Configuration
General information
List of input signals
Here is the list of available input signals of BMS Main 3.
Name | Description | Compability | CANopen SDO | Modbus | Abbreviation | ||
Mini S / Mini | Main 2.1 | Main 3 | |||||
Battery cover | a signal from the battery cover; | Battery cover protection | Battery cover protection | Battery cover protection | |||
Charger connected | a signal indicating that charger is connected; | Charge controller | Charge controller | ||||
Power up/down request | a request to power down the device; | Power down controller | |||||
Inhibit charging | a command to open the charging contactor; | ||||||
Inhibit discharging | a command to open the discharging contactor; | ||||||
CH contactor feedback | a signal from charging contactor feedback loop; | Contactor feedback protection | |||||
DCH contactor feedback | a signal from discharging contactor feedback loop; | Contactor feedback protection | |||||
Insulation status | a signal from an insulation monitoring device; | Insulation protection | |||||
Charge request | a request to close the charging contactor; | Charge controller | |||||
Discharge request | a request to close the discharging contactor; | Discharge controller | |||||
PCH contactor feedback | a signal from precharging contactor feedback loop; | Contactor feedback protection | |||||
CH/DCH contactor feedback | a signal from charging/discharging contactor feedback loop; | Contactor feedback protection | |||||
Main contactor feedback | a signal from main contactor feedback loop; | Contactor feedback protection | |||||
Interlock | a signal from interlock loop; | Interlock protection | |||||
Fuse 1, Fuse 2, Fuse 3 | signals from fuses; | ||||||
Circuit breaker status | status of protection disconnector; | ||||||
Balancing request | a request to balance the cells; | Cell balance controller | • | ||||
Close Main contactor | a request to close the main contactor; | Main contactor controller | • (by request) | ||||
Close External 1 | a request to close the External 1 discrete output (if assigned). | External 1 internal state |
List of internal states
Here is the list of available internal states of BMS Main 3.
Name | Abbr. | Description | Set up by | Used by | Output by | |||
Discrete output | Switch | CAN | Modbus | |||||
Low SOC | a signal corresponding the low SOC of the battery; | Low SOC signal controller | • | • | ||||
High charging current | charging current is high; | High charging signal controller | • | • | ||||
Main contactor | state of the main contactor; | Main contactor controller | • | • | ||||
Charging | state of the charging contactor; | Charge controller, Charge/Discharge controller | • | • | ||||
Allow charging | a signal for a charger to start charging; | Charge controller, Charge/Discharge controller | • | • | ||||
Charging current present | the presence of the charging current; | Charging status controller | • | • | ||||
Precharging | state of the precharging contactor; | Precharge controller | • | • | ||||
Discharging | state of the discharging contactor; | Discharge controller, Charge/Discharge controller | • | • | ||||
Discharging current present | the presence of the discharging current; | Discharging status controller | • | • | ||||
Discharging (AUX) | state of the auxiliary discharging contactor; | Discharging (AUX) controller | • | • | ||||
Power down ACK | an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; | Power down controller | • | • | ||||
Charging/discharging | state of the charging/discharging contactor; | Charge/Discharge controller | • | • | ||||
Heater | a command to turn on a heater; | Heater controller | • | • | ||||
Cooler | a command to turn on a cooler; | Cooler controller | • | • | ||||
Balancing 1 | balancing the first series of cells; | Series balancing controller | • | • | ||||
Balancing 2 | balancing the second series of cells; | Series balancing controller | • | • | ||||
Ready to charge | the battery is ready to be charged; | Charging status controller | Charge controller (optionally) | • | • | |||
Ready to discharge | the battery is ready to be discharged; | Discharging status controller | Discharge controller (optionally) | • | • | |||
Power up | an indication of BMS power status; | • | • | |||||
General error | state of the configurable (general) error; | General error protection | ||||||
External 1 | a signal that activates by the remote request. | External 1 input signal |
List of errors
Here is the list of error of BMS Main 3.
