| Name | Abbr. | Description | Compability with discrete inputs | CANopen SDO | Modbus | 
|---|
| Mini S / Mini | Main 2.1 | Main 3 | 
|---|
| Balancing request  | BR | a request to balance the cells; | Yes | Yes | Yes |   |   | 
| Battery cover  | CVR | a signal from the battery cover; | Yes | Yes | Yes |   |   | 
| CH contactor feedback  | CCF | a signal from charging contactor feedback loop; | Yes* | Yes | Yes |   |   | 
| CH/DCH contactor feedback  | CDF | a signal from charging/discharging contactor feedback loop; | Yes* | Yes | Yes |   |   | 
| Charge request  | CRE | a request to close the charging contactor; | Yes | Yes | Yes |   |   | 
| Charger connected  | CON | a signal indicating that charger is connected; | Yes | Yes | Yes |   |   | 
| Circuit breaker status  | CBS | status of protection disconnector; | Yes | Yes | Yes |   |   | 
| Close External 1  | CE1 | a request to close the External 1 discrete output (if assigned). | Yes | Yes | Yes |   |   | 
| Close Main contactor  | CMC | a request to close the main contactor; | Yes | Yes | Yes |   |   | 
| DCH contactor feedback  | DCF | a signal from discharging contactor feedback loop; | Yes* | Yes | Yes |   |   | 
| Discharge request  | DRE | a request to close the discharging contactor; | Yes | Yes | Yes |   |   | 
| Fuse 1 | F1 | signal from fuse 1; | Yes | Yes | Yes |   |   | 
| Fuse 2 | F2 | signal from fuse 2; | Yes | Yes | Yes |   |   | 
| Fuse 3  | F3 | signal from fuse 3; | Yes | Yes | Yes |   |   | 
| Inhibit charging  | ICH | a command to open the charging contactor; | Yes | Yes | Yes |   |   | 
| Inhibit discharging  | IDC | a command to open the discharging contactor; | Yes | Yes | Yes |   |   | 
| Insulation status  | INS | a signal from an insulation monitoring device; | Yes | Yes | Yes |   |   | 
| Interlock  |   | a signal from interlock loop; | Yes | Yes | Yes |   |   | 
| Main contactor feedback  | MCF | a signal from main contactor feedback loop; | Yes* | Yes | Yes |   |   | 
| PCH contactor feedback  | PCF | a signal from precharging contactor feedback loop; | Yes* | Yes | Yes |   |   | 
| Power up/down request  | PDN | a request to power down the device; | Yes | Yes | Yes |   |   | 
| Precharge request | PRE | a request to close the precharging contactor | Yes | Yes |   |   |   | 
| Name | Abbr. | Description | Compability | CANopen SDO | Modbus | 
|---|
| Mini S / Mini | Main 2.1 | Main 3 | 
|---|
| Allow charging  | ACH | a signal for a charger to start charging; | Yes | Yes | Yes |   |   | 
| Balancing 1  | BA1 | balancing the first series of cells; |   | Yes | Yes |   |   | 
| Balancing 2  | BA2 | balancing the second series of cells; |   | Yes | Yes |   |   | 
| Cell analysis | CEA |   | Yes | Yes | Yes |   |   | 
| Charging current present  | CCP | the presence of the charging current; | Yes | Yes | Yes |   |   | 
| Charging  | CH | state of the charging contactor; | Yes | Yes | Yes |   |   | 
| Charging/discharging | C/D | state of the charging/discharging contactor; | Yes | Yes | Yes |   |   | 
| Cooler  | COO | a command to turn on a cooler; | Yes | Yes | Yes |   |   | 
| Crown EWS | EWS |   | Yes | Yes | Yes |   |   | 
| Discharging (AUX)  | AUX | state of the auxiliary discharging contactor; | Yes | Yes | Yes |   |   | 
| Discharging current present  | DCP | the presence of the discharging current; | Yes | Yes | Yes |   |   | 
| Discharging  | DCH | state of the discharging contactor; | Yes | Yes | Yes |   |   | 
| External 1  | EX1 | a signal that activates by the remote request. |   | Yes | Yes |   |   | 
| Heater  | HEA | a command to turn on a heater; | Yes | Yes | Yes |   |   | 
| Heater (AUX) | HA |   |   | Yes | Yes |   |   | 
| High charging current  | HCC | charging current is high; | Yes | Yes | Yes |   |   | 
| Init | INI |   | Yes | Yes | Yes |   |   | 
| Low SOC  | LOS | a signal corresponding the low SOC of the battery; | Yes | Yes | Yes |   |   | 
| Main contactor  | MCO | state of the main contactor; | Yes | Yes | Yes |   |   | 
| Power down ACK  | PDA | an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; | Yes | Yes | Yes |   |   | 
| Power up  | PUP | an indication of BMS power status; | Yes | Yes | Yes |   |   | 
| Precharging  | PRE | state of the precharging contactor; | Yes | Yes | Yes |   |   | 
| Ready to charge  | RTC | the battery is ready to be charged; | Yes | Yes | Yes |   |   | 
| Ready to discharge  | RTD | the battery is ready to be discharged; | Yes | Yes | Yes |   |   | 
| Service reset | SR |   | Yes |   | Yes |   |   | 
| Shutdown request (Combilift) | CSH |   | Yes | Yes | Yes |   |   | 
| Shutdown request (HYG/Spirit) | HSH |   | Yes | Yes | Yes |   |   | 
| Voltage too high for charging | ENV |   | Yes | Yes | Yes |   |   | 
| Name  | Abbr. | Description | Is a Critical error? | Compability | CANopen SDO | Modbus | 
| Mini S / Mini | Main 2.1 | Main 3 | 
|---|
| ADC error  | ADC | current cannot be measured; | • | Yes | Yes | Yes |   |   | 
