Configuration
General information
List of input signals
Here is the list of available input signals of BMS Main 3.
Name | Abbr. | Description | Compability | CANopen SDO | Modbus | ||
---|---|---|---|---|---|---|---|
Mini S / Mini | Main 2.1 | Main 3 | |||||
Battery cover | a signal from the battery cover; | Yes | Yes | Yes | |||
Charger connected | a signal indicating that charger is connected; | Yes | Yes | Yes | |||
Power up/down request | a request to power down the device; | Yes | Yes | Yes | |||
Inhibit charging | a command to open the charging contactor; | Yes | Yes | Yes | |||
Inhibit discharging | a command to open the discharging contactor; | Yes | Yes | Yes | |||
CH contactor feedback | a signal from charging contactor feedback loop; | Yes | Yes | Yes | |||
DCH contactor feedback | a signal from discharging contactor feedback loop; | Yes | Yes | Yes | |||
Insulation status | a signal from an insulation monitoring device; | Yes | Yes | Yes | |||
Charge request | a request to close the charging contactor; | Yes | Yes | Yes | |||
Discharge request | a request to close the discharging contactor; | Yes | Yes | Yes | |||
PCH contactor feedback | a signal from precharging contactor feedback loop; | Yes | Yes | Yes | |||
CH/DCH contactor feedback | a signal from charging/discharging contactor feedback loop; | Yes | Yes | Yes | |||
Main contactor feedback | a signal from main contactor feedback loop; | Yes | Yes | Yes | |||
Interlock | a signal from interlock loop; | Yes | Yes | Yes | |||
Fuse 1, Fuse 2, Fuse 3 | signals from fuses; | Yes | Yes | Yes | |||
Circuit breaker status | status of protection disconnector; | Yes | Yes | Yes | |||
Balancing request | a request to balance the cells; | Yes | Yes | Yes | |||
Close Main contactor | a request to close the main contactor; | Yes | Yes | Yes | |||
Close External 1 | a request to close the External 1 discrete output (if assigned). | Yes | Yes | Yes |
List of internal states
Here is the list of available internal states of BMS Main 3.
Name | Abbr. | Description | Compability | CANopen SDO | Modbus | ||
---|---|---|---|---|---|---|---|
Mini S / Mini | Main 2.1 | Main 3 | |||||
Low SOC | a signal corresponding the low SOC of the battery; | Yes | Yes | Yes | |||
High charging current | charging current is high; | Yes | Yes | Yes | |||
Main contactor | state of the main contactor; | Yes | Yes | Yes | |||
Charging | state of the charging contactor; | Yes | Yes | Yes | |||
Allow charging | a signal for a charger to start charging; | Yes | Yes | Yes | |||
Charging current present | the presence of the charging current; | Yes | Yes | Yes | |||
Precharging | state of the precharging contactor; | Yes | Yes | Yes | |||
Discharging | state of the discharging contactor; | Yes | Yes | Yes | |||
Discharging current present | the presence of the discharging current; | Yes | Yes | Yes | |||
Discharging (AUX) | state of the auxiliary discharging contactor; | Yes | Yes | Yes | |||
Power down ACK | an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; | Yes | Yes | Yes | |||
Charging/discharging | state of the charging/discharging contactor; | Yes | Yes | Yes | |||
Heater | a command to turn on a heater; | Yes | Yes | Yes | |||
Cooler | a command to turn on a cooler; | Yes | Yes | Yes | |||
Balancing 1 | balancing the first series of cells; | Yes | Yes | Yes | |||
Balancing 2 | balancing the second series of cells; | Yes | Yes | Yes | |||
Ready to charge | the battery is ready to be charged; | Yes | Yes | Yes | |||
Ready to discharge | the battery is ready to be discharged; | Yes | Yes | Yes | |||
Power up | an indication of BMS power status; | Yes | Yes | Yes | |||
General error | state of the configurable (general) error; | Yes | Yes | Yes | |||
External 1 | a signal that activates by the remote request. | Yes | Yes | Yes |
List of errors
Here is the list of error of BMS Main 3.
Name | Abbr. | Description | Compability | Is a Critical error? | CANopen SDO | Modbus | ||
Mini S / Mini | Main 2.1 | Main 3 | ||||||
---|---|---|---|---|---|---|---|---|
Overcurrent | OC | |||||||
Undervoltage | UV | |||||||
Overvoltage | OV | |||||||
Low temperature (DCH) | LDT | temperature is too low for discharging; | ||||||
High temperature (DCH) | HDT | temperature is too high for discharging; | ||||||
Battery cover error | BC | battery cover is open; | Yes | |||||
High humidity | HH | humidity of the battery is increased; | ||||||
Water | WA | there is water in the battery enclosure; | Yes | |||||
High Logic temperature | LHT | at least one of the Logic devices is overheated; | ||||||
Logic offline | LOF | at least one of the Logic devices is offline; | Yes | |||||
Critical error | CRE | |||||||
Crown error | CRO | connection with a Crown forklift is lost; | ||||||
Cell count error | CEL | number of cells does not match the specified value; | Yes | |||||
HYG offline | HYG | connection with a HYG forklift is lost; | ||||||
Need acknowledge | there is an unacknowledged error in Error journal; | |||||||
Combilift offline | connection with a Combilift forklift is lost; | |||||||
Short circuit | ||||||||
High contactor temperature | ||||||||
ADC error | current cannot be measured; | Yes | ||||||
Current sensor error | error in the current sensor circuit; | Yes | ||||||
CH contactor cycles error | switching frequency of the charging contactor is too high; | |||||||
DCH contactor cycles error | switching frequency of the discharging contactor is too high; | |||||||
Shunt offline | connection with the shunt current sensor is lost; | Yes | ||||||
Shunt error | internal error of the shunt current sensor; | Yes | ||||||
WDT reset | watchdog timer reset the device; | Yes | ||||||
No temperature sensors | the device has no temperature sensors connected; | Yes | ||||||
Temperature sensor is shorted | some temperature sensors are shorted; | Yes | ||||||
Spirit offline | connection with a Spirit forklift is lost; | |||||||
Low temperature (CH) | temperature is too low for charging; | |||||||
High temperature (CH) | temperature is too high for charging; | |||||||
Unallowable charging | charging the battery through the discharging contactor; | |||||||
Stuck contactor | Yes | |||||||
CH contactor feedback error | the control signals for the charging contactor and the contactor feedback differ; | Yes | ||||||
DCH contactor feedback error | the control signals for the discharging contactor and the contactor feedback differ; | Yes | ||||||
Insulation fault; | Yes | |||||||
PCH contactor feedback error | the control signals for the precharging contactor and the contactor feedback differ; | Yes | ||||||
CH/DCH contactor feedback error | the control signals for the charging/discharging contactor and the contactor feedback differ; | Yes | ||||||
Main contactor feedback error | the control signals for the main contactor and the contactor feedback differ; | Yes | ||||||
General error | ||||||||
High voltage fault | failure of high voltage measuring circuits; | Yes | ||||||
Power switch error | short circuit in contactor coil control circuit or power switch overheating; | Yes | ||||||
HVIL error | breakage of high-voltage interlock current loop; | Yes | ||||||
Precharge error | capacitive load pre-charge process did not end during the estimated time; | |||||||
Power fault | external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices; | Yes | ||||||
Current limit error | charging or discharging current is more than limit calculated by Charge map or Discharge map. |