3.1 General information

Version 1.1 by Admin on 2025/01/29 16:27

Configuration

General information

Connection

Configuring can be done using the ElectricDeviceMonitor above the 1.18.0 (available by the link) via

  • USB;
  • CAN bus (Systec, PEAK, Marathon and USB-CAN adapters are supported);
  • TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main 3).

After connecting device to the PC, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window:

1735233230234-960.png

Choose the connection type and set up connection settings:

  • Serial port (USB): choose the corresponding COM port;

1733320484262-545.png1733320484267-118.png

  • Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN: select the device in device list, specify the CAN speed and BMS device address:

1735233434987-983.png

  • TCP connection: set up the device IP address.

1735234302538-838.png

When connected, the device asks for an access password. For the "User" account, the default password is "user" (without quotes).

1735053821120-339.png

After successful authentication, the device will send settings and state profiles, which will be displayed as two tabs: "Settings" and "State":

1735053858994-348.png

The monitor window is divided into three areas. The upper area displays controls for starting and stopping communication with the device, information about the device (its name, hardware and firmware versions, time on the device clock), and controls for performing actions with the device (change password, restart, reset, etc.).

The central area displays the parameters and state variables of the device. The tabs in this area are divided into three columns. The first column displays parameter groups in a tree form, the second column displays records for the selected group, and the third displays the detailed description of the record.

The lower area shows the history of device activity.