Battery controllers: signals, states and errors

Version 28.7 by Admin on 2025/02/06 16:59

Signals, states and errors

Input signals

Below is the list of input signals that can be assigned to discrete inputs of the BMS controller.

  • Remote control values: Off = 0, On = 1, Use physical input = 2-65535.
  • Status values: Off = 0, On = 1.
NameDescriptionCompatibilityBMS DisplayRemote controlStatus
Mini S / MiniMain 2.1Main 3Short nameAbbr.CANopen SDOModbusCANopen SDOModbus
Balancing requestRequest to balance the cellsYesYesYesBalancing req.BR0x5100, sub 0x140x51130x4030 sub 0x00, bit 30x2000, bit 3
Battery coverSignal from the battery coverYesYesYesBattery coverCVR0x5100, sub 0x010x51000x4030 sub 0x00, bit 00x2000, bit 0
CH contactor feedbackSignal from the charging contactor feedback loopYes*YesYesCH cont. feed.CCF0x5100, sub 0x060x51050x4030 sub 0x00, bit 50x2000, bit 5
CH/DCH contactor feedbackSignal from the charging/discharging contactor feedback loopYes*YesYesC/D cont. feed.CDF0x5100, sub 0x0D0x510C0x4030 sub 0x00, bit 120x2000, bit 12
Charge requestRequest to close the charging contactorYesYesYesCharge requestCRE0x5100, sub 0x090x51080x4030 sub 0x00, bit 80x2000, bit 8
Charger connectedSignal indicating that the charger is connectedYesYesYesCharger connect.CON0x5100, sub 0x020x51010x4030 sub 0x00, bit 10x2000, bit 1
Circuit breaker statusStatus of protective disconnectorYesYesYesCircuit breakerCBS0x5100, sub 0x130x51120x4030 sub 0x00, bit 20x20F4, bit 2
Close External 1Request to set the External 1 signalYesYesYesClose Ext.1CE10x5100, sub 0x160x51150x4030 sub 0x00, bit 50x20F4, bit 5
Close Main contactorRequest to close the main contactorYesYesYesClose Main cont.CMC0x5100, sub 0x150x51140x4030 sub 0x00, bit 40x20F4, bit 4
DCH contactor feedbackSignal from the discharging contactor feedback loopYes*YesYesDCH cont. feed.DCF0x5100, sub 0x070x51060x4030 sub 0x00, bit 60x2000, bit 6
Discharge requestRequest to close the discharging contactorYesYesYesDischarge req.DRE0x5100, sub 0x0B0x510A0x4030 sub 0x00, bit 100x2000, bit 10
Fuse 1Signal from fuse 1YesYesYesFuse 1F10x5100, sub 0x100x510F0x4030 sub 0x00, bit 150x2000, bit 15
Fuse 2Signal from fuse 2YesYesYesFuse 2F20x5100, sub 0x110x51100x4030 sub 0x00, bit 00x20F4, bit 0
Fuse 3Signal from fuse 3YesYesYesFuse 3F30x5100, sub 0x120x51110x4030 sub 0x00, bit 10x20F4, bit 1
Inhibit chargingCommand to open the charging contactorYesYesYesInhibit charg.ICH0x5100, sub 0x040x51030x4030 sub 0x00, bit 30x2000, bit 3
Inhibit dischargingCommand to open the discharging contactorYesYesYesInhibit disch.IDC0x5100, sub 0x050x51040x4030 sub 0x00, bit 40x2000, bit 4
Insulation statusSignal from an insulation monitoring deviceYesYesYesInsul. statusINS0x5100, sub 0x080x51070x4030 sub 0x00, bit 70x2000, bit 7
InterlockSignal from the interlock loopYesYesYesInterlockINT0x5100, sub 0x0F0x510E0x4030 sub 0x00, bit 140x2000, bit 14
Main contactor feedbackSignal from the main contactor feedback loopYes*YesYesMain cont. feed.MCF0x5100, sub 0x0E0x510D0x4030 sub 0x00, bit 130x2000, bit 13
PCH contactor feedbackSignal from the precharging contactor feedback loopYes*YesYesPCH cont. feed.PCF0x5100, sub 0x0C0x510B0x4030 sub 0x00, bit 110x2000, bit 11
Power up/down requestRequest to power down the deviceYesYesYesPower down req.PDN0x5100, sub 0x030x51020x4030 sub 0x00, bit 20x2000, bit 2
Precharge requestRequest to close the precharging contactorYesYesYesPrecharge req.PRE0x5100, sub 0x0A0x51090x4030 sub 0x00, bit 90x2000, bit 9

* Contactor feedback signals in BMS Mini / BMS Mini S are connected to X1 header and configured in "Signals → MOSFETs → Contactors feedback" section.

