Changes for page BMS LANmodule
Last modified by Admin on 2025/05/12 11:26
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,7 +2,7 @@ 2 2 3 3 [[image:1734099407734-687.png||data-xwiki-image-style-alignment="center" height="167" width="300"]] 4 4 5 -BMS LANmodule is an extension module that can be inserted to the BMS Mini, BMS Mini S, BMS Main 3, BMS Main 3X, or BMS Main X controller. It allows a BMS controller to be configured over an Ethernet network.5 +BMS LANmodule is an extension module that can be inserted to the BMS Mini, BMS Mini S, BMS Main 3, BMS Main X, or BMS Main 3X controller. It allows a BMS controller to be configured over an Ethernet network. 6 6 7 7 (% id="cke_bm_4104S" style="display:none" %) (%%)Overall architecture of a battery system that is controlled by an upper-level system via Ethernet is shown below. 8 8 ... ... @@ -15,7 +15,7 @@ 15 15 |Current consumption, mA, max|200 16 16 |Network speed, Mbps|10/100 17 17 |Dimensions (length × width × height), mm|44 × 42 × 24 18 -|Weight, g|14 ± 218 +|Weight, g|14 ± 5 19 19 |(% colspan="2" %)**Operating conditions** 20 20 |Operating temperature range, ° С|-40 to +85 21 21 |Degree of protection from external influences|IP00 ... ... @@ -25,21 +25,21 @@ 25 25 (% class="box warningmessage" %) 26 26 ((( 27 27 **Attention!** 28 -Connecting the BMS LANmodule 1.x is performed to the powered-off BMS controller! 28 +Connecting the BMS LANmodule is performed to the powered-off BMS controller! 29 +To prevent the damage of device avoid electrostatic discharges. 29 29 ))) 30 30 31 -The BMS LANmodule 1.xmust be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws.32 +The BMS LANmodule must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws. 32 32 33 -Here is the example of BMS Wi-Fiheader on BMS Main X:34 +Here is the example of header for additional devices on BMS Main X: 34 34 35 35 [[image:1734099661846-836.png||data-xwiki-image-style-alignment="center" height="423" width="450"]] 36 36 37 37 = Configuration = 38 38 40 +Configuration of the BMS LANmodule must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings located in the “Connectivity -> LAN” section of the settings. 39 39 40 -Configuration of the BMS LANmodule 1.x must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings are in the “Connectivity -> LAN” section of the settings. 41 - 42 -(% class="box warningmessage" %) 42 +(% class="box infomessage" %) 43 43 ((( 44 44 To apply new connection settings, it is necessary to restart the BMS controller. 45 45 )))
- 1737045696448-626.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.3 KB - Content