Name | Abbr. | Description | Set up by | Is a Critical error? | |
Overcurrent | OC | Overcurrent protection | |||
Undervoltage | UV | Undervoltage protection | |||
Overvoltage | OV | Overvoltage protection | |||
Low temperature (DCH) | LDT | temperature is too low for discharging; | Low temperature protection | ||
High temperature (DCH) | HDT | temperature is too high for discharging; | High temperature protection | ||
Battery cover error | BC | battery cover is open; | Battery cover protection | Yes | |
High humidity | HH | humidity of the battery is increased; | High humidity protection | ||
Water | WA | there is water in the battery enclosure; | Water protection | Yes | |
High Logic temperature | LHT | at least one of the Logic devices is overheated; | Logic high temperature protection | ||
Logic offline | LOF | at least one of the Logic devices is offline; | Logic offline protection | Yes | |
Critical error | CRE | Critical error | |||
Crown error | CRO | connection with a Crown forklift is lost; | |||
Cell count error | CEL | number of cells does not match the specified value; | Cell count protection | Yes | |
HYG offline | HYG | connection with a HYG forklift is lost; | HYG Class I-III truck | ||
Need acknowledge | there is an unacknowledged error in Error journal; | Error journal | |||
Combilift offline | connection with a Combilift forklift is lost; | Combilift truck | |||
Short circuit | Short circuit protection | ||||
High contactor temperature | High contactor temperature protection | ||||
ADC error | current cannot be measured; | Yes | |||
Current sensor error | error in the current sensor circuit; | Current sensor protection | Yes | ||
CH contactor cycles error | switching frequency of the charging contactor is too high; | Charge contactor cycles protection | |||
DCH contactor cycles error | switching frequency of the discharging contactor is too high; | Discharge contactor cycles protection | |||
Shunt offline | connection with the shunt current sensor is lost; | Shunt sensor (CAN bus) | Yes | ||
Shunt error | internal error of the shunt current sensor; | Shunt sensor (CAN bus) | Yes | ||
WDT reset | watchdog timer reset the device; | WDT reset protection | Yes | ||
No temperature sensors | the device has no temperature sensors connected; | Temperature sensors protection | Yes | ||
Temperature sensor is shorted | some temperature sensors are shorted; | Temperature sensors protection | Yes | ||
Spirit offline | connection with a Spirit forklift is lost; | Spirit AGV truck | |||
Low temperature (CH) | temperature is too low for charging; | Low temperature protection | |||
High temperature (CH) | temperature is too high for charging; | High temperature protection | |||
Unallowable charging | charging the battery through the discharging contactor; | Unallowable charging protection | |||
Stuck contactor | Stuck contactor protection | Yes | |||
CH contactor feedback error | the control signals for the charging contactor and the contactor feedback differ; | Contactor feedback protection | Yes | ||
DCH contactor feedback error | the control signals for the discharging contactor and the contactor feedback differ; | Contactor feedback protection | Yes | ||
Insulation fault; | Insulation protection | Yes | |||
PCH contactor feedback error | the control signals for the precharging contactor and the contactor feedback differ; | Contactor feedback protection | Yes | ||
CH/DCH contactor feedback error | the control signals for the charging/discharging contactor and the contactor feedback differ; | Contactor feedback protection | Yes | ||
Main contactor feedback error | the control signals for the main contactor and the contactor feedback differ; | Contactor feedback protection | Yes | ||
General error | General error | ||||
High voltage fault | failure of high voltage measuring circuits; | High voltage controller | Yes | ||
Power switch error | short circuit in contactor coil control circuit or power switch overheating; | Yes | |||
HVIL error | breakage of high-voltage interlock current loop; | HVIL protection | Yes | ||
Precharge error | capacitive load pre-charge process did not end during the estimated time; | Precharge controller | |||
Power fault | external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices; | Yes | |||
Current limit error | charging or discharging current is more than limit calculated by Charge map or Discharge map. | Charge current limit protection, Discharge current limit protection |