Internal signals

Below is the list of internal BMS signals. Most signals can be assigned to discrete outputs and/or relays.

  • Status values: Off = 0, On = 1.
NameDescriptionCompatibilityBMS DisplayStatus
Mini S / MiniMain 2.1Main 3Short nameAbbr.CANopen SDOModbus
Allow chargingCommand for a charger to start chargingYesYesYesAllow chargingACH 0x2009-0x200A, bit 3
Balancing 1Command to balance the first series of cells YesYesBalancing 1BA1 0x2009-0x200A, bit 15
Balancing 2Command to balance the second series of cells YesYesBalancing 2BA2 0x2009-0x200A, bit 16
Cell analysisSignal indicating cell analysis processYes*Yes*Yes*Cell analysisCEA 0x2009-0x200A, bit 14
Charging current presentSignal showing the presence of the charging currentYesYes*YesCH curr. presentCCP 0x2009-0x200A, bit 4
ChargingCommand to control the charging contactorYesYesYesChargingCH 0x2009-0x200A, bit 2
Charging/DischargingCommand to control the charging/discharging contactorYesYesYesCharg./Discharg.C/D 0x2009-0x200A, bit 22
CoolerCommand to control the coolerYesYesYesCoolerCOO 0x2009-0x200A, bit 9
Crown EWS Yes*Yes*Yes*Crown EWSEWS 0x2009-0x200A, bit 19
Discharging (AUX)Command to control the auxiliary discharging contactorYesYesYesDisch. AUXAUX 0x2009-0x200A, bit 17
Discharging current presentSignal showing the presence of the discharging currentYesYes*YesDCH cur. presentDCP 0x2009-0x200A, bit 6
DischargingCommand to control the discharging contactorYesYesYesDischargingDCH 0x2009-0x200A, bit 5
External 1Command to control an external schemeYesYesYesExternal 1EX1 0x2009-0x200A, bit 26
Heater (AUX)Command to control the auxiliary heater Yes Heater (AUX)HAU 0x2009-0x200A, bit 27
HeaterCommand to control the heaterYesYesYesHeaterHEA 0x2009-0x200A, bit 8
High charging currentSignal indicating that the charging current is highYesYesYesHigh ch. curr.HCC 0x2009-0x200A, bit 1
InitSignal showing that the device is in the initialization phaseYes*Yes*Yes*InitINI 0x2009-0x200A, bit 11
Low SOCSignal indicatiing that the battery has low SOCYesYesYesLow SOCLOS 0x2009-0x200A, bit 0
Main contactorCommand to control the main contactorYesYesYesMain contactorMCO 0x2009-0x200A, bit 20
Power down ACKCommand that acknowledges the BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on the power down requestYesYesYesPower down ACKPDA 0x2009-0x200A, bit 18
Power upSignal indicating the BMS power statusYesYesYesPower upPUP 0x2009-0x200A, bit 25
PrechargingCommand to control the precharging contactorYesYesYesPrechargingPCH 0x2009-0x200A, bit 12
Ready to chargeSignal showing that the battery is ready for chargingYesYesYesReady to chargeRTC 0x2009-0x200A, bit 23
Ready to dischargeSignal showing that the battery is ready for dischargingYesYesYesReady to disch.RTD 0x2009-0x200A, bit 24
Service resetCommand to restart the deviceYes*Yes*Yes*Service resetSR 0x2009-0x200A, bit 21
Shutdown request (Combilift)Command to open the dischrging contactor from the Combilift truckYes*Yes*Yes*Combilift shutd.CSH 0x2009-0x200A, bit 13
Shutdown request (HYG/Spirit)Command to open the dischrging contactor from the HYG truckYes*Yes*Yes*HYG shutdownHSH 0x2009-0x200A, bit 10
Voltage too high for chargingSignal indicating that the battery is fully chargedYes*Yes*Yes*Volt. too highVTH 0x2009-0x200A, bit 7

* Cannot be assigned to discrete outputs and relays.

