Changes for page 2. Strings controllers: signals and errors
Last modified by Admin on 2025/02/21 14:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -91,31 +91,29 @@ 91 91 |(% style="width:196px" %)CH contactor cycles error |(% style="width:58px" %)CCC|(% style="width:443px" %) switching frequency of the charging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 92 |(% style="width:196px" %)DCH contactor cycles error |(% style="width:58px" %)DCC|(% style="width:443px" %) switching frequency of the discharging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 93 93 |(% style="width:196px" %)Shunt offline |(% style="width:58px" %)SHO|(% style="width:443px" %) connection with the shunt current sensor is lost;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 94 -|(% style="width:196px" %)Shunt error |(% style="width:58px" %)SHE|(% style="width:443px" %) internal error of the shunt current sensor;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 95 -|(% style="width:196px" %)Settings error|(% style="width:58px" %)SET|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 96 -|(% style="width:196px" %)WDT reset |(% style="width:58px" %)WDT|(% style="width:443px" %) watchdog timer reset the device;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 97 -|(% style="width:196px" %)No temperature sensors |(% style="width:58px" %)NTS|(% style="width:443px" %) the device has no temperature sensors connected;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 98 -|(% style="width:196px" %)Temperature sensor is shorted |(% style="width:58px" %)TSS|(% style="width:443px" %) some temperature sensors are shorted;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 -|(% style="width:196px" %)Spirit offline |(% style="width:58px" %)SPI|(% style="width:443px" %) connection with a Spirit forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 -|(% style="width:196px" %)Mount error|(% style="width:58px" %)MNT|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 101 -|(% style="width:196px" %)FS error|(% style="width:58px" %)FSE|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 102 -|(% style="width:196px" %)Low temperature (CH) |(% style="width:58px" %)LCT|(% style="width:443px" %) temperature is too low for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 -|(% style="width:196px" %)High temperature (CH) |(% style="width:58px" %)HCT|(% style="width:443px" %) temperature is too high for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 104 -|(% style="width:196px" %)Unallowable charging |(% style="width:58px" %)UCH|(% style="width:443px" %) charging the battery through the discharging contactor;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 105 -|(% style="width:196px" %)Stuck contactor|(% style="width:58px" %)STC|(% style="width:443px" %) |(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 106 -|(% style="width:196px" %)CH contactor feedback error |(% style="width:58px" %)CCF|(% style="width:443px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 107 -|(% style="width:196px" %)DCH contactor feedback error |(% style="width:58px" %)DCF|(% style="width:443px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 108 -|(% style="width:196px" %)Insulation fault;|(% style="width:58px" %)INF|(% style="width:443px" %) |(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 -|(% style="width:196px" %)PCH contactor feedback error |(% style="width:58px" %)PCF|(% style="width:443px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 110 -|(% style="width:196px" %)CH/DCH contactor feedback error |(% style="width:58px" %)CDF|(% style="width:443px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 111 -|(% style="width:196px" %)Main contactor feedback error |(% style="width:58px" %)MCF|(% style="width:443px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 112 -|(% style="width:196px" %)Contactor feedback error|(% style="width:58px" %)CFE|(% style="width:443px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 113 -|(% style="width:196px" %)General error|(% style="width:58px" %)GE|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 114 -|(% style="width:196px" %)High voltage fault |(% style="width:58px" %)HVF|(% style="width:443px" %) failure of high voltage measuring circuits;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 115 -|(% style="width:196px" %)Power switch error |(% style="width:58px" %)PSE|(% style="width:443px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 116 -|(% style="width:196px" %)HVIL error |(% style="width:58px" %)HE|(% style="width:443px" %) breakage of high-voltage interlock current loop;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 117 -|(% style="width:196px" %)Precharge error |(% style="width:58px" %)PE|(% style="width:443px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 118 -|(% style="width:196px" %)Power fault |(% style="width:58px" %)PF|(% style="width:443px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 119 -|(% style="width:196px" %)Current limit error |(% style="width:58px" %)CLE|(% style="width:443px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 94 +|(% style="width:196px" %)Shunt error |(% style="width:58px" %) |(% style="width:443px" %) internal error of the shunt current sensor;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 95 +|(% style="width:196px" %)WDT reset |(% style="width:58px" %) |(% style="width:443px" %) watchdog timer reset the device;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 96 +|(% style="width:196px" %)No temperature sensors |(% style="width:58px" %) |(% style="width:443px" %) the device has no temperature sensors connected;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 97 +|(% style="width:196px" %)Temperature sensor is shorted |(% style="width:58px" %) |(% style="width:443px" %) some temperature sensors are shorted;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 98 +|(% style="width:196px" %)Spirit offline |(% style="width:58px" %) |(% style="width:443px" %) connection with a Spirit forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 +|(% style="width:196px" %)Mount error|(% style="width:58px" %) |(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 +|(% style="width:196px" %)FS error|(% style="width:58px" %) |(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 101 +|(% style="width:196px" %)Low temperature (CH) |(% style="width:58px" %) |(% style="width:443px" %) temperature is too low for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 102 +|(% style="width:196px" %)High temperature (CH) |(% style="width:58px" %) |(% style="width:443px" %) temperature is too high for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 +|(% style="width:196px" %)Unallowable charging |(% style="width:58px" %) |(% style="width:443px" %) charging the battery through the discharging contactor;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 104 +|(% style="width:196px" %)Stuck contactor|(% style="width:58px" %) |(% style="width:443px" %) |(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 105 +|(% style="width:196px" %)CH contactor feedback error |(% style="width:58px" %) |(% style="width:443px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 106 +|(% style="width:196px" %)DCH contactor feedback error |(% style="width:58px" %) |(% style="width:443px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 107 +|(% style="width:196px" %)Insulation fault;|(% style="width:58px" %) |(% style="width:443px" %) |(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 108 +|(% style="width:196px" %)PCH contactor feedback error |(% style="width:58px" %) |(% style="width:443px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 +|(% style="width:196px" %)CH/DCH contactor feedback error |(% style="width:58px" %) |(% style="width:443px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 110 +|(% style="width:196px" %)Main contactor feedback error |(% style="width:58px" %) |(% style="width:443px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 +|(% style="width:196px" %)General error|(% style="width:58px" %) |(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 112 +|(% style="width:196px" %)High voltage fault |(% style="width:58px" %) |(% style="width:443px" %) failure of high voltage measuring circuits;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 113 +|(% style="width:196px" %)Power switch error |(% style="width:58px" %) |(% style="width:443px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 114 +|(% style="width:196px" %)HVIL error |(% style="width:58px" %) |(% style="width:443px" %) breakage of high-voltage interlock current loop;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 115 +|(% style="width:196px" %)Precharge error |(% style="width:58px" %) |(% style="width:443px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 116 +|(% style="width:196px" %)Power fault |(% style="width:58px" %) |(% style="width:443px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 117 +|(% style="width:196px" %)Current limit error |(% style="width:58px" %) |(% style="width:443px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 120 120 121 121