Changes for page BMS LANmodule
Last modified by Admin on 2025/05/12 11:26
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.WebHome1 +drafts.WebHome - Content
-
... ... @@ -1,11 +1,9 @@ 1 -= Общаяинформация=1 += General information = 2 2 3 3 [[image:1734099407734-687.png||data-xwiki-image-style-alignment="center" height="167" width="300"]] 4 4 5 -BMS LANmodule представляетсобоймодульрасширения,которыйустанавливаетсявконтроллерыBMS Mini, BMS Mini S, BMS MainX, BMS Main3илиBMSОнпозволяетнастраиватьBMSчерезсетьEthernet.5 +BMS LANmodule is an extension module that can be inserted to the BMS Mini, BMS Mini S, BMS Main 3, BMS Main X, or BMS Main 3X controller. It allows a BMS controller to be configured over an Ethernet network. 6 6 7 -Устройство не содержит функций шифрования и криптографии, а также не содержит батареек/аккумуляторов. 8 - 9 9 (% id="cke_bm_4104S" style="display:none" %) (%%)Overall architecture of a battery system that is controlled by an upper-level system via Ethernet is shown below. 10 10 11 11 [[image:1734099501895-554.png||data-xwiki-image-style-alignment="center" height="344" width="450"]] ... ... @@ -12,15 +12,15 @@ 12 12 13 13 = Specifications = 14 14 15 -|** Параметр**|**Значение**16 -| Напряжениепитания,В|5,0 ± 0,517 -| Потребляемыйток,мА,не более|20018 -| Скоростьподключения,Мбит/с|10/10019 -| Габариты(длина×ширина×высота),мм|44 × 42 × 2420 -| Масса,г|14 ± 221 -|(% colspan="2" %)** Условияэксплуатации**22 -| Диапазонрабочихтемператур, °С|от-40до+8523 -| Степеньзащитыотвнешнихвоздействий|IP0013 +|**Parameter**|**Value** 14 +|Supply voltage, V|5.0 ± 0.5 15 +|Current consumption, mA, max|200 16 +|Network speed, Mbps|10/100 17 +|Dimensions (length × width × height), mm|44 × 42 × 24 18 +|Weight, g|14 ± 2 19 +|(% colspan="2" %)**Operating conditions** 20 +|Operating temperature range, ° С|-40 to +85 21 +|Degree of protection from external influences|IP00 24 24 25 25 = Connection procedure = 26 26 ... ... @@ -39,10 +39,8 @@ 39 39 = Configuration = 40 40 41 41 42 -Configuration of the BMS LANmodule must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. 40 +Configuration of the BMS LANmodule must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings located in the “Connectivity -> LAN” section of the settings. 43 43 44 -Typically, the connection settings located in the “Connectivity -> LAN” section of the settings. 45 - 46 46 (% class="box warningmessage" %) 47 47 ((( 48 48 To apply new connection settings, it is necessary to restart the BMS controller.
- 1737045468422-732.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.3 KB - Content