4. Indication

Version 7.3 by Admin on 2025/02/27 15:37

Indication

No connection with BMS

If there are no Heartbeat messages from the BMS controller over the CAN bus the following message will be output on the display:

1734103363078-519.png  

Sound signals are not emitted in this case.

BMS initialization

If the connection with the BMS controller is established and the BMS is in the initialization mode (during the initialization the current sensor is calibrating and the BMS Logic boards searching is performed), the second line of the display will contain zero values of the voltage, current and temperature:

1734102855336-616.png

Sound signals are not emitted in this case.

Battery discharging

If the battery is in the discharging mode (the current is zero or negative) and there are no errors, the first line of the display will contain the charge level and the second line will contain battery parameters: voltage, current and minimum/maximum temperature:

1734102877861-815.png

1734102885576-298.png

Note: Views with the minimum and maximum temperatures are changing every 2 seconds. To change them manually press the button on the device or an external button connected to the P6 header.

If the battery charge level is below the value set in the Low battery level signal (single beep) group, the device will emit a sound signal about the low battery charge level.

If the battery charge level is below the value set in the Battery discharged signal (three beeps) group, the device will emit three sound signals alarming that the battery is empty.

Battery charging

The device emits a sound signal if the charger is connected to the battery. Duration of the signal is set by the Signal duration on charger connected parameter. The following message will be output to the display in this case:

1734102931997-130.pngThe device emits two signals if the charger is disconnected from the battery. Duration of the signals is set by the Signal duration on charger disconnected parameter. The following message will be output to the display in this case:

1734102958659-972.png

If the battery is charging the following animation will appear on the display:

1734102981350-437.png
1734103175570-572.png
1734103197404-229.png
1734103225567-898.png
1734103241852-723.png

Indication of errors

If there are errors selected by the Errors filters (see Display options group in Configuration), names or codes of errors will be output to the display. In this case a loud sound signal is periodically emitted.

1734103291589-278.png
1734103305252-869.png

If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. It is also available changing pages manually using the button on the device or an external button connected to the P6 header.

Errors shortnames and codes are in the table below.

Error codeError nameDescription
ACKNeed ACKAcknowledge of errors is needed
ADCADC errorWrong values from the ADC
BCBattery coverBattery cover is opened
CCCCH cont. cycleCharge contactor switches too frequency
CCFCH cont. feed.Wrong feedback signal from the charging contactor
CELCell countWrong number of cells
CERCritical errorCritical error
CHTCont. hi. temp.Hight temperature of a contactor
COMCombilift offl.No connection with the Combilift forklift
CROCrown errorCrown forklift error
CSECurrent sensorCurrent sensor is shorted or opened
DCCDCH cont. cycleDischarge contactor switches too frequency
DCFDCH cont. feed.Wrong feedback signal from the discharging contactor
FSEFS errorFilesystem on an SD card is corrupted
HCTHigh CH temp.Battery temperature is too high for charging
HDTHigh DCH temp.Battery temperature is too high for discharging
HHHigh humidityHigh humidity
HYGHYG offlineNo connection with the HYG forklift
LCTLow CH temp.Battery temperature is too low for charging
LDTLow DCH temp.Battery temperature is too low for discharging
LHTLogic hi. temp.Temperature of a BMS Logic board is too high
LOFLogic offlineNo connection with a BMS Logic board
LOGLogic countWrong number of BMS Logic boards
MNTMount errorSD card is not mounted
NTSNo temp. sens.No temperature sensors connected to a BMS Logic
OCOvercurrentHigh current
OVOvervoltageHigh voltage
SETSettings errorChecksum of settings is wrong
SHCShort circuitShort circuit
SHEShunt errorInternal error of the shunt sensor
SHOShunt offlineNo connection with the shunt sensor
SPISpirit offlineNo connection with the Spirit truck
STCStuck contactorContactor is stuck
TSSShorted temp.A temperature sensor connected to a BMS Logic is shorted
UCHUnallowable CHCharging the battery through the discharging circuit
UVUndervoltageLow voltage
WAWaterWater in the battery
WDTWDT resetWatchdog timer reset the BMS