Errors

Below is the list of BMS errors. General error can be assigned to discrete output.

  • Status values: Off = 0, On = 1.
Name DescriptionIs a critical error?CompatibilityBMS DisplayCANopen SDO, r/oModbus
Mini S / MiniMain 2.1Main 3Short nameAbbr.
ADC errorError of the ADC that measures the battery currentYesYesYesYesADC errorADC 0x2007-0x2008, bit 19. Off = 0, On = 1.
Battery cover errorBattery cover is openYesYesYesYesBattery coverBCE 0x2007-0x2008, bit 5. Off = 0, On = 1.
Cell count errorNumber of cells does not match the specified valueYesYesYesYesCell countCEL 0x2007-0x2008, bit 12. Off = 0, On = 1.
CH contactor cycles errorSwitching frequency of the charging contactor is too high YesYesYesCH cont. cycleCCC 0x2007-0x2008, bit 21. Off = 0, On = 1.
CH contactor feedback errorThe control signal for the charging contactor and the contactor feedback differYes YesYesCH cont. feed.CCF 0x200E-0x200F, bit 6. Off = 0, On = 1.
CH/DCH contactor feedback errorThe control signal for the charging/discharging contactor and the contactor feedback differYes YesYesC/D cont. feed.CDF 0x200E-0x200F, bit 10. Off = 0, On = 1.
Combilift offlineConnection with the Combilift forklift is lost YesYesYesCombilift offl.COM 0x2007-0x2008, bit 15. Off = 0, On = 1.
Contactor feedback errorFailure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device Yes  Cont. feed. er.CFE 0x200E-0x200F, bit 12. Off = 0, On = 1.
Critical errorCritical system error, the BMS is damaged YesYesYesCritical errorCER 0x2007-0x2008, bit 10. Off = 0, On = 1.
Crown errorConnection with the Crown forklift is lost YesYesYesCrown errorCRO 0x2007-0x2008, bit 11. Off = 0, On = 1.
Current limit errorCharging or discharging current is more than the limit calculated by Charge map or Discharge map Yes YesCur. limit errorCLE 0x200E-0x200F, bit 19. Off = 0, On = 1.
Current sensor errorError in the current sensor circuitYesYesYesYesCurrent sensorCSE 0x2007-0x2008, bit 20. Off = 0, On = 1.
DCH contactor cycles errorSwitching frequency of the discharging contactor is too high YesYesYesDCH cont. cycleDCC 0x2007-0x2008, bit 22. Off = 0, On = 1.
DCH contactor feedback errorThe control signal for the discharging contactor and the contactor feedback differYes YesYesDCH cont. feed.DCF 0x200E-0x200F, bit 7. Off = 0, On = 1.
FS errorSD card read/write error YesYesYesFS errorFSE 0x200E-0x200F, bit 3. Off = 0, On = 1.
General errorSpecial configurable error depending on other errors Yes*Yes*Yes*General errorGE 0x200E-0x200F, bit 13. Off = 0, On = 1.
High contactor temperatureTemperature of a contactor is too high YesYesYesHi. cont. temp.HCT 0x2007-0x2008, bit 17. Off = 0, On = 1.
High humidityIncreased humidity inside the battery  YesYesHigh humidityHHU 0x2007-0x2008, bit 6. Off = 0, On = 1.
High Logic temperatureAt least one of the Logic devices is overheated  YesYesHi. Logic temp.HLT 0x2007-0x2008, bit 8. Off = 0, On = 1.
High temperature (CH)Temperature is too high for charging YesYesYesHigh temp. CHHTC 0x200E-0x200F, bit 1. Off = 0, On = 1.
High temperature (DCH)Temperature is too high for discharging YesYesYesHigh temp. DCHHTD 0x2007-0x2008, bit 4. Off = 0, On = 1.
High voltage faultFailure of high voltage measuring circuitsYes  YesHV faultHVF 0x200E-0x200F, bit 14. Off = 0, On = 1.
HVIL errorBreakage of high-voltage interlock current loopYes  YesHVIL errorHE 0x200E-0x200F, bit 16. Off = 0, On = 1.
HYG offlineConnection with the HYG forklift is lost YesYesYesHYG offlineHYG 0x2007-0x2008, bit 13. Off = 0, On = 1.
