1. Technical specifications

Last modified by Admin on 2025/05/12 11:13

echnical specifications

1746620257874-435.png

BMS Logic 12 represents the second generation of measuring modules that takes the best from BMS Logic 2.0 and offers greater accuracy and energy efficiency. It determines voltage and temperature of the battery cells and does passive balancing of the cells on a command from the BMS controller.

Specifications

ParameterValue
Supply voltage, V5.0 ± 0.5
Current consumption @5 V, mA (maximum)10
Cell stack voltage, V11 to 52
Power consumption @Cell stack, mW (maximum)200
Number of cells4 to 12
Balancing current @4.2 V on a cell, mA (average)350
Cell voltage measurement error, V (maximum)±0.003
Cell temperature measurement error, °С (maximum)±2
Dimensions (length × width × height), mm139 × 126 × 16 
Weight, g250 ± 20
Operating temperature range, ºС-40 to +85
Rated insulation voltage between communication lines and cell stack lines, AC 50Hz, 1 minute, VRMS (minimum)3500
Headers X1-X4 typeMolex series Micro-Fit

Overall and mounting dimensions

1746622870523-241.png