Changes for page BMS LANmodule
Last modified by Admin on 2025/05/12 11:26
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.WebHome1 +drafts.WebHome - Content
-
... ... @@ -1,8 +1,10 @@ 1 1 = General information = 2 2 3 + 4 + 3 3 [[image:1734099407734-687.png||data-xwiki-image-style-alignment="center" height="167" width="300"]] 4 4 5 -BMS LANmodule is an extension module that can be inserted to the BMS Mini, BMS Mini S, BMS Main 3, BMS Main X,or BMS Main3X controller. It allows a BMS controller to be configured over an Ethernet network.7 +BMS LANmodule is an extension module that can be inserted to the BMS Mini, BMS Mini S, BMS Main 3, or BMS Main X controller. It allows a BMS controller to be configured over an Ethernet network. 6 6 7 7 (% id="cke_bm_4104S" style="display:none" %) (%%)Overall architecture of a battery system that is controlled by an upper-level system via Ethernet is shown below. 8 8 ... ... @@ -28,9 +28,9 @@ 28 28 Connecting the BMS LANmodule 1.x is performed to the powered-off BMS controller! 29 29 ))) 30 30 31 -The BMS LANmodule must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws. 33 +The BMS LANmodule 1.x must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws. 32 32 33 -Here is the example of header for additionaldevices onBMS Main X:35 +Here is the example of BMS Wi-Fi header on BMS Main X: 34 34 35 35 [[image:1734099661846-836.png||data-xwiki-image-style-alignment="center" height="423" width="450"]] 36 36 ... ... @@ -37,10 +37,8 @@ 37 37 = Configuration = 38 38 39 39 40 -Configuration of the BMS LANmodule must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. 42 +Configuration of the BMS LANmodule 1.x must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings are in the “Connectivity -> LAN” section of the settings. 41 41 42 -Typically, the connection settings located in the “Connectivity -> LAN” section of the settings. 43 - 44 44 (% class="box warningmessage" %) 45 45 ((( 46 46 To apply new connection settings, it is necessary to restart the BMS controller.