Connection
Installation
The mounting location must be protected from mechanical obstacles (dust, dirt, large objects) and water. Device placement should provide easy access for connection.

Parameter | Value |
Overall dimensions (length × width × height), mm | 140 × 60 × 14 |
Mounting dimensions (length × width), mm | 130 × 50 |
Mounting holes | M3 |
Header types | Molex series Micro-Fit |
The BMS IMD 1.x has two headers for connecting the power line (X3 and X4), a header for connecting external equipment and power supply (X2), a chassis connection header (X1) and a jumper which connects a terminal resistor to the CAN bus (J1).


Pin | Name | Description |
1 | CHASSIS | Vehicle chassis connection |
2 | CHASSIS | Vehicle chassis connection |

Pin | Name | Description |
1 | GND | Ground |
2 | CAN_H | CAN H line for communication with external equipment |
3 | GND | Ground |
4 | GND | Ground |
5 | V+ | Device supply line (9-32V) |
6 | CAN_L | CAN L line for communication with external equipment |
7 | OUT_WORK | Discrete output for work indication (open drain, max 60V, 1A) |
8 | OUT_ERROR | Discrete output for error indication (open drain, max 60V, 1A) |
Notes:
The OUT_WORK signal signals the operation of the device’s main program and is generated when the device is turned on.
The OUT_ERROR signal indicates a critical device error or a low insulation resistance value.

Pin | Name | Description |
1 | GND | Ground |
2 | CAN_H | CAN H line for communication with external equipment |
3 | GND | Ground |
4 | GND | Ground |
5 | GND | Ground |
6 | GND | Ground |
7 | V+ | Device supply line (9-32V) |
8 | CAN_L | CAN L line for communication with external equipment |
9 | OUT_WORK | Discrete output for work indication (open drain, max 42V, 1A) |
10 | OUT_ERROR | Discrete output for error indication (open drain, max 42V, 1A) |
11 | KEYRUN_1 | Device power on signal |
12 | KEYRUN_2 | Device power on signal |
Notes:
The OUT_WORK signal signals the operation of the device’s main program and is generated when the device is turned on.
The OUT_ERROR signal indicates a critical device error or a low insulation resistance value.
The KEYRUN_1 and KEYRUN_2 signals are equivalent and are intended to trigger the device’s power supply circuit. Can be connected to the V+ device supply line.

Pin | Name | Description |
1 | LINE+ | Positive line |
2 | LINE+ | Positive line |

Pin | Name | Description |
1 | LINE- | Negative line |
2 | LINE- | Negative line |
J1 – CAN terminal resistor jumper
To connect the terminal resistor between the CANH and CANL lines, install jumper on pins 2 and 3 like shown on the picture below.