3. Configuration

Last modified by Admin on 2025/10/21 20:51

Configuration

Connecting device to PC

To connect the BMS Logic 12S to a PC, use the BMS USB-RS485 adapter. It allows to power and communicate with the BMS Logic 12S:

  1. Connect the BMS USB-RS485 to the BMS Logic 12S:
    a) the communication circuits (X3 -> X3);
    b) the circuits of cells (X5 -> X1).
  2. Connect the BMS USB-RS485 to a PC using a mini-USB or USB-C cable.
  3. Turn all the BMS USB-RS485’s switches to the “I” position.

The assembly drawings of the harnesses between the BMS USB-RS485 and BMS Logic 12S are given below.

Communication and power cable

1733242534258-448.pngThe wires of the communication and power cable must be connected according to the following table:

Circuit namePin of the connector to BMS USB-RS485Pin of the connector to BMS Logic 12S
RS485_A12
RS485_B21
+5V34
GND43

Cells cable

1733243443148-978.pngThe wires of the cells cable must be connected according to the following table:

Circuit namePin of the connector to BMS USB-RS485Pin of the connector to BMS Logic 12S
V-19
C1131
C2210
C3142
C4311
C51512
C643
C7513
C864
C9714
C10815
C11916
C121017

Setting the device address

Launch the ElectricDeviceMonitor, then select the “BMS Logic 12/18 3.x” monitor:

1733145551346-396.png

Set the following settings to connect to the BMS Logic 12S:

  • 115200 bps,
  • 8 bits,
  • no parity,
  • 1 stop bit,
  • device address 247.

The address 247 is a service address that the device will always answer.

1733145551347-494.png

Check the connection with the BMS Logic 12S is established.

Set the needed device address and click the “Save” button:

1733145551348-226.png