Insulation faultInsulation resistance is too lowYesYesYesYesInsulation faultINF 0x200E-0x200F, bit 8. Off = 0, On = 1.
Logic count errorThe number of BMS Logic devices differs from the required value  YesYesLogic countLOG 0x2007-0x2008, bit 18. Off = 0, On = 1.
Logic offline (Cell monitor offline)BMS Main devices: at least one of the Logic devices is offline.
BMS Mini devices: connection with cell monitor is lost.
YesYesYesYesLogic offlineLOF 0x2007-0x2008, bit 9. Off = 0, On = 1.
Low temperature (CH)Temperature is too low for charging; YesYesYesLow temp. CHLTC 0x200E-0x200F, bit 0. Off = 0, On = 1.
Low temperature (DCH)Temperature is too low for discharging; YesYesYesLow temp. DCHLTD 0x2007-0x2008, bit 3. Off = 0, On = 1.
Main contactor feedback errorThe control signal for the main contactor and the contactor feedback differYes YesYesMain cont. feed.MCF 0x200E-0x200F, bit 11. Off = 0, On = 1.
Mount errorSD card cannot be mounted YesYesYesMount errorMNT 0x200E-0x200F, bit 2. Off = 0, On = 1.
Need acknowledgeThere is an unacknowledged error in error journal YesYesYesNeed ACKACK 0x2007-0x2008, bit 14. Off = 0, On = 1.
No temperature sensorsThe device has no temperature sensors connectedYesYesYesYesNo temp. sens.NTS 0x2007-0x2008, bit 27. Off = 0, On = 1.
OvercurrentThe battery current is too high YesYesYesOvercurrentOC 0x2007-0x2008, bit 0. Off = 0, On = 1.
OvervoltageVoltage of any cell is too high YesYesYesOvervoltageOV 0x2007-0x2008, bit 2. Off = 0, On = 1.
PCH contactor feedback errorThe control signal for the precharging contactor and the contactor feedback differYes YesYesPCH cont. feed.PCF 0x200E-0x200F, bit 9. Off = 0, On = 1.
Power faultExternal devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devicesYes  YesPower faultPF 0x200E-0x200F, bit 18. Off = 0, On = 1.
Power switch errorShort circuit in contactor coil control circuit or power switch overheatingYes  YesPSW errorPSE 0x200E-0x200F, bit 15. Off = 0, On = 1.
Precharge errorCapacitive load pre-charge process did not end during the estimated time YesYesYesPrecharge errorPE 0x200E-0x200F, bit 17. Off = 0, On = 1.
Settings errorWrong checksum of the device settings  Yes Settings err.SET 0x2007-0x2008, bit 25. Off = 0, On = 1.
Short circuitFlowing high battery currents during a long time YesYesYesShort circuitSHC 0x2007-0x2008, bit 16. Off = 0, On = 1.
Shunt errorInternal error of the shunt current sensorYesYesYesYesShunt errorSHE 0x2007-0x2008, bit 24. Off = 0, On = 1.
Shunt offlineConnection with the shunt current sensor is lostYesYesYesYesShunt offlineSHO 0x2007-0x2008, bit 23. Off = 0, On = 1.
Spirit offlineConnection with the Spirit forklift is lost YesYesYesSpirit offlineSPI 0x2007-0x2008, bit 29. Off = 0, On = 1.
Stuck contactorSome contactor got stuckYesYesYesYesStuck contactorSTC 0x200E-0x200F, bit 5. Off = 0, On = 1.
Temperature sensor is shortedSome temperature sensors are shortedYesYesYesYesShorted temp.TSS 0x2007-0x2008, bit 28. Off = 0, On = 1.
Unallowable chargingCharging the battery through the discharging contactor YesYesYesUnallowable CHUCH 0x200E-0x200F, bit 4. Off = 0, On = 1.
UndervoltageVoltage of any cell is too low YesYesYesUndervoltageUV 0x2007-0x2008, bit 1. Off = 0, On = 1.
WaterThere is water in the battery enclosureYes YesYesWaterWHU 0x2007-0x2008, bit 7. Off = 0, On = 1.
WDT resetWatchdog timer reset the deviceYesYesYesYesWDT resetWDT 0x2007-0x2008, bit 26. Off = 0, On = 1.

* The signal can be assigned to discrete outputs and relays.