Changes for page BMS LANmodule

Last modified by Admin on 2025/05/12 11:26

From version 1.1
edited by Admin
on 2024/12/13 14:24
Change comment: There is no comment for this version
To version 16.1
edited by Admin
on 2025/05/12 11:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,10 +1,8 @@
1 1  = General information =
2 2  
3 -
4 -
5 5  [[image:1734099407734-687.png||data-xwiki-image-style-alignment="center" height="167" width="300"]]
6 6  
7 -BMS LANmodule is an extension module that can be inserted to the BMS Mini, BMS Mini S, BMS Main 3, or BMS Main X controller. It allows a BMS controller to be configured over an Ethernet network.
5 +BMS LANmodule is an extension module that can be inserted to the BMS Mini, BMS Mini S, BMS Main 3, BMS Main X, or BMS Main 3X controller. It allows a BMS controller to be configured over an Ethernet network.
8 8  
9 9  (% id="cke_bm_4104S" style="display:none" %) (%%)Overall architecture of a battery system that is controlled by an upper-level system via Ethernet is shown below.
10 10  
... ... @@ -17,7 +17,7 @@
17 17  |Current consumption, mA, max|200
18 18  |Network speed, Mbps|10/100
19 19  |Dimensions (length × width × height), mm|44 × 42 × 24
20 -|Weight, g|14 ± 2
18 +|Weight, g|14 ± 5
21 21  |(% colspan="2" %)**Operating conditions**
22 22  |Operating temperature range, ° С|-40 to +85
23 23  |Degree of protection from external influences|IP00
... ... @@ -27,21 +27,21 @@
27 27  (% class="box warningmessage" %)
28 28  (((
29 29  **Attention!**
30 -Connecting the BMS LANmodule 1.x is performed to the powered-off BMS controller!
28 +Connecting the BMS LANmodule is performed to the powered-off BMS controller!
29 +To prevent the damage of device avoid electrostatic discharges.
31 31  )))
32 32  
33 -The BMS LANmodule 1.x must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws.
32 +The BMS LANmodule must be inserted into the corresponding header of the BMS controller. The device must be fixed to the BMS controller by **11mm M3 standoffs** and M3 screws.
34 34  
35 -Here is the example of BMS Wi-Fi header on BMS Main X:
34 +Here is the example of header for additional devices on BMS Main X:
36 36  
37 37  [[image:1734099661846-836.png||data-xwiki-image-style-alignment="center" height="423" width="450"]]
38 38  
39 39  = Configuration =
40 40  
40 +Configuration of the BMS LANmodule must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings located in the “Connectivity -> LAN” section of the settings.
41 41  
42 -Configuration of the BMS LANmodule 1.x must be done according to the BMS controller’s configuration manual, see [[Battery management systems>>path:/bin/view/Battery%20management%20systems/]]. Typically, the connection settings are in the “Connectivity -> LAN” section of the settings.
43 -
44 -(% class="box warningmessage" %)
42 +(% class="box infomessage" %)
45 45  (((
46 46  To apply new connection settings, it is necessary to restart the BMS controller.
47 47  )))
1737045696448-626.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +10.3 KB
Content