 +=== 2.4.2 SWD2 – RS-485 termination resistor switch === 155 155 156 156 To connect the termination resistor between the **RS485_A** and **RS485_B** lines, switch SWD2 to the ON position. 157 157 ... ... @@ -160,51 +160,9 @@ 160 160 **Note: **There is no SWD2 switch in the recent revisions of the BMS Logic 18. Connect a 120 Ohm termination resistor directly to the X5 connector between the lines RS485_A and RS485_B. 161 161 ))) 162 162 163 -=== DS1 – mode indicator === 136 +=== 2.4.3 DS1 – mode indicator === 164 164 165 -(% style="width:551px" %) 166 -|(% style="width:188px" %)**State**|(% style="width:362px" %)**Description** 167 -|(% style="width:188px" %)**Blinking**|(% style="width:362px" %)Connection between the BMS Main and the device is established 168 -|(% style="width:188px" %)**Short flashing (~~50 milliseconds in a second)**|(% style="width:362px" %)The device is measuring voltage and temperature. No communication between the BMS Main and the device 169 -|(% style="width:188px" %)**Long flashing (1 second in a 2 second period)**|(% style="width:362px" %)The device is in the bootloader mode 170 - 171 -== Connection procedure == 172 - 173 -=== Connection to BMS Main === 174 - 175 -To connect the BMS Main to BMS Logic 18 do the following steps: 176 - 177 -1. Connect the BMS Main to the first BMS Logic 18 (P15 -> X4); 178 -1. Connect the BMS Logic 18 to each other (X5 -> X4); 179 -1. Switch SWD2 on the last BMS Logic 18 to the ON position or connect a 120 Ohm termination resistor directly to the X5 connector of the last BMS Logic 18. 180 - 181 -(% class="box infomessage" %) 182 -((( 183 -**Recommendations:** 184 -~1. The total cable length (the sum of the lengths of all cables) between the BMS Main and the last BMS Logic 18 should not exceed 500 meters. 185 -2. Make all connections with the same cable. 186 -3. For a total cable length of more than 10 meters use twisted pair with the 120 Ohm wave impedance. 187 -))) 188 - 189 -=== Connecting battery cells === 190 - 191 -To connect the battery cells, follow figure below. Incorrect connection of the cells can damage the BMS Logic 18. 192 - 193 -Begin the connection with the negative of the battery: the "V-" of the first BMS Logic 18 is connected to "B-", then the first cell (C1) of the battery is connected, then the second (C2), etc. The “V-“ of the next BMS Logic 18 is connected to the C18 of the previous BMS Logic 18. If not all inputs of the cells are used, then the remaining inputs are connected to the cell with the most potential. 194 - 195 - 196 -[[image:1733151263524-832.jpeg||data-xwiki-image-style-alignment="center" height="492" width="612"]] 197 - 198 -(% class="box warningmessage" %) 199 -((( 200 -**Attention!** 201 -Connect the battery according to the diagram, otherwise the device may be damaged! 202 -))) 203 - 204 -=== Connecting thermistors === 205 - 206 -Thermistors should be fastened to the cells, excluding short circuits to the cell terminals (for example, isolate thermistors with heat shrink). For reliable operation, it is recommended to use all thermistors (a temperature sensor per cell). 207 - 208 -[[image:1733231170607-745.png||data-xwiki-image-style-alignment="center" height="324" width="806"]] 209 - 210 - 138 +|**State**|**Description** 139 +|**Blinking**|Connection between the BMS Main and the device is established 140 +|**Short flashing (~~50 milliseconds in a second)**|The device is measuring voltage and temperature. No communication between the BMS Main and the device 141 +|**Long flashing (1 second in a 2 second period)**|The device is in the bootloader mode
- 1733151263524-832.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -114.2 KB - Content
- 1733231170607-745.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -254.4 KB - Content
- 1736770801015-488.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -26.0 KB - Content
- 1736771889450-259.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.9 KB - Content