Wiki source code of 2. Installation and connection
Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
1.1 | 1 | (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) |
2 | = Connection = | ||
3 | |||
![]() |
2.1 | 4 | == Installation == |
![]() |
1.1 | 5 | |
6 | The mounting location must be protected from mechanical obstacles (dust, dirt, large objects) and water. Device placement should provide easy access for connection. | ||
7 | |||
8 | [[image:1734009150929-282.png||data-xwiki-image-style-alignment="center" height="414" width="600"]] | ||
9 | |||
10 | |**Parameter**|**Value** | ||
11 | |Overall dimensions (length × width × height), mm|140 × 60 × 14 | ||
12 | |Mounting dimensions (length × width), mm|130 × 50 | ||
13 | |Mounting holes|M3 | ||
14 | |||
15 | == Headers == | ||
16 | |||
![]() |
4.1 | 17 | The BMS IMD has two headers for connecting the power line (X3 and X4), a header for connecting external equipment and power supply (X2), a chassis connection header (X1) and a jumper which connects a terminal resistor to the CAN bus (J1). |
![]() |
1.1 | 18 | |
19 | [[image:1734009150915-999.png||data-xwiki-image-style-alignment="center" height="267" width="600"]] | ||
20 | |||
21 | |||
22 | === X1 – header for chassis connection === | ||
23 | |||
![]() |
7.1 | 24 | Receptacle Housing: Molex 430250200. Terminals: Molex 43030 |
![]() |
4.2 | 25 | |
![]() |
1.1 | 26 | [[image:1734009337118-173.png||data-xwiki-image-style-alignment="center"]] |
27 | |||
28 | |||
29 | |**Pin**|**Name**|**Description** | ||
30 | |**1**|**CHASSIS**|Vehicle chassis connection | ||
31 | |**2**|**CHASSIS**|Vehicle chassis connection | ||
32 | |||
33 | === X2 – header for a top-level controller (rev1.1 only) === | ||
34 | |||
![]() |
7.1 | 35 | Receptacle Housing: Molex 430250800. Terminals: Molex 43030 |
![]() |
4.2 | 36 | |
![]() |
1.1 | 37 | [[image:1734009150925-152.png||data-xwiki-image-style-alignment="center" height="79" width="120"]] |
38 | |||
39 | |**Pin**|**Name**|**Description** | ||
40 | |**1**|**GND**|Ground | ||
41 | |**2**|**CAN_H**|CAN H line for communication with external equipment | ||
42 | |**3**|**GND**|Ground | ||
43 | |**4**|**GND**|Ground | ||
44 | |**5**|**V+**|Device supply line (9-32V) | ||
45 | |**6**|**CAN_L**|CAN L line for communication with external equipment | ||
46 | |**7**|**OUT_WORK**|Discrete output for work indication (open drain, max 60V, 1A) | ||
47 | |**8**|**OUT_ERROR**|Discrete output for error indication (open drain, max 60V, 1A) | ||
48 | |||
49 | (% class="box infomessage" %) | ||
50 | ((( | ||
51 | **Notes:** | ||
52 | The **OUT_WORK **signal signals the operation of the device’s main program and is generated when the device is turned on. | ||
53 | The **OUT_ERROR **signal indicates a critical device error or a low insulation resistance value. | ||
54 | ))) | ||
55 | |||
56 | === X2 – header for a top-level controller (rev1.2 only) === | ||
57 | |||
![]() |
7.1 | 58 | Receptacle Housing: Molex 430251200. Terminals: Molex 43030 |
![]() |
4.2 | 59 | |
![]() |
1.1 | 60 | [[image:1734009150926-839.png||data-xwiki-image-style-alignment="center" height="92" width="198"]] |
61 | |||
62 | |**Pin**|**Name**|**Description** | ||
63 | |**1**|**GND**|Ground | ||
64 | |**2**|**CAN_H**|CAN H line for communication with external equipment | ||
65 | |**3**|**GND**|Ground | ||
66 | |**4**|**GND**|Ground | ||
67 | |**5**|**GND**|Ground | ||
68 | |**6**|**GND**|Ground | ||
69 | |**7**|**V+**|Device supply line (9-32V) | ||
70 | |**8**|**CAN_L**|CAN L line for communication with external equipment | ||
71 | |**9**|**OUT_WORK**|Discrete output for work indication (open drain, max 42V, 1A) | ||
72 | |**10**|**OUT_ERROR**|Discrete output for error indication (open drain, max 42V, 1A) | ||
73 | |**11**|**KEYRUN_1**|Device power on signal | ||
74 | |**12**|**KEYRUN_2**|Device power on signal | ||
75 | |||
76 | (% class="box infomessage" %) | ||
77 | ((( | ||
78 | **Notes:** | ||
![]() |
3.1 | 79 | The **OUT_WORK **signal signals the operation of the device’s main program and is generated when the device is turned on. |
80 | The **OUT_ERROR **signal indicates a critical device error or a low insulation resistance value. | ||
81 | The **KEYRUN_1 **and **KEYRUN_2 **signals are equivalent and are intended to trigger the device’s power supply circuit. Can be connected to the V+ device supply line. | ||
![]() |
1.1 | 82 | ))) |
83 | |||
84 | === X3 – header for positive line connection === | ||
85 | |||
![]() |
7.1 | 86 | Receptacle Housing: Molex 436450200. Terminals: Molex 43030 |
![]() |
4.2 | 87 | |
![]() |
1.1 | 88 | [[image:1734009150927-865.png||data-xwiki-image-style-alignment="center" height="69" width="88"]] |
89 | |||
90 | |**Pin**|**Name**|**Description** | ||
91 | |**1**|**LINE+**|Positive line | ||
92 | |**2**|**LINE+**|Positive line | ||
93 | |||
94 | === X4 – header for negative line connection === | ||
95 | |||
![]() |
7.1 | 96 | Receptacle Housing: Molex 436450200. Terminals: Molex 43030 |
![]() |
4.2 | 97 | |
![]() |
1.1 | 98 | [[image:1734009150927-865.png||data-xwiki-image-style-alignment="center" height="69" width="88"]] |
99 | |||
100 | |||
101 | |**Pin**|**Name**|**Description** | ||
102 | |**1**|**LINE-**|Negative line | ||
103 | |**2**|**LINE-**|Negative line | ||
104 | |||
105 | === J1 – CAN terminal resistor jumper === | ||
106 | |||
107 | To connect the terminal resistor between the **CANH** and **CANL** lines, install jumper on pins 2 and 3 like shown on the picture below. | ||
108 | |||