2. Installation and connection

Version 3.1 by Admin on 2024/12/13 15:05

Installation and connection

Installation

1734102043915-364.png

ParameterValue
Overall dimensions (length × width × height), mm140 × 37 × 23
Mounting dimensions (length × width), mm134 × 31
Mounting holesM3
Header typesMolex series Micro-Fit

Connection

The BMS Display has three headers for connecting the BMS (P3, P4 и P5), a header for an external button (P6) and a switch which connects a terminal resistor to the CAN bus (SWD1).

P3, P4 and P5 – headers for communication with BMS

1734102177551-232.png

PinNameDescription
1CANHCAN H line for communication with the BMS controller
2CANLCAN L line for communication with the BMS controller
3+5VSupply voltage 5 V
4GNDGround

P6 – header for external button1734102225110-114.png

PinNameDescription
1BTN1Button line (dry contact)
2BTN2Button line (dry contact)

SWD1 - CAN terminal resistor switch

To connect the terminal resistor between the CANH and CANL lines, switch the SWD1 to the ON position.