Here is the list of available input signals of BMS Main 3.
| Name | Abbr. | Description | Compability | CANopen SDO | Modbus | ||
|---|---|---|---|---|---|---|---|
| Mini S / Mini | Main 2.1 | Main 3 | |||||
| Battery cover | a signal from the battery cover; | Yes | Yes | Yes | |||
| Charger connected | a signal indicating that charger is connected; | Yes | Yes | Yes | |||
| Power up/down request | a request to power down the device; | Yes | Yes | Yes | |||
| Inhibit charging | a command to open the charging contactor; | Yes | Yes | Yes | |||
| Inhibit discharging | a command to open the discharging contactor; | Yes | Yes | Yes | |||
| CH contactor feedback | a signal from charging contactor feedback loop; | Yes | Yes | Yes | |||
| DCH contactor feedback | a signal from discharging contactor feedback loop; | Yes | Yes | Yes | |||
| Insulation status | a signal from an insulation monitoring device; | Yes | Yes | Yes | |||
| Charge request | a request to close the charging contactor; | Yes | Yes | Yes | |||
| Discharge request | a request to close the discharging contactor; | Yes | Yes | Yes | |||
| PCH contactor feedback | a signal from precharging contactor feedback loop; | Yes | Yes | Yes | |||
| CH/DCH contactor feedback | a signal from charging/discharging contactor feedback loop; | Yes | Yes | Yes | |||
| Main contactor feedback | a signal from main contactor feedback loop; | Yes | Yes | Yes | |||
| Interlock | a signal from interlock loop; | Yes | Yes | Yes | |||
| Fuse 1, Fuse 2, Fuse 3 | signals from fuses; | Yes | Yes | Yes | |||
| Circuit breaker status | status of protection disconnector; | Yes | Yes | Yes | |||
| Balancing request | a request to balance the cells; | Yes | Yes | Yes | |||
| Close Main contactor | a request to close the main contactor; | Yes | Yes | Yes | |||
| Close External 1 | a request to close the External 1 discrete output (if assigned). | Yes | Yes | Yes | |||
List of internal states
Here is the list of available internal states of BMS Main 3.
| Name | Abbr. | Description | Compability | CANopen SDO | Modbus | ||
|---|---|---|---|---|---|---|---|
| Mini S / Mini | Main 2.1 | Main 3 | |||||
| Low SOC | a signal corresponding the low SOC of the battery; | Yes | Yes | Yes | |||
| High charging current | charging current is high; | Yes | Yes | Yes | |||
| Main contactor | state of the main contactor; | Yes | Yes | Yes | |||
| Charging | state of the charging contactor; | Yes | Yes | Yes | |||
| Allow charging | a signal for a charger to start charging; | Yes | Yes | Yes | |||
| Charging current present | the presence of the charging current; | Yes | Yes | Yes | |||
| Precharging | state of the precharging contactor; | Yes | Yes | Yes | |||
| Discharging | state of the discharging contactor; | Yes | Yes | Yes | |||
| Discharging current present | the presence of the discharging current; | Yes | Yes | Yes | |||
| Discharging (AUX) | state of the auxiliary discharging contactor; | Yes | Yes | Yes | |||
| Power down ACK | an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; | Yes | Yes | Yes | |||
| Charging/discharging | state of the charging/discharging contactor; | Yes | Yes | Yes | |||
| Heater | a command to turn on a heater; | Yes | Yes | Yes | |||
| Cooler | a command to turn on a cooler; | Yes | Yes | Yes | |||
| Balancing 1 | balancing the first series of cells; | Yes | Yes | Yes | |||
| Balancing 2 | balancing the second series of cells; | Yes | Yes | Yes | |||
| Ready to charge | the battery is ready to be charged; | Yes | Yes | Yes | |||
| Ready to discharge | the battery is ready to be discharged; | Yes | Yes | Yes | |||
| Power up | an indication of BMS power status; | Yes | Yes | Yes | |||
| General error | state of the configurable (general) error; | Yes | Yes | Yes | |||
| External 1 | a signal that activates by the remote request. | Yes | Yes | Yes | |||
List of errors
Here is the list of error of BMS Main 3.
