3.1 General information

Version 1.30 by Admin on 2025/01/29 16:49

Configuration

General information

List of input signals

Here is the list of available input signals of BMS Main 3.

NameDescriptionWhere is usedSettable via
Discrete inputCANModbus
Battery cover  a signal from the battery cover;Battery cover protection  
Charger connected  a signal indicating that charger is connected;Charge controller, Discharge controller• (if corresponding External equipment is online) 
Power up/down request  a request to power down the device;Power down controller  
Inhibit charging  a command to open the charging contactor;   
Inhibit discharging  a command to open the discharging contactor;   
CH contactor feedback  a signal from charging contactor feedback loop;Contactor feedback protection  
DCH contactor feedback  a signal from discharging contactor feedback loop;Contactor feedback protection  
Insulation status  a signal from an insulation monitoring device;Insulation protection  
Charge request  a request to close the charging contactor;Charge controller• (by request) 
Discharge request  a request to close the discharging contactor;Discharge controller• (by request) 
PCH contactor feedback  a signal from precharging contactor feedback loop;Contactor feedback protection  
CH/DCH contactor feedback  a signal from charging/discharging contactor feedback loop;Contactor feedback protection  
Main contactor feedback  a signal from main contactor feedback loop;Contactor feedback protection  
Interlock  a signal from interlock loop;Interlock protection  
Fuse 1, Fuse 2, Fuse 3  signals from fuses;   
Circuit breaker status  status of protection disconnector;   
Balancing request  a request to balance the cells;Cell balance controller 
Close Main contactor  a request to close the main contactor;Main contactor controller• (by request) 
Close External 1  a request to close the External 1 discrete output (if assigned).   

List of internal states

Here is the list of available internal states of BMS Main 3.

NameDescriptionWhere is usedShared via
Discrete outputCANModbus
Low SOC  a signal corresponding the low SOC of the battery;Low SOC controller  
High charging current  charging current is high;Charge controller, Discharge controller• (if corresponding External equipment is online) 
Main contactor  state of the main contactor;Power down  
Charging  state of the charging contactor;   
Allow charging  a signal for a charger to start charging;   
Charging current present  the presence of the charging current;Contactor feedback protection  
Precharging  state of the precharging contactor;Contactor feedback protection  
Discharging  state of the discharging contactor;Insulation protection  
Discharging current present  the presence of the discharging current;Charge controller• (by request) 
Discharging (AUX)  state of the auxiliary discharging contactor;Discharge controller• (by request) 
Power down ACK  an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;Contactor feedback protection  
Charging/discharging - state of the charging/discharging contactor; Contactor feedback protection  
Heater  a command to turn on a heater;Contactor feedback protection  
Cooler  a command to turn on a cooler;Interlock protection  
Balancing 1  balancing the first series of cells;   
Balancing 2  balancing the second series of cells;   
Ready to charge  the battery is ready to be charged;Cell balance 
Ready to discharge  the battery is ready to be discharged;Main contactor• (by request) 
Power up  an indication of BMS power status;   
General error  state of the configurable (general) error;    
External 1  a signal that activates by the remote request.