| Battery cover error  | BC | battery cover is open; | • | Yes | Yes | Yes |   |   | 
| Cell count error  | CEL | number of cells does not match the specified value; | • | Yes | Yes | Yes |   |   | 
| CH contactor cycles error  | CCC | switching frequency of the charging contactor is too high; |   | Yes | Yes | Yes |   |   | 
| CH contactor feedback error  | CCF | the control signals for the charging contactor and the contactor feedback differ; | • |   | Yes |   |   |   | 
| CH/DCH contactor feedback error  | CDF | the control signals for the charging/discharging contactor and the contactor feedback differ; | • |   | Yes |   |   |   | 
| Combilift offline  | COM | connection with a Combilift forklift is lost; |   | Yes | Yes | Yes |   |   | 
| Contactor feedback error | CFE | Failure of one of the contactors feedback signal. Which contactor is failed can be  |   | Yes |   | Yes |   |   | 
| Critical error | CER |   |   | Yes | Yes | Yes |   |   | 
| Crown error  | CRO | connection with a Crown forklift is lost; |   | Yes | Yes | Yes |   |   | 
| Current limit error  | CLE | charging or discharging current is more than limit calculated by Charge map or Discharge map. |   | Yes |   | Yes |   |   | 
| Current sensor error  | CSE | error in the current sensor circuit; | • | Yes | Yes | Yes |   |   | 
| DCH contactor cycles error  | DCC | switching frequency of the discharging contactor is too high; |   | Yes | Yes | Yes |   |   | 
| DCH contactor feedback error  | DCF | the control signals for the discharging contactor and the contactor feedback differ; | • |   | Yes |   |   |   | 
| FS error | FSE |   |   | Yes | Yes | Yes |   |   | 
| General error | GE |   |   | Yes | Yes | Yes |   |   | 
| High contactor temperature | CHT |   |   | Yes | Yes | Yes |   |   | 
| High humidity  | HH | humidity of the battery is increased; |   | Yes | Yes | Yes |   |   | 
| High Logic temperature  | LHT | at least one of the Logic devices is overheated; |   | Yes | Yes | Yes |   |   | 
| High temperature (CH)  | HCT | temperature is too high for charging; |   | Yes | Yes | Yes |   |   | 
| High temperature (DCH)  | HDT | temperature is too high for discharging; |   | Yes | Yes | Yes |   |   | 
| High voltage fault  | HVF | failure of high voltage measuring circuits; | • |   |   | Yes |   |   | 
| HVIL error  | HE | breakage of high-voltage interlock current loop; | • |   |   | Yes |   |   | 
| HYG offline  | HYG | connection with a HYG forklift is lost; |   | Yes | Yes | Yes |   |   | 
| Insulation fault; | INF |   | • | Yes | Yes | Yes |   |   | 
| Logic count error | LOG |   |   |   |   |   |   |   | 
| Logic offline  | LOF | at least one of the Logic devices is offline; | • | Yes | Yes | Yes |   |   | 
| Low temperature (CH)  | LCT | temperature is too low for charging; |   | Yes | Yes | Yes |   |   | 
| Low temperature (DCH)  | LDT | temperature is too low for discharging; |   | Yes | Yes | Yes |   |   | 
| Main contactor feedback error  | MCF | the control signals for the main contactor and the contactor feedback differ; | • |   | Yes |   |   |   | 
| Mount error | MNT |   |   | Yes | Yes | Yes |   |   | 
| Need acknowledge  | ACK | there is an unacknowledged error in Error journal; |   | Yes | Yes | Yes |   |   | 
| No temperature sensors  | NTS | the device has no temperature sensors connected; | • | Yes | Yes | Yes |   |   | 
| Overcurrent | OC |   |   | Yes | Yes | Yes |   |   | 
| Overvoltage | OV |   |   | Yes | Yes | Yes |   |   | 
| PCH contactor feedback error  | PCF | the control signals for the precharging contactor and the contactor feedback differ; | • |   | Yes |   |   |   | 
| Power fault  | PF | external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices; | • |   |   | Yes |   |   | 
| Power switch error  | PSE | short circuit in contactor coil control circuit or power switch overheating; | • |   |   | Yes |   |   | 
| Precharge error  | PE | capacitive load pre-charge process did not end during the estimated time; |   | Yes | Yes | Yes |   |   | 
| Settings error | SET |   |   |   |   |   |   |   | 
| Short circuit | SHC |   |   | Yes | Yes | Yes |   |   | 
| Shunt error  | SHE | internal error of the shunt current sensor; | • | Yes | Yes | Yes |   |   | 
| Shunt offline  | SHO | connection with the shunt current sensor is lost; | • | Yes | Yes | Yes |   |   | 
| Spirit offline  | SPI | connection with a Spirit forklift is lost; |   | Yes | Yes | Yes |   |   | 
| Stuck contactor | STC |   | • | Yes | Yes | Yes |   |   | 
| Temperature sensor is shorted  | TSS | some temperature sensors are shorted; | • | Yes | Yes | Yes |   |   | 
| Unallowable charging  | UCH | charging the battery through the discharging contactor; |   | Yes | Yes | Yes |   |   | 
| Undervoltage | UV |   |   | Yes | Yes | Yes |   |   | 
| Water  | WA | there is water in the battery enclosure; | • | Yes | Yes | Yes |   |   | 
| WDT reset  | WDT | watchdog timer reset the device; | • | Yes | Yes | Yes |   |   |