| Name | Abbr. | Description | Is a Critical error? | Compability | CANopen SDO | Modbus | ||
| Mini S / Mini | Main 2.1 | Main 3 | ||||||
|---|---|---|---|---|---|---|---|---|
| Overcurrent | OC | Yes | Yes | Yes | ||||
| Undervoltage | UV | Yes | Yes | Yes | ||||
| Overvoltage | OV | Yes | Yes | Yes | ||||
| Low temperature (DCH) | LDT | temperature is too low for discharging; | Yes | Yes | Yes | |||
| High temperature (DCH) | HDT | temperature is too high for discharging; | Yes | Yes | Yes | |||
| Battery cover error | BC | battery cover is open; | • | Yes | Yes | Yes | ||
| High humidity | HH | humidity of the battery is increased; | Yes | Yes | Yes | |||
| Water | WA | there is water in the battery enclosure; | • | Yes | Yes | Yes | ||
| High Logic temperature | LHT | at least one of the Logic devices is overheated; | Yes | Yes | Yes | |||
| Logic offline | LOF | at least one of the Logic devices is offline; | • | Yes | Yes | Yes | ||
| Critical error | CER | Yes | Yes | Yes | ||||
| Crown error | CRO | connection with a Crown forklift is lost; | Yes | Yes | Yes | |||
| Cell count error | CEL | number of cells does not match the specified value; | • | Yes | Yes | Yes | ||
| HYG offline | HYG | connection with a HYG forklift is lost; | Yes | Yes | Yes | |||
| Need acknowledge | ACK | there is an unacknowledged error in Error journal; | Yes | Yes | Yes | |||
| Combilift offline | COM | connection with a Combilift forklift is lost; | Yes | Yes | Yes | |||
| Short circuit | SHC | Yes | Yes | Yes | ||||
| High contactor temperature | CHT | Yes | Yes | Yes | ||||
| Logic count error | LOG | |||||||
| ADC error | ADC | current cannot be measured; | • | Yes | Yes | Yes | ||
| Current sensor error | CSE | error in the current sensor circuit; | • | Yes | Yes | Yes | ||
| CH contactor cycles error | CCC | switching frequency of the charging contactor is too high; | Yes | Yes | Yes | |||
| DCH contactor cycles error | DCC | switching frequency of the discharging contactor is too high; | Yes | Yes | Yes | |||
| Shunt offline | SHO | connection with the shunt current sensor is lost; | • | Yes | Yes | Yes | ||
| Shunt error | SHE | internal error of the shunt current sensor; | • | Yes | Yes | Yes | ||
| Settings error | SET | |||||||
| WDT reset | WDT | watchdog timer reset the device; | • | Yes | Yes | Yes | ||
| No temperature sensors | NTS | the device has no temperature sensors connected; | • | Yes | Yes | Yes | ||
| Temperature sensor is shorted | TSS | some temperature sensors are shorted; | • | Yes | Yes | Yes | ||
| Spirit offline | SPI | connection with a Spirit forklift is lost; | Yes | Yes | Yes | |||
| Mount error | MNT | Yes | Yes | Yes | ||||
| FS error | FSE | Yes | Yes | Yes | ||||
| Low temperature (CH) | LCT | temperature is too low for charging; | Yes | Yes | Yes | |||
| High temperature (CH) | HCT | temperature is too high for charging; | Yes | Yes | Yes | |||
| Unallowable charging | UCH | charging the battery through the discharging contactor; | Yes | Yes | Yes | |||
| Stuck contactor | STC | • | Yes | Yes | Yes | |||
| CH contactor feedback error | CCF | the control signals for the charging contactor and the contactor feedback differ; | • | Yes | ||||
| DCH contactor feedback error | DCF | the control signals for the discharging contactor and the contactor feedback differ; | • | Yes | ||||
| Insulation fault; | INF | • | Yes | Yes | Yes | |||
| PCH contactor feedback error | PCF | the control signals for the precharging contactor and the contactor feedback differ; | • | Yes | ||||
| CH/DCH contactor feedback error | CDF | the control signals for the charging/discharging contactor and the contactor feedback differ; | • | Yes | ||||
| Main contactor feedback error | MCF | the control signals for the main contactor and the contactor feedback differ; | • | Yes | ||||
| Contactor feedback error | CFE | Failure of one of the contactors feedback signal. Which contactor is failed can be | Yes | Yes | ||||
| General error | GE | Yes | Yes | Yes | ||||
| High voltage fault | HVF | failure of high voltage measuring circuits; | • | Yes | ||||
| Power switch error | PSE | short circuit in contactor coil control circuit or power switch overheating; | • | Yes | ||||
| HVIL error | HE | breakage of high-voltage interlock current loop; | • | Yes | ||||
| Precharge error | PE | capacitive load pre-charge process did not end during the estimated time; | Yes | Yes | Yes | |||
| Power fault | PF | external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices; | • | Yes | ||||
| Current limit error | CLE | charging or discharging current is more than limit calculated by Charge map or Discharge map. | Yes | Yes | ||||