Wiki source code of BMS LANmodule
Last modified by Admin on 2025/05/12 11:26
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | = General information = | ||
2 | |||
3 | [[image:1734099407734-687.png||data-xwiki-image-style-alignment="center" height="167" width="300"]] | ||
4 | |||
5 | BMS LANmodule is an extension module that can be inserted to the BMS Mini, BMS Mini S, BMS Main 3, BMS Main X, or BMS Main 3X controller. It allows a BMS controller to be configured over an Ethernet network. | ||
6 | |||
7 | (% id="cke_bm_4104S" style="display:none" %) (%%)Overall architecture of a battery system that is controlled by an upper-level system via Ethernet is shown below. | ||
8 | |||
9 | [[image:1734099501895-554.png||data-xwiki-image-style-alignment="center" height="344" width="450"]] | ||
10 | |||
11 | = Specifications = | ||
12 | |||
13 | |**Parameter**|**Value** | ||
14 | |Supply voltage, V|5.0 ± 0.5 | ||
15 | |Current consumption, mA, max|200 | ||
16 | |Network speed, Mbps|10/100 | ||
17 | |Dimensions (length × width × height), mm|44 × 42 × 24 | ||
18 | |Weight, g|14 ± 5 | ||
19 | |(% colspan="2" %)**Operating conditions** | ||
20 | |Operating temperature range, ° С|-40 to +85 | ||
21 | |Degree of protection from external influences|IP00 | ||
22 | |||
23 | = Connection procedure = | ||
24 | |||
25 | (% class="box warningmessage" %) | ||
26 | ((( | ||
27 | **Attention!** | ||
28 | Connecting the BMS LANmodule is performed to the powered-off BMS controller! | ||
29 | To prevent the damage of device avoid electrostatic discharges. | ||
30 | ))) | ||
31 | |||
32 | The BMS LANmodule must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws. | ||
33 | |||
34 | Here is the example of header for additional devices on BMS Main X: | ||
35 | |||
36 | [[image:1734099661846-836.png||data-xwiki-image-style-alignment="center" height="423" width="450"]] | ||
37 | |||
38 | = Configuration = | ||
39 | |||
40 | Configuration of the BMS LANmodule must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings located in the “Connectivity -> LAN” section of the settings. | ||
41 | |||