... ... @@ -15,7 +15,7 @@
15 15  |Current consumption, mA, max|200
16 16  |Network speed, Mbps|10/100
17 17  |Dimensions (length × width × height), mm|44 × 42 × 24
18 -|Weight, g|14 ± 5
18 +|Weight, g|14 ± 2
19 19  |(% colspan="2" %)**Operating conditions**
20 20  |Operating temperature range, ° С|-40 to +85
21 21  |Degree of protection from external influences|IP00
... ... @@ -25,21 +25,21 @@
25 25  (% class="box warningmessage" %)
26 26  (((
27 27  **Attention!**
28 -Connecting the BMS LANmodule is performed to the powered-off BMS controller!
29 -To prevent the damage of device avoid electrostatic discharges.
28 +Connecting the BMS LANmodule 1.x is performed to the powered-off BMS controller!
30 30  )))
31 31  
32 -The BMS LANmodule must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws.
31 +The BMS LANmodule 1.x must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws.
33 33  
34 -Here is the example of header for additional devices on BMS Main X:
33 +Here is the example of BMS Wi-Fi header on BMS Main X:
35 35  
36 36  [[image:1734099661846-836.png||data-xwiki-image-style-alignment="center" height="423" width="450"]]
37 37  
38 38  = Configuration =
39 39  
40 -Configuration of the BMS LANmodule must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings located in the “Connectivity -> LAN” section of the settings.
41 41  
42 -(% class="box infomessage" %)
40 +Configuration of the BMS LANmodule 1.x must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings are in the “Connectivity -> LAN” section of the settings.
41 +
42 +(% class="box warningmessage" %)
43 43  (((
44 44  To apply new connection settings, it is necessary to restart the BMS controller.
45 45  )))