2. Installation and connection

Last modified by Admin on 2025/03/18 12:35

Installation and connection

Safety rules

Before use, configure the system. Proper operation of the device is possible only if it is correctly configured.

To prevent the damage of device avoid electrostatic discharges while working with the device.

Installation

Overall and mounting dimensions of BMS Indication are shown on figure below:

1734104601122-708.png

ParameterValue
Overall dimensions (length × width × height), mm61 × 49 × 27
Mounting dimensions (length × width), mm55 × 43
Mounting holesM3

Headers

The BMS Indication has two headers for connecting the BMS (P2 and P3), a header for connecting external equipment (a PC, for example), and a switch which connects a terminal resistor to the CAN bus (SWD1).

P2, P3 – headers for communication with BMS

Receptacle Housing: Molex 39012040. Terminals: Molex 5556

1734104743581-727.png

PinNameDescription
1CANHCAN H line for communication with the BMS controller
2CANLCAN L line for communication with the BMS controller
3+5VSupply voltage 5 V
4GNDGround

J1 – header for external equipment

1734104763162-358.png

PinNameDescription
1--
2CANLCAN L line for communication with external equipment
3--
4--
5--
6GNDGround
7CANHCAN H line for communication with external equipment
8--
9--

SWD1 – CAN terminal resistor switch

To connect the terminal resistor between the CANH and CANL lines, switch the SWD1 to the ON position.