Changes for page 4. Indication

Last modified by Admin on 2025/02/27 15:48

From version 7.3
edited by Admin
on 2025/02/27 15:37
Change comment: There is no comment for this version
To version 7.5
edited by Admin
on 2025/02/27 15:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -59,46 +59,8 @@
59 59  
60 60  If the number of errors is greater than three, a list of errors will be output page by page. Turning pages will be performed automatically every 2 seconds. It is also available changing pages manually using the button on the device or an external button connected to the P6 header.
61 61  
62 -Errors shortnames and codes are in the table below.
62 +Errors short names and abbreviations for BMS Main 2.1, BMS Mini, BMS Mini S and BMS Main 3 are shown [[here>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]].
63 63  
64 -|**Error code**|**Error name**|**Description**
65 -|ACK|Need ACK|Acknowledge of errors is needed
66 -|ADC|ADC error|Wrong values from the ADC
67 -|BC|Battery cover|Battery cover is opened
68 -|CCC|CH cont. cycle|Charge contactor switches too frequency
69 -|CCF|CH cont. feed.|Wrong feedback signal from the charging contactor
70 -|CEL|Cell count|Wrong number of cells
71 -|CER|Critical error|Critical error
72 -|CHT|Cont. hi. temp.|Hight temperature of a contactor
73 -|COM|Combilift offl.|No connection with the Combilift forklift
74 -|CRO|Crown error|Crown forklift error
75 -|CSE|Current sensor|Current sensor is shorted or opened
76 -|DCC|DCH cont. cycle|Discharge contactor switches too frequency
77 -|DCF|DCH cont. feed.|Wrong feedback signal from the discharging contactor
78 -|FSE|FS error|Filesystem on an SD card is corrupted
79 -|HCT|High CH temp.|Battery temperature is too high for charging
80 -|HDT|High DCH temp.|Battery temperature is too high for discharging
81 -|HH|High humidity|High humidity
82 -|HYG|HYG offline|No connection with the HYG forklift
83 -|LCT|Low CH temp.|Battery temperature is too low for charging
84 -|LDT|Low DCH temp.|Battery temperature is too low for discharging
85 -|LHT|Logic hi. temp.|Temperature of a BMS Logic board is too high
86 -|LOF|Logic offline|No connection with a BMS Logic board
87 -|LOG|Logic count|Wrong number of BMS Logic boards
88 -|MNT|Mount error|SD card is not mounted
89 -|NTS|No temp. sens.|No temperature sensors connected to a BMS Logic
90 -|OC|Overcurrent|High current
91 -|OV|Overvoltage|High voltage
92 -|SET|Settings error|Checksum of settings is wrong
93 -|SHC|Short circuit|Short circuit
94 -|SHE|Shunt error|Internal error of the shunt sensor
95 -|SHO|Shunt offline|No connection with the shunt sensor
96 -|SPI|Spirit offline|No connection with the Spirit truck
97 -|STC|Stuck contactor|Contactor is stuck
98 -|TSS|Shorted temp.|A temperature sensor connected to a BMS Logic is shorted
99 -|UCH|Unallowable CH|Charging the battery through the discharging circuit
100 -|UV|Undervoltage|Low voltage
101 -|WA|Water|Water in the battery
102 -|WDT|WDT reset|Watchdog timer reset the BMS
64 +Errors short names and abbreviations for BMS Main X and BMS Main 3X are shown [[here>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HErrors"]].
103 